SPECIFICATION CONTROL DRAWING C5E-24B114-Y18 Date: 1/8/2020 Issue: E CAT5e CABLE, AWG 24 Page 1 of 2 THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION WCD 2015. CONSTRUCTION DETAILS TABLE II Conductor Pair Component Dimensions Insulation inches (nom) AWG 24 7/32, tin-coated copper Conductor: .024 Pair 1 Insulation: Foamed Polyethylene .047 4 Cable Assembly Inner Shield 3 Core: 4 Pairs .213 2 Inner Shield Aluminum/PET Wrap, .0025 inch thick, .223 Outer shield 25% min. overlap. Outer Shield: AWG 34, tin-coated copper .249 Jacket Optimized to meet ZT requirement. Jacket: Zerohal, .040 inch thickness .328 .030 TABLE I - Insulation Color Coding Cable Weight: 60.52 lbs/kft Pair Wire 1 Wire 2 Designate outer jacket color with a dash number appended to the part number. Example: Black jacket C5E-24B114-Y18-0 1 9 (white) 6L (light blue) 2 9 (white) 3L (light orange) Color code designators shall be in accordance with MIL-STD-681. An L after the number indicates a light color. 3 9 (white) 5L (light green) 4 9 (white) 1L (light brown) ELECTRICAL CHARACTERISTICS TABLE III Frequency Insertion Loss Return Loss NEXT ACRF PS NEXT PSACRF Propagation Delay MHz dB/100m dB/100m dB/100m dB/100m dB/100m dB/100m ns/100m (max) (min) (min) (min) (min) (min) (max) 1 2.4 20.0 65.3 63.8 62.3 60.8 570 4 4.9 23.0 56.3 51.8 53.3 48.8 552 8 6.9 24.5 51.8 45.7 48.8 42.7 547 10 7.8 25.0 50.3 43.8 47.3 40.8 545 16 9.8 25.0 47.3 39.7 44.2 36.7 543 20 11.1 25.0 45.8 37.8 42.8 34.8 542 25 12.5 24.2 44.3 35.8 41.3 32.8 541 31.25 14.0 23.3 42.9 33.9 39.9 30.9 540 62.5 20.4 20.7 38.4 27.9 35.4 24.9 539 100 26.4 19.0 35.3 23.8 32.3 20.8 538 Note: Values in Table III for RL and NEXT are for reference only. Actual values shall be determined utilizing the formulas in ANSI/TIA-568.2 (issue in e ect). Electrical Testing: In accordance with ANSI/TIA-568.2 (issue in e ect). Capacitance: Mutual Capacitance: 5.6 nF/100 m (nom) at 1 kHz. Pair to ground capacitance unbalance: 330 pF/100 m (max) at 1 kHz. Impedance: 100 15 ohms at 1 to 100 MHz. (for reference only). Conductor DC Resistance: 26.2 ohms/1000 ft (nominal) 20C. Delay Skew: 45 ns/100 meter (maximum) at 1 to 100 MHz. Surface Transfer Impedance: 700 milliohms/m (max) at .1 to 100 MHz,60dB (min) EMP response per MIL-DTL-24643 on a .33 meter test sample. Velocity of Propagation: 74% (nominal) TE Connectivity Corporation Other codes and su xes may be added to the part number, as necessary, to capture any additional requirements imposed Raychem Wire & Cable by the purchase order. Users should evaluate the suitability of this product for their application. TE Connectivity 501 Oakside Avenue Corporation also reserves the right to make changes in materials or processing, which do not a ect compliance with any Redwood City, California 94063-3800 speci cation, without noti cation to Buyer. 1-800-522-6752 This speci cation sheet takes precedence over documents referenced herein. Referenced documents shall be of the issue in e ect on date of invitation for bid. Raychem, Rayfoam, Zerohal, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. 2014-2020 TE Connectivity Corporation. All rights reserved.SPECIFICATION CONTROL DRAWING C5E-24B114-Y18 Date: 1/8/2020 Issue: E Page 2 of 2 ADDITIONAL REQUIREMENTS & RATINGS Temperature Rating: -40C to 105C Shield: Shield AWG is nominal to allow for changes to meet the surface transfer impedance. Speci cation: Spec 1200 (Electricals) Cable will be supplied in 50 ft minimum lengths unless otherwise speci ed. TE Connectivity Corporation Raychem Wire & Cable 501 Oakside Avenue Redwood City, California 94063-3800 1-800-522-6752