Catalog 1308242 Issued 3-03 (PDF Rev. 10-07) AGASTAT 7000 series Industrial Electropneumatic Timing Relay File E15631 File LR29186 Note:7032 types and certain models with accessories are not agency approved. Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to confirm the product meets the requirements for a given application. Consult factory for ordering information. Design Features On-delay model 7012 (delay on pickup) Available in on-delay, true off-delay, and on/off-delay. Applying continuous voltage to the coil Timing from 0.1 seconds to 60 minutes, in linear increments. (L1-L2) starts a time delay lasting for Oversize time-calibrated adjustment knobs, serrated with high-resolution the preset time. During this period the markings visible from all angles makes the timer easy to set timers. normally closed contacts (3-5 and 4-6) Inherent transient immunity. remain closed. At the end of the delay Standard voltages from 6-550VAC and 12-550VDC (special voltages available.) period the normally closed contacts Available in 2-pole or 4-pole models. break and the normally open contacts Numerous enclosure options: explosion proof, dust tight, watertight, (1-5 and 2-6) make. The contacts re- hermetically-sealed, NEMA 1. main in this transferred position until Auxiliary timed and instantaneous switches can be added for greater switching the coil is deenergized, at which time flexibility. the switch instantaneously returns to Many mounting options: Surface mount, Panel mount, Octal plug-in mounting. its original position. Options: quick-connect terminals, dial stops, and transient protection module. De-energizing the coil, either during Easy-to-reach screw terminals, all on the face of the unit, clearly identified. or after the delay period, will recycle Modular assembly - timing head, coil assembly and switchblock are all the unit within 50 msec. individual modules, with switches field-replaceable. It will then provide a full delay period upon re-energization, regardless of Design & Construction how often the coil voltage is interrupt- ed before the unit has been permitted There are three main components of Series 7000 Timing Relays: totime-ou to its full delay setting. Calibrated Timing Head uses no needle valve, recirculates air under controlled pressure through a variable orifice to provide linearly adjustable Off-delay model 7022 (delay on dropout) timing. Patented design provides instant recycling, easy adjustment and long service life under severe operating conditions. Applying voltage to the coil (for at Precision-Wound Potted Coil module supplies the initial motive force least 50 msec) will instantaneously with minimum current drain. Total sealing without external leads eliminates transfer the switch, breaking the nor- moisture problems, gives maximum insulation value. mally closed contacts (1-5 and 2-6), Snap-Action Switch Assembly - custom-designed over-center and making the normally open mechanism provides greater contact pressure up to transfer time for contacts (3-5 and 4-6). Contacts positive, no flutter action. Standard switches are DPDT arrangement, with remain in this transferred position as flexible beryllium copper blades and silver-cadmium oxide contacts. Special long as the coil is energized. Thetiming-dut design assures positive wiping action, sustained contact pres- time delay begins immediately upon sure and greater heat dissipation during long delay periods. de-energization. At the end of the de- Each of these subassemblies forms a self-contained module which is lay period the switch returns to its then assembled at the factory with the other two to afford a wide choice of normal position. operating types, coil voltages, and timing ranges. Re-energizing the coil during the The squared design with front terminals and rear mounting permits the delay period will immediately return grouping of Series 7000 units side-by-side in minimum panel space. the timing mechanism to a point Auxiliary switches may be added in the base of the unit, without affecting where it will provide a full delay the overall width or depth. period upon subsequent de- energization. The switch remains in Operation the transferred position. Two basic operating types are available. To increase the versatility of the basic timer models, auxiliary switches may On-Delay models provide a delay period on energization, at the end of be added to either on-delay or off-delay types. They switch additional circuits, which the switch transfers the load from one set of contacts to another. De- provide two-step timing action, or furnish electrical interlock for sustained coil energizing the unit during the delay period immediately recycles the unit, energization from a momentary impulse, depending on the type selected and readying it for another full delay period on re-energization. its adjustment. Because of their simple attachment and adjustment features, InOff-Dela models the switch transfers the load immediately upon they can be installed at the factory or in the field, by any competent mechanic. energization, and the delay period does not begin until the unit is de- All auxiliary switches are SPDT with UL listings of 10A 125, 250, or 480 energized. At the end of the delay period the switch returns to its original po- VAC. A maximum of one Code T or two Code L auxiliary switches may be sition. Re-energizing the unit during the delay period immediately resets the added to each relay. The L or LL switch is available with on-delay relays only. timing, readying it for another full delay period on de-energization. No power The T switch is available with both the on-delay and off-delay relays. is required during the timing period. Auxiliary Switch Options for On-Delay In addition to these basic operating types,Double-Hea models offer Instant Transfer (Auxiliary Switch Code L, sequential delays on pull-in and drop-out in one unit. With the addition of maximum of 2 per relay.) auxiliary switches the basic models provide two-step timing, pulse actuation 1. Energizing coil begins time delay and transfers auxiliary switch. for interlock circuits, or added circuit capacity. 2. Main switch transfers after total preset delay. 3. De-energizing coil resets both switches instantly. Auxiliary switch is nonadjustable. NOTE: Seismic & radiation tested E7000 models are available. Two-Step Timing (Auxiliary Switch Code T, Consult factory for detailed information. maximum of 1 per relay.) Dimensions are shown for Dimensions are in inches over Specifications and availability www.tycoelectronics.com reference purposes only. (millimeters) unless otherwise subject to change. Technical support: 1248 specified. Refer to inside back cover.Catalog 1308242 Issued 3-03 (PDF Rev. 10-07) AGASTAT Auxiliary switch options To increase the versatility of the basic timer models, auxiliary switches may 4. De-energizing coil resets both switches instantly. First delay is be added to either on-delay or off-delay types. They switch additional circuits, independently adjustable, up to 30% of overall delay. provide two-step timing action, or furnish electrical interlock for sustained coil (Recommended maximum 100 seconds.) energization from a momentary impulse, depending on the type selected and Auxiliary Switch Options for Off-Delay its adjustment. Because of their simple attachment and adjustment features, In these models the same auxiliary switch provides either two-step timing or they can be installed at the factory or in the field, by any competent mechanic. instant transfer action, depending on the adjustment of the actuator. All auxiliary switches are SPDT with UL listings of 10A 125, 250, or 480 VAC. Two-Step Timing (Auxiliary Switch Code T, maximum of 1 per relay.) A maximum of one Code T or two Code L auxiliary switches may be added to 1. Energizing coil transfers main and auxiliary switches instantly. each relay. The L or LL switch is available with on-delay relays only. The T 2. De-energizing coil begins time delay. switch is available with both the on-delay and off-delay relays. 3. After first delay auxiliary switch transfers. Auxiliary Switch Options for On-Delay 4. Main switch transfers after total preset delay. First delay is independently Instant Transfer (Auxiliary Switch Code L, maximum of 2 per relay.) adjustable, up to 30% of overall delay. (Recommended maximum 100 sec- 1. Energizing coil begins time delay and transfers auxiliary switch. onds.) 2. Main switch transfers after total preset delay. Instant Transfer (Auxiliary Switch Code L, maximum of 1 per relay.) 3. De-energizing coil resets both switches instantly. 1. Energizing coil transfers main and auxiliary switches instantly. Auxiliary switch is nonadjustable. 2. De-energizing coil resets auxiliary switch and begins time delay. Two-Step Timing (Auxiliary Switch Code T, maximum of 1 per relay.) 3. Main switch transfers after total preset delay. 1. Energizing coil begins time delay. Auxiliary switch is factory adjusted to give instant transfer operation, but may 2. After first delay auxiliary switch transfers. be easily adjusted in the field to provide two-step timing. 3. Main switch transfers after total preset delay. On-delay, off-delay model 7032 (double head) The Double Head model provides delayed switch transfer on energization of its coil, followed by delayed resetting upon coil de- energization. Each delay period is independently adjustable. In new circuit designs or the improvement of existing controls now using two or more conventional timers, the Double Head unit offers distinct advantages. Its compact design saves precious panel space, while the simplified wiring reduces costly interconnection. Four pole model 7014. 7024 With the addition of an extra switch block at the bottom of the basic unit, this version of the Series 7000 offers four pole switch capacity with simul- taneous timing or two-step timing. The two-step operation is achieved by factory adjustment to your specifications. For two-step operation, a maximum timing ratio between upper and lower switches of 3:2 is recommended. Once adjusted at the factory, this ratio remains constant regardless of changes in dial settings. (Ex: If upper switch transfer is set on dial at 60 sec., minimum time on lower switch should be 40 sec.) This Series 7000 unit offers many of the performance features found in basic models - voltage ranges, timing and switch capacities are virtually iden- tical. Four pole models add approximately 1-1/4 to the maximum height of the basic model, approximately 1/8 to the depth. They are designed for vertical operation only. Surge/transient protection option Features The Surge/Transient Protection Option protects electronic control circuits from Protect electronic control circuits transients and surges which are generated when the timer coil is activated. from voltage transients generated Built with a minimum of moving parts, the unit provides a fast response to rap- by the timer coil. idly rising voltage transients. The accurate, precision-made device is not polari- Fast response to the rapidly rising ty sensitive and permits the user to initiate, delay, sequence and program back E.M.F. equipment actions over a wide range of applications under the most severe High performance clamping voltage operating conditions. characteristics. It consists of a specially modified coil case, varistor, varistor cover, terminal UL recognized, (except varistor and extensions and cup washers so that normal terminations can be used. The coil together). varistor will not affect the operating characteristics of the 7000 Timer. The Timer NOT polarity sensitive. varistor has bilateral and symmetrical voltage and current characteristics and therefore can be used in place of the back-to-back zener diodes. This charac- teristic also means that the coil will not be polarity sensitive. Transient Suppressor Option Dimensions are shown for Dimensions are in inches over Specifications and availability www.tycoelectronics.com reference purposes only. (millimeters) unless otherwise subject to change. Technical support: 1249 specified. Refer to inside back cover.