SPECIFICATION CONTROL DRAWING TITLE: Tyco Electronics Corporation Raychem Hi-Spec Flexible Bus Cable Joint 300 Constitution Drive, Raychem Menlo Park, CA. 94025, U.S.A. MIL-STD-1553B Lightweight System DOCUMENT NO.: Unless otherwise specified dimensions are in millimeters. Inches dimensions are shown in brackets D-150-9133 TOLERANCES: ANGLES: N/A Tyco Electronics reserves the right to 0.00 N/A amend this drawing at any time. Users DOC. ISSUE: DATE: 0.0 N/A ROUGHNESS IN should evaluate the suitability of the 1 27-Sept-00 0 N/A MICRON product for their application. DRAWN BY: CAGE CODE: REPLACES: DCR NUMBER: PROD. REV.: SCALE: SIZE: SHEET: M. FORONDA 06090 N/A D000423 F None A 1 of 2 If this document is printed it becomes uncontrolled. Check for the latest revision. MATERIALS 1. SEALING SLEEVE: High temperature fluid stabilized cross-linked elastomer to Specification RK-6008. Color: black. 2. MELTABLE RINGS: Modified stabilized elastomer-fluoropolymer thermoplastic. 3. BRAID: Solder impregnated, flux coated, tin plated copper wire braid. SOLDER: TYPE Sn96 per ANSI J-STD-006. FLUX: TYPE ROM1 per ANSI-J-STD-004. 4. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified polyvinylidene fluoride. 5. SOLDER PREFORM: SOLDER: TYPE Sn96 per ANSI J-STD-006. 6. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified polyvinylidene fluoride. 7. CRIMP: Copper Alloy 102 per ASTM B75. Tin plated per MIL-T-10727 Type T. Red stripe code. APPLICATION 1. This flexible cable joint is designed to facilitate the assembly or maintenance of pre-cabled digital harness components for MIL-STD-1553B networks. It should be used where continuous flexing is not a functional requirement. 2. Cables to be joined, Raychem 10612, 10613, 10614. 3. Minimum bend radius Static: 80mm. Dynamic: not recommended. 4. Temperature range: -65 C to +150 C. Brief excursions to 200 C permissible without degradation. 5. Designed to meet performance requirements of Raychem Specification HPDS-0519. 6. For installation procedure and tooling, see RPIP-600-12. DRAWN BY: CAGE CODE: REPLACES: DCR NUMBER: PROD. REV.: SCALE: SIZE: SHEET: M. FORONDA 06090 N/A D000423 F None A 2 of 2 If this document is printed it becomes uncontrolled. Check for the latest revision.