55/0112 SPECIFICATION CONTROL DRAWING TITLE Date Revision WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED, 4-30-13 H LIGHTWEIGHT, GENERAL PURPOSE, OUTER SPACE, 600 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 55/. INSULATION - LOW OUTGASSING, CONDUCTOR - SILVER-COATED COPPER RADIATION-CROSSLINKED, MODIFIED ETFE TABLE I. CONSTRUCTION DETAILS DIAMETER OF FINISHED WIRE STRANDED WIRE CONDUCTOR MAXIMUM PART NUMBER MAXIMUM CONDUCTOR SIZE STRANDING RESISTANCE DIAMETER 1/ WEIGHT (in.) (AWG) (number x AWG) AT 20C (in.) (lbs/1000 ft.) MINIMUM MAXIMUM (ohms/1000 ft) 55/0112-30-* 30 7 x 38 .011 .012 100.7 .024 .002 .66 55/0112-28-* 28 7 x 36 .014 .015 63.8 .027 .002 .91 55/0112-26-* 26 19 x 38 .018 .019 38.4 .032 .002 1.4 55/0112-24-* 24 19 x 36 .023 .025 24.3 .037 .002 2.0 55/0112-22-* 22 19 x 34 .029 .030 15.1 .043 .002 2.8 55/0112-20-* 20 19 x 32 .037 .039 9.19 .050 .002 4.3 55/0112-18-* 18 19 x 30 .046 .048 5.79 .060 .002 6.5 55/0112-16-* 16 19 x 29 .052 .054 4.52 .068 .002 8.3 55/0112-14-* 14 19 x 27 .065 .068 2.88 .085 .003 13.0 55/0112-12-* 12 37 x 28 .084 .087 1.90 .103 .003 19.7 55/0112-10-* 10 37 x 26 .106 .112 1.19 .128 .006 32.3 55/0112-8-* 8 133 x 29 .158 .169 .658 .188 .008 60.5 TABLE II. PERFORMANCE DETAILS BEND TESTING PART NUMBER MANDREL DIAMETER WEIGHT 1/ (inch) ( 3%) (lb) ( 3%) CROSSLINKED VERIFICATION CROSSLINKED VERIFICATION 55/0112-30-* .250 .125 55/0112-28-* .250 .125 55/0112-26-* .375 .125 55/0112-24-* .375 .250 55/0112-22-* .500 .375 55/0112-20-* .500 .500 55/0112-18-* .500 .500 55/0112-16-* .750 .750 55/0112-14-* 1.00 1.00 55/0112-12-* 1.50 1.50 55/0112-10-* 2.00 1.50 55/0112-8-* 3.00 4.00 Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER. AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. Raychem Wire & Cable 501 Oakside Avenue DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. Redwood City, CA 94063-3800 Page 1 of 2 Phone: 1-800-227-8816 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 2010-2013 Tyco Electronics Corporation,. All rights reserved.Revision SCD Number Page 2 of 2 H SPECIFICATION CONTROL DRAWING 55/0112 WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 200C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level COLOR: White preferred CROSSLINKED VERIFICATION: 300 3C for 1 hour IDENTIFICATION AND COLOR STRIPING DURABILITY: 125 cycles (250 strokes) (minimum), 500 g weight INSULATION ELONGATION 50% (minimum) INSULATION FLAWS: Spark Test, 3.0 kV (rms) Impulse Dielectric Test, 8.0 kV (peak) INSULATION THICKNESS: 0.005 in. (minimum) RADIATION RESISTANCE: 500 megarads SHRINKAGE: 230 3C for 1 hour, 0.125 in. (maximum) in 12 inches VACUUM STABILITY: Total Mass Loss (TML), 1.00% (maximum) Volatile Condensable Material, 0.10% (maximum) VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz, 5 minutes PART NUMBER: The in the part numbers on page 1 shall be replaced by a color code designator. 1/ Example: AWG 22, White: 55/0112-22-9 AWG 22, White with black stripe: 55/0112-22-90 1/ See footer section on page 1