44A412X SPECIFICATION CONTROL DRAWING TITLE TWO CONDUCTOR CABLE, JACKETED, LIGHTWEIGHT, Date Revision 05-08-04 E GENERAL PURPOSE, 600 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 44 COMPONENT WIRES - 44A011X JACKET - RADIATION-CROSSLINKED, MODIFIED PVF 2 TABLE I. CABLE CONSTRUCTION DETAILS JACKET THICKNESS OUTSIDE DIAMETER MAXIMUM CONDUCTOR (in.) PART NUMBER (in.) WEIGHT SIZE (lb/1000 ft) 1/ (AWG) MINIMUM NOMINAL NOMINAL MAXIMUM 44A412X-26-* 26 .005 .007 .082 .087 4.3 44A412X-24-* 24 .005 .007 .094 .099 6.0 44A412X-22-* 22 .005 .007 .108 .114 8.4 .007 .124 .130 12.0 44A412X-20-* 20 .005 44A412X-18-* 18 .005 .007 .144 .150 17.4 44A412X-16-* 16 .005 .007 .158 .165 21.7 44A412X-14-* 14 .005 .007 .192 .199 33.1 44A412X-12-* 12 .006 .008 .232 .240 51.0 TABLE II. CABLE PERFORMANCE DETAILS BEND TESTING WEIGHT MANDREL DIAMETER (lb) ( 3%) (inch) ( 3%) PART NUMBER ACCELERATED AGING ACCELERATED AGING 1/ COLD COLD IMMERSION AND IMMERSION AND BEND BEND LIFE CYCLE LIFE CYCLE 44A412X-26-* 3.00 3.00 .250 1.50 3.00 3.00 .375 1.50 44A412X-24-* 44A412X-22-* 3.00 3.00 .375 3.00 .375 3.00 44A412X-20-* 3.00 3.00 44A412X-18-* 6.00 6.00 .500 3.00 44A412X-16-* 6.00 6.00 .500 3.00 6.00 6.00 1.00 9.00 44A412X-14-* 44A412X-12-* 6.00 6.00 1.00 9.00 NOTE: Nominal values are for information only. Nominal values are not requirements. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. RR RRR Wire & Cable DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. 501 Oakside Avenue Redwood City, CA 94063-3800 Page 1 of 2 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Phone: 1-800-227-8816 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Fax: 1-650-361-6297SCD Number SPECIFICATION CONTROL DRAWING Page 2 of 2 44A412X WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level ACCELERATED AGING: 225 2C for 6 hours. BLOCKING: 150 3C for 6 hours DIELECTRIC WITHSTAND: 2500 volts (rms), 60 Hz, 1 minute FLAMMABILITY: 30 seconds (maximum) 3 in. (maximum) no flaming of facial tissue. JACKET COLOR: White preferred JACKET CONCENTRICITY: 70% (minimum) JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 200% (minimum) 2 Tensile strength, 4000 lbf/in (minimum) LIFE CYCLE: 200 3C for 168 hours LOW TEMPERATURE-COLD BEND: -65 2C for 4 hours PART NUMBER The in the part numbers on page 1 shall be replaced by the applicable conductor material designators as follows: 1 tin-coated copper 2 silver-coated copper 3 nickel-coated copper 4 silver-coated high strength copper alloy (AWG s 26 - 16 only) 6 nickel-coated high strength copper alloy (AWG s 26 - 20 only) The in the part numbers on page 1 shall be replaced by color code designators with a slash separating the component wire colors and a dash separating the component wire colors from the jacket color. 1/ Example: 20 Awg, tin-coated copper wires, black and brown component wires white jacket: 44A4121-20-0/1-9 1/ See footer section on page 1