General Purpose High Power PCB Relays PPottotter & Brumfielder & Brumfield T92 Series Two-pole 30A PCB or Panel Mount Relay n 40A, 2 form A (NO) and 2 form C (CO) switching capability n Designed to control compressor loads to 3.5 tons, 110LRA / 25.3FLA n Meets requirements of UL 508 and UL 873 spacings - 8mm through air, 9.5mm over surface n Meets requirements of VDE 8mm spacing, 4kV dielectric coil-to- contact n Meets requirements of UL Class F construction n UL approved for 600VAC switching (1.5HP) n New screw terminal version (consult factory for availability, ratings) Typical applications HVAC, residential / commercial appliances, industrial controls. 1) Approvals Contact ratings (continued) UL E58304 (Recognized and Listed) CSA LR48471 VDE 40019600 ARI 780-86 Endurance Test (section 6.6): Technical data of approved types on request. HVAC Definite Purpose Contactor Standard Normally Open Contacts Contact Data Single Phase/Two Pole (Both poles together switching a single load) 110 LRA, 25.3 FLA, 200K operations (DC Coil) Contact arrangement 2 form A (NO), 2 form C (CO) Rated voltage 277VAC L1 L2 Max. switching voltage 600VAC Rated current 30A NO 3A NC Figure 1 T1T2 Limiting continuous current 40A NO 3A NC Limiting making current 40A NO 3A NC Limiting breaking current 40A NO 3A NC Single Phase Per Pole (Single load per pole) Contact material AgSnOInO, AgCdO 110 LRA, 18 FLA, 200K operations (DC Coil). Min. recommended contact load 500ma (NO)/ 100ma (NC), 12VAC 60 LRA, 14 FLA, 200K operations (AC Coil). Frequency of operation, with load 360hr L1 L2 Operate/release time max., including bounce 25/25ms Figure 2 T1 T2 1) Contact ratings Type Load Cycles UL508 AgCdO 1) Contact ratings at 25C (unless otherwise noted) with relay properly vented. 3 FLA, LRA ratings are compatible with 3.5 ton compressor applications. NO 40A, 277VAC, resistive 6x10 3 NO 30A, 120/277VAC, resistive 100x10 3 6 NO 10A, 600VAC, general purpose 100x10 Mechanical endurance 10x10 ops. 3 NO 1HP, 120VAC 100x10 3 NO 3HP, 240VAC 1x10 3 NO 1.5HP, 480 or 600VAC 100x10 Coil Data 3 NO 110LRA/25.3FLA, 240VAC (DC coil only) 100x10 Coil voltage range 5 to 110VDC 12 to 240VAC 3 NO 60LRA/14FLA, 240VAC (AC coil only) 100x10 Max. coil power 1.7W 4.0VA 3 NO 3A, 240VAC, pilot duty 100x10 Max. coil temperature 155C 3 NO 20A, 28VDC, resistive 100x10 Coil insulation system according UL Class F 3 NO TV10, 120VAC 100x10 Coil versions, DC coil 3 NC 3A, 277VAC 100x10 Coil Rated Operate Release Coil Rated coil 3 NC 2A, 480VAC 100x10 code voltage voltage voltage resistance power 3 NC 1A, 600VAC 100x10 VDC VDC VDC 10% W AgSnOInO 6 6 4.5 0.6 22 1.7 3 NO 30A, 120/277VAC, resistive (DC coil only) 200x10 9 9 6.75 0.9 48 1.7 3 NO 30A, 120/277VAC, resistive (AC coil only) 100x10 12 12 9 1.2 86 1.7 3 NO 20A, 480VAC, resistive 100x10 18 18 13.5 1.8 197 1.7 3 NO 1.5HP, 120VAC, 2 pole making/breaking (Fig.1) 100x10 24 24 18 2.4 350 1.7 3 NO 3HP, 240VAC, 3 phase (DC coil only) 100x10 48 48 36 4.8 1390 1.7 3 NO 3HP, 480VAC, 3 phase (DC coil only) 100x10 110 110 82.5 11 7255 1.7 3 NO 2HP, 600VAC, 3 phase (DC coil only) 100x10 Coil versions, AC coil VDE Coil Rated Frequency Operate Release Coil Rated coil AgCdO, flange mount relays code voltage voltage voltage resistance power 3 VAC Hz VAC, 60Hz VAC, 60Hz 10% VA NO 20A, 400VAC 100x10 3 NC 3A, 400VAC 30x10 12 12 60 9.6 1.2 9.1 4 3 CO 20A NO / 3A NC, 400VAC 30x10 24 24 60 19.2 2.4 36.6 4 AgCdO, PC mount relays 120 110/120 50/60 96 12 950 4 3 NO 30A, 400VAC 100x10 240 220/240 50/60 192 24 3800 4 3 NC 3A, 400VAC 30x10 277 250/277 50/60 222 28 5485 4 3 All figures are given for coil without preenergization, at ambient temperature +23C. CO 30A NO / 3A NC, 400VAC 30x10 1 11-2012, Rev. 1112 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section, www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are 2012 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change. a TE Connectivity Ltd. company. AC Coil 30 A AC Coil 0 A DC Coil 30 Amp Contact Load DC Coil 0 Amp Contact Load General Purpose High Power PCB Relays PPottotter & Brumfielder & Brumfield T92 Series Two-pole 30A PCB or Panel Mount Relay (Continued) Coil Data (continued) Other Data Ambient temperature vs. coil voltage Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content Assumptions: refer to the Product Compliance Support Center at 1. Thermal resistance = 35C per Watt (DC only.) www.te.com/customersupport/rohssupportcenter 2. Still air. Ambient temperature 3. Nominal coil resistance. DC coil -55C to 85C 4. Max. mean coil temperature = 155C (change of resistance method). AC coil -55C to 65C 5. Coil temperature rise due to load = 6.3C 30 amps. Category of environmental protection 6. Curves are based on 1.7W at 25C (DC only.). IEC 61810 RTI - dust protected, RTII - flux proof, RTIII - wash tight 120 Vibration resistance (functional) 1.65mm max excursions, 10-55 Hz Shock resistance (functional) 10g for 11msec 100 Shock resistance (destructive) 100g 80 Terminal type PCB-tht or quick connect Weight 86g 60 Resistance to soldering heat THT IEC 60068-2-20 250C 40 Packaging/unit tray/30 pcs., box/120 pcs. 20 0 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 Applied Coil Voltage (% of Rated Nominal) Insulation Data Initial dielectric strength between open contacts 1500V rms between contact and coil 4000V rms between adjacent contact 2000V rms Initial surge withstand voltage between contact and coil 6kV Initial insulation resistance 9 between insulated elements 1x10 Clearance/creepage between contact and coil 8mm clearance/9.5mm creepage Dimensions T92 Mounting and termination code 1 T92 Mounting and termination code 2, 3 and 4 2.06 MAX. 1.36 MAX. 2.700 MAX. 1.36 MAX. (52.32) (34.54) (68.58) (34.54) 1.04 MAX. 1.21 MAX. 1.495 MAX. (26.42) (30.73) .156 (37.97) (3.96) .250 TYP. (6.35) 1.618 .020 (41.10 .51) .047 TYP585 .005 2.05 MAX. (1.19) (14.86 .13) (52.07) .032 TYP309 .005 (0.81) 2.345 .005 (7.85 .13) (59.56 .13) 1.618 TYP. (41.10 .51) .585 .005 (14.86 .13) .309 .005 1.000 .010 .630 .005 (7.85 .13) (25.40 .25) (16.00 .13) .090 RAD. (2.29) FOR 8 SCREW .630 TYP. (16.00) 2 11-2012, Rev. 1112 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section, www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are 2012 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change. a TE Connectivity Ltd. company.