55/0114 SPECIFICATION CONTROL DRAWING Date Revision TITLE WIRE, RADIATION-CR0SSLINKED, MODIFIED ETFE INSULATED, E 2-28-05 LIGHTWEIGHT, OUTER SPACE, 600 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 55/. JACKET - LOW OUTGASSING, CONDUCTOR - SILVER-COATED HIGH STRENGTH COPPER ALLOY RADIATION-CROSSLINKED, MODIFIED ETFE TABLE I. CONSTRUCTION DETAILS FINISHED WIRE DIAMETER OF STRANDED WIRE CONDUCTOR MAXIMUM MAXIMUM PART NUMBER CONDUCTOR RESISTANCE SIZE STRANDING DIAMETER WEIGHT (in.) 1/ (AWG) (number x AWG) AT 20C (in.) (lb/1000 ft) (ohms /1000 ft.) MINIMUM MAXIMUM 55/0114-30-* 30 7 x 38 .011 .012 117.4 .024 .002 .66 7 x 36 55/0114-28-* 28 .014 .016 74.4 .027 .002 .91 26 19 x 38 .018 .020 44.8 .032 .002 1.4 55/0114-26-* 55/0114-24-* 24 19 x 36 .023 .025 28.4 .037 .002 2.0 19 x 34 .043 .002 55/0114-22-* 22 .029 .031 17.5 2.9 20 19 x 32 .037 .039 10.7 .050 .002 4.4 55/0114-20-* 55/0114-18-* 18 19 x 30 .046 .050 6.8 .060 .002 6.5 16 19 x 29 .052 .057 5.3 .068 .002 8.3 55/0114-16-* TABLE II. PERFORMANCE DETAILS BEND TESTING WEIGHT MANDREL DIAMETER (lb) ( 3%) (inch) ( 3%) PART NUMBER 1/ CROSSLINK VERIFICATION CROSSLINK VERIFICATION .125 55/0114-30-* .250 55/0114-28-* .125 .250 55/0114-26-* .375 .125 .250 55/0114-24-* .375 55/0114-22-* .500 .375 .500 55/0114-20-* .500 55/0114-18-* .500 .500 55/0114-16-* .750 .750 WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 200C RADIATION RESISTANCE: 500 megarads Maximum continuous conductor temperature SHRINKAGE: 230 3C for 1 hour, 0.125 in. (maximum) in 12 in. VOLTAGE RATING: 600 volts (rms) at sea level VACUUM STABILITY: CROSSLINK VERIFICATION: 300 3C for 1 hour Total Mass Loss (TML), 1.0% (maximum) COLOR: White preferred Volitale Condensable Material, 0.1% (maximum) IDENTIFICATION AND COLOR STRIPING DURABILITY: VOLTAGE WITHSTAND TEST (Post Environmental): 125 cycles (250 strokes) (minimum), 500 g weight 2500 volts (rms), 60 Hz, 5 minutes INSULATION ELONGATION: 50% (minimum) INSULATION FLAWS: PART NUMBER: Spark Test, 3.0 kV (rms) The in the part numbers above shall be replaced by color Impulse Dielectric Test, 8.0 kV (peak) code designators. INSULATION THICKNESS: .005 in. (minimum) 1/ Example: AWG 20, white: 55/0114-20-9 Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL R Wire & Cable REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. 501 Oakside Avenue Redwood City, CA 94063-3800 DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. Phone: 1-800-227-8816 Page 1 of 1 Fax: 1-650-361-6297 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. ReviewX-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Multi-Conductor Cables category: Click to view products by TE Connectivity manufacturer: Other Similar products are found below : 89182-010-1000 89705-008-500 89842-002-1000 6000FE-877-1000 6120UL-002-1000 CS2885-000 M27500-20SP2S23 6300FE-877- U1000 6309UE-877-1000 M3905-BK005 6502FE 8771000 6541PA-008-U1000 CV6807-000 CW9530-000 CX6543-000 CXA-0066-20-4- 9CS2973 CXA-0078-16-1-9CS2405 CXA-0078-22-4-9CS2405 CXA-0078-24-4-9CS2405 CXA-0140-16-6/9-9CS2405 CY0660-000 720451-000 752687-000 768146-000 773159-000 82841-877-5000 83318E-009-500 8348-060-500 83559-002-1000 83653-002-5000 83659-002-1000 83709-002-1000 8404-060-500 8469 060100 858171-000 8628-060-500 868361-001 8730-060-1000 8737-060-U1000 8747-060-100 8747-060-1000 8769-060-1000 8775-060-500 8780-060-1000 8782-001-U1000 88444-002-1000 9159-060-500 9318-060- 1000 939870-000 9423 060U500