SPECIFICATION CONTROL DRAWING
Product Revision Component Dimensions GA Cable Dimensions
Product L A B C Wire Gauge D E F G0.5 M0.5
Name max min min min (AWG) min (G0.02) (M0.02)
B-040-20-N D 20 1.70 1.50
B-040-22-N D 22 (0.065) (0.060)
B-040-24-N D 30.0 4.40 2.80 1.60 24 to to 0.30 16.0 6.0
B-040-26-N D (1.180) (0.175) (0.110) (0.060) 26 4.40 2.80 (0.012) (0.630) (0.235)
B-040-28-N D 28 (0.175) (0.110)
B-040-30-N D 30
MATERIALS
1. & 5. INSULATION SLEEVE: Heat-shrinkable, radiation cross-linked modified polyvinylidene fluoride. Transparent blue.
2. & 4. SOLDER PREFORMS WITH FLUX:
SOLDER: TYPE Sn63 per ANSI J-STD-006.
FLUX: TYPE ROL1 per ANSI J-STD-004.
3. & 6. MELTABLE RINGS: Thermally stabilized thermoplastic.
7. CONDUCTOR LEAD: MIL-W-22759/32-GA-9, AWG GA (see table). ETFE insulated, stranded tin plated copper.
Color: white.
8. GROUND LEAD: MIL-W-22759/32-GA-6, AWG GA (see table). ETFE insulated, stranded tin plated copper.
Color: blue.
APPLICATION
1. The parts covered by this SCD are for use in terminating the primary conductor and the braided shield of a coaxial cable
having tin or silver plated conductor and shield, rated for at least 125 C and meeting the dimensional requirements listed.
2. Parts will meet the requirements of Raychem Specification RT-1404 when installed per Raychem RPIP-500-03.
3. Temperature range: -55C to +150C.
For best results, prepare
the cable as shown:
TITLE:
TE Connectivity
Raychem
305 Constitution Drive
COAXIAL SOLDERSLEEVE DEVICE
Products
Menlo Park, CA 94025, USA
WITH PRE-INSTALLED STRANDED WIRES
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS.
DOCUMENT NO.: B-040-GA-N
INCHES DIMENSIONS ARE BETWEEN BRACKETS.
TOLERANCES: ANGLES: N/A TE Connectivity reserves the right to amend this DATE: DOC ISSUE:
0.00 N/A drawing at any time. Users should evaluate the
15-Apr-11 3
0.0 N/A ROUGHNESS IN suitability of the product for their application.
0 N/A MICRON
DRAWN BY: REPLACES: DCR NUMBER: PROD. REV. SCALE: SIZE: SHEET:
M. FORONDA D000433 D000581 SEE TABLE None A 1 of 1
Print Date: 9-May-11 If this document is printed it becomes uncontrolled. Check for the latest revision.