CTC-0073
SPECIFICATION CONTROL DRAWING
Date Revision
TITLE
TWO CONDUCTOR THERMOCOUPLE EXTENSION CABLE, SHIELDED, JACKETED 3-19-13 B
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
COMPONENT WIRES -
1 of WTC-0004 (COPPER)
JACKET - RADIATION-CROSSLINKED,
SHIELD - TIN-COATED COPPER
1 of 55A8129 (CONSTANTAN)
MODIFIED ETFE
CABLE CONSTRUCTION DETAILS
JACKET THICKNESS OUTSIDE DIAMETER
CONDUCTOR SHIELD NOMINAL
PART NUMBER
(inches) (inches)
SIZE SIZE WEIGHT
1/
(AWG) (AWG) (lbs/1000 ft.)
MINIMUM NOMINAL NOMINAL MAXIMUM
CTC-0073-22-* 22 38 .006 .008 .133 .140 13.5
CTC-0073-20-* 20 38 .006 .008 .151 .159 17.8
CTC-0073-18-* 18 38 .006 .008 .171 .180 23.4
CTC-0073-16-* 16 38 .006 .008 .185 .194 28.2
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150C PART NUMBER:
Maximum continuous conductor temperature The * in the part numbers above shall be replaced by color code
ACCELERATED AGING: 300 3C for 7 hours designators with a slash separating the component wire colors and a
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz dash separating the component wire colors from the jacket color. The
FLAMMABILITY (Procedure 1): 3 seconds (maximum); color of copper shall be shown first.
3 in. (maximum); no flaming of facial tissue
JACKET ELONGATION AND TENSILE STRENGTH: 1/ Example: AWG 22,
Elongation, 50% (minimum) Per MIL-STD-687: Red (Copper), yellow (Constantan); white jacket:
Tensile Strength, 5000 lbf/in (minimum) CTC-0073-22-2/4-9
JACKET FLAWS: Per ANSI MC96.1: Blue (Copper), red (Constantan); blue jacket:
Spark Test, 1000 volts (rms) CTC-0073-22-6/2-6
Impulse Dielectric Test, 6.0 kV (peak) Per British Standard Code BS:
LOW TEMPERATURE-COLD BEND: -65 2C for 4 hours White (Copper), blue (Constantan); blue jacket:
SHIELD COVERAGE: 85% (minimum) CTC-0073-22-9/6-6
VOLTAGE WITHSTAND (Post Environmental):
1000 volts (rms), 60 Hz, 1 minute
The combination of the above thermoelements is referred to as Type TX per ANSI MC96.1.
EMF shall be 4.23 mV (minimum), 4.32 mV (maximum), at 100C with reference junction corrected to 0C per ANSI MC96.1,
and shall be performed on every length of finished cable.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. Raychem Wire & Cable
501 Oakside Avenue
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
Redwood City, CA 94063-3800
Page 1 of 1
Phone: 1-800-227-8816
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
Fax: 1-650-361-6297
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
2013 Tyco Electronics Corporation. All rights reserved.X-ON Electronics
Largest Supplier of Electrical and Electronic Components
Click to view similar products for Multi-Conductor Cables category:
Click to view products by TE Connectivity manufacturer:
Other Similar products are found below :
89504-002-1000 89705-008-500 6000FE-877-1000 CS2885-000 M27500-20SP2S23 6309UE-877-1000 M3905-BK005 6502FE 8771000
CW9530-000 CX6543-000 CXA-0066-20-4-9CS2973 CXA-0078-16-1-9CS2405 CXA-0078-22-4-9CS2405 CXA-0078-24-4-9CS2405
CXA-0140-16-6/9-9CS2405 CY0660-000 720451-000 752687-000 768146-000 773159-000 83318E-009-500 8348-060-500 83559-002-
1000 83653-002-5000 8404-060-500 8469 060100 858171-000 8628-060-500 868361-001 8730-060-1000 8737-060-U1000 8747-060-100
8747-060-1000 8769-060-1000 8775-060-500 8780-060-1000 8782-001-U1000 9159-060-500 9318-060-1000 939870-000 9423 060U500
9444 060U1000 9497 0001000 9520-060-1000 9524-060-1000 9546-060-500 9572-002-U500 9774-060-1000 A43962-000 1232A1-008-
1000