Catalog 1308242 Issued 3-03 P&B CS series Solid State Hybrid Voltage Sensor Close differential Choice of two types Fixed pick-up and knob adjustable drop-out Knob adjustable pick-up and drop-out Internal 2 Form C (DPDT) output relay File E22575 Fixed Pick-up and Adjustable Pick-up File LR15734 Adjustable Drop-out and Drop-out Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Engineering Data Sensing Modes Power Requirement: Typically less than 3VA or 3W. The CS can be used as an over or undervoltage sensor, depending upon Duty Cycle: Continuous. whether the load is connected to the normally closed (NC) or normally open Repeatability: 1%, max. (NO) contacts of the sensors output relay. Response Time: 10-25 ms, typ. Internal Relay Contact Arrangement: 2 Form C (DPDT). Overvoltage sensor The NC contacts are used. The relay remains de- Internal Relay Contact Rating: 10A 28VDC , res., or 120VAC, 80% p.f. energized until an overvoltage is sensed. Reverse Polarity Protection: On DC types. Temperature Range: -10C to +55C. Undervoltage sensor The NO contacts are used. The relay remains en- Temperature Coefficient: 0.2%/C, max. ergized until the voltage decreases to the preset level, where the sensor Enclosure: Plastic dust cover. de-energizes the relay. Mounting: 8-pin octal style plug. Fits either 27E122 or 27E891 (snap-on) screw terminal sockets. Weight: 8 oz. (227g) approximately. Adjustable Voltage Sensor Operation Ordering Information Distributors are more likely to stock boldface items. Note 1 As voltage increases, the RELAY Fixed Pick-Up and Adjustable Drop-Out relay will pick-up at its selected ENERGIZED point and remain energized while Part Number Pick-Up Drop-Out Range Maximum voltage is maintained at that level or (Volts) (Volts) Voltage higher. CSJ-38-71010 105 90-103 140VAC (50/60 Hz.) CSL-38-31010 22 16-21 32VDC Note 2 As voltage decreases, af- HYSTERISIS ter pick-up, the relay will drop-out at Adjustable Pick-Up and Adjustable Drop-Out 2 VOLTS its selected point. Part Number Pick-Up Range Drop-Out Range* Maximum (Volts) (Volts) Voltage Note 3 Minimum hysterisis, the RELAY CSJ-38-70010 92-140 90-138 150VAC (50/60 Hz.) voltage differential between pick-up DE-ENERGIZED CSL-38-30010 20-30 18-28 32VDC and drop-out, is typically 2% of CSL-38-40010 40-58 38-56 60VDC pick-up. CSL-38-60010 92-140 90-138 150VDC * Actual maximum drop-out voltage is the selected pick-up voltage less the hysterisis voltage. NOTE 1 NOTE 2 Outline Dimensions Wiring Diagrams Bottom Views (pins numbered clockwise from keyway) 1.781 MAX600 MAX. (42.24) (15.24) .875 2.937 MAX560 (22.23) (76.60) (14.22) - 1.187 + AC DC (30.15) INPUT INPUT Dimensions are shown for Dimensions are in inches over Specifications and availability www.tycoelectronics.com reference purposes only. (millimeters) unless otherwise subject to change. Technical support: 1302 specified. Refer to inside back cover. VOLTAGE 2.406 MAX. (61.11)X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Time Delay & Timing Relays category: Click to view products by TE Connectivity manufacturer: Other Similar products are found below : 5NO30 614-11B-0A2 614-11B-OA3 614-11B-OA4 614-11B-OA6 614-11B-OA8 614-11C-OA1 614-11C-OA2 614-11C-OA5 614-11Q- OA3 614-11Q-OA6 614-11T-OA3 614-11T-OA6 614-11T-OA7 614-12B-4A1 614-12C-400 614-12Q-400 614-12T-600 614-22T-4A1 614-43B-400 614-43C-100 614-43F-200 614-43Q-0A2 614-43Q-100 614-43Q-600 614-43T-0A9 614-43T-600 614-43U-400 614-43U-4A1 614-43U-6A2 615-21T-200 655-11T-100 655-11U-500 655-12T-300 655-22T-400 655-22T-600 CUA-41-30001 CUA-41-30030 CUA-41- 70180 CUA-41-71038 CUA-42-30005 CUA-42-30010 CUA-42-30120 CUA-42-70120 CUA-99-72502 CUC-41-30030 CUF-42-30010 CUH-41-31006 7012AFX 7012GD