44A111X SPECIFICATION CONTROL DRAWING TITLE Date Revision ONE CONDUCTOR CABLE, SHIELDED, JACKETED, GENERAL PURPOSE, 600 VOLT 4-1-11 G This specification sheet forms a part of the latest issue of Raychem Specification 44. SHIELD - COPPER, COATING SAME AS ON CONDUCTOR EXCEPT TIN-COATED SHIELD WITH SILVER-COATED COMPONENT WIRE - 44A011X JACKET - RADIATION-CROSSLINKED, HIGH-STRENGTH ALLOY CONDUCTOR MODIFIED PVDF TABLE I. CABLE CONSTRUCTION DETAILS JACKET THICKNESS OUTSIDE DIAMETER CONDUCTOR SHIELD MAXIMUM PART NUMBER (in.) (in.) SIZE SIZE WEIGHT 1/ (AWG) (AWG) (lbs/1000 ft.) MINIMUM NOMINAL NOMINAL MAXIMUM 44A111X-26-* 26 38 .005 .007 .065 .070 4.6 44A111X-24-* 24 38 .005 .007 .072 .077 5.8 44A111X-22-* 22 38 .005 .007 .079 .084 7.2 44A111X-20-* 20 38 .006 .008 .089 .094 9.9 44A111X-18-* 18 36 .006 .008 .103 .108 13.9 44A111X-16-* 16 36 .006 .008 .110 .115 16.5 44A111X-14-* 14 36 .006 .008 .127 .132 22.9 44A111X-12-* 12 36 .006 .008 .146 .151 32.1 44A111X-10-* 10 36 .006 .008 .166 .179 44.3 TABLE II. CABLE PERFORMANCE DETAILS BEND TESTING MANDREL DIAMETER WEIGHT PART NUMBER (inch) (3%) (lb) (3%) 1/ LIFE CYCLE, IMMERSION COLD LIFE CYCLE, IMMERSION COLD AND ACCELERATED AGING BEND AND ACCELERATED AGING BEND 44A111X-26-* 3.00 3.00 .125 .750 44A111X-24-* 3.00 3.00 .188 .750 44A111X-22-* 3.00 3.00 .188 1.50 44A111X-20-* 3.00 3.00 .188 1.50 44A111X-18-* 3.00 3.00 .250 1.50 44A111X-16-* 3.00 3.00 .250 1.50 44A111X-14-* 6.00 6.00 .500 4.50 44A111X-12-* 6.00 6.00 .500 4.50 44A111X-10-* 6.00 6.00 .500 4.50 NOTE: Nominal values are for information only. Nominal values are not requirements. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. The TE logo, TE Connectivity and Raychem are trademarks. Raychem Wire & Cable 501 Oakside Avenue DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. Redwood City, CA 94063-3800 Page 1 of 1 Phone: 1-800-227-8816 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 2011 Tyco Electronics Corporation. All rights reserved.Revision SCD Page 2 of 2 G SPECIFICATION CONTROL DRAWING 44A111X CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level ACCELERATED AGING: 300 3C for 6 hours BLOCKING: 150 3C for 6 hours DIELECTRIC WITHSTAND: 2500 volts (rms), 60 Hz, 1 minute FLAMMABILITY: 30 seconds (maximum) 3 in. (maximum) no flaming of facial tissue IMMERSION: Diameter increase 5% (maximum), no cracking, no dielectric breakdown JACKET COLOR: White preferred JACKET CONCENTRICITY: 70% (minimum) JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 200% (minimum) Tensile Strength, 4000 lbf/in (minimum) JACKET FLAWS: Spark Test, 1.5 kV (rms) Impulse Dielectric Test, 6.0 kV (peak) LIFE CYCLE: 200 3C for 168 hours LOW TEMPERATURE-COLD BEND: -65 2C for 4 hours SHIELD COVERAGE: 85% (minimum) VOLTAGE WITHSTAND (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute PART NUMBER: The in the part numbers on page 1 shall be replaced by the applicable conductor material designator as follows: 1 tin-coated copper 2 silver-coated copper 3 nickel-coated copper 4 silver-coated high-strength copper alloy (AWG s 26 - 16 only) 6 nickel-coated high-strength copper alloy (AWG s 26 - 20 only) The in the part numbers on page 1 shall be replaced by color code designators with a dash separating the component wire color from the jacket color. 1/ Example: AWG 20, tin-coated copper wire, white component wire white jacket: 44A1111-20-9-9 1/ See footer section on page 1