44B5121 SPECIFICATION CONTROL DRAWING Date Revision TITLE TWO CONDUCTOR CABLE, SPIRALLY SHIELDED, JACKETED, GENERAL PURPOSE, 600 VOLT 4-20-07 H This specification sheet forms a part of the latest issue of Raychem Specification 55A. JACKET - RADIATION-CROSSLINKED, SHIELD - TIN-COATED COPPER COMPONENT WIRES - 44A0111 MODIFIED ETFE CABLE CONSTRUCTION DETAILS JACKET THICKNESS OUTSIDE DIAMETER CONDUCTOR SHIELD MAXIMUM PART NUMBER (in.) (in.) SIZE SIZE WEIGHT 1/ (AWG) (AWG) (lbs/1000 ft.) MINIMUM NOMINAL NOMINAL MAXIMUM 44B5121-24-* 24 36 .006 .008 .107 .112 9.5 44B5121-22-* 22 36 .006 .008 .121 .127 12.4 44B5121-20-* 20 36 .006 .008 .137 .144 16.4 44B5121-18-* 18 36 .006 .008 .157 .165 22.4 44B5121-16-* 16 36 .006 .008 .171 .180 27.1 44B5121-14-* 14 36 .006 .008 .205 .215 39.3 44B5121-12-* 12 36 .007 .009 .245 .257 58.0 CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C LIFE CYCLE: 200 3C for 168 hours Maximum continuous conductor temperature LOW TEMPERATURE-COLD BEND: -65 2C for 4 hours VOLTAGE RATING: 600 volts (rms) at sea level SHIELD COVERAGE: 85% (minimum) ACCELERATED AGING: 300 3C for 7 hours VOLTAGE WITHSTAND TEST (Post Environmental): BLOCKING: 150 3C for 6 hours 1000 volts (rms), 60 Hz, 1 minute DIELECTRIC WITHSTAND: 2500 volts (rms), 60 Hz, 1 minute FLAMMABILITY (Procedure 1): 3 seconds (maximum) PART NUMBER: 3 in. (maximum) no flaming of facial tissue The * in the part numbers above shall be replaced by color code JACKET COLOR: White preferred designators with a slash separating the component wire colors and a JACKET ELONGATION AND TENSILE STRENGTH: dash separating the component wire colors from the jacket color. Elongation, 50% (minimum) Tensile Strength, 5000 lbf/in (minimum) 1/ Example: AWG 20, black and brown component wires white jacket: JACKET FLAWS: 44B5121-20-0/1-9 Spark Test, 1.0 kV (rms) Impulse Dielectric Test, 6.0 kV (peak) NOTE: Nominal values are for information only. Nominal values are not requirements. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. R Wire & Cable DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL 501 Oakside Avenue Redwood City, CA 94063-3800 Page 1 of 1 Phone: 1-800-227-8816 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 2007 Tyco Electronics Corporation. All rights reserved.