SCD ATF+0311 SPECIFICATION CONTROL DRAWING Date Revision Title AUTOMATIC TRANSMISSION CABLE, 1-29-15 H RADIATION-CROSSLINKED, MODIFIED FLUOROPOLYMER-INSULATED, 600 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 63. CONDUCTOR - TIN-COATED COPPER INSULATION - RADIATION-CROSSLINKED, MODIFIED FLUOROPOLYMER TABLE I. CONSTRUCTION DETAILS FINISHED CABLE CONDUCTOR DIAMETER CONDUCTOR DIAMETER MAXIMUM (inch) (mm) WIRE NOMINAL PART NUMBER STRANDING (inch) (mm) RESISTANCE SIZE WEIGHT 1/ (number x AT 20C (AWG) LOWER UPPER LOWER UPPER (lbs/1000 ft.) TARGET AWG) (ohms/1000 ft.) SPEC SPEC SPEC SPEC (kg/km) VALUE (ohms/km) LIMIT LIMIT LIMIT LIMIT ATFC0311-22-* 22 19 x 34 .029 (.737) .031 (.787) 16.2 (53.1) .044 (1.12) .046 (1.17) .048 (1.22) 3.0 (4.46) ATFC0311-20-* 20 19 x 32 .037 (.940) .039 (.991) 9.88 (32.4) .052 (1.32) .054 (1.37) .056 (1.42) 4.4 (6.55) ATFC0311-18-* 18 19 x 30 .046 (1.17) .049 (1.24) 6.23 (20.4) .061 (1.55) .063 (1.60) .065 (1.65) 6.6 (9.82) ATFC0311-16-* 16 19 x 29 .052 (1.32) .055 (1.40) 4.81 (15.8) .066 (1.68) .069 (1.75) .072 (1.83) 8.3 (12.4) ATFC0311-14-* 14 19 x 27 .065 (1.65) .069 (1.75) 3.06 (10.0) .083 (2.11) .086 (2.18) .089 (2.26) 12.9 (19.2) ATFD0311-16-* 16 37 x 32 .051 (1.30) .056 (1.42) 4.98 (16.3) .067 (1.70) .070 (1.78) .073 (1.85) 8.5 (12.6) ATFD0311-14-* 14 37 x 30 .067 (1.70) .072 (1.83) 3.11 (10.2) .089 (2.26) .093 (2.36) .097 (2.46) 15.5 (23.1) Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS SHALL BE IN ACCORDANCE WITH SAE J1128. COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH SPEC 63. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Dexron, Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Raychem Wire & Cable 501 Oakside Avenue DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. Redwood City, CA 94063-3800 Page 1 of 2 Phone: 1-800-227-8816 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 2010-2015 Tyco Electronics Corporation. All rights reserved. Page Revision SCD SPECIFICATION CONTROL DRAWING 2 of 2 H ATF+0311 TABLE II. PERFORMANCE DETAILS HEAT RESISTANCE - BEND TESTING DYNAMIC CUT-THROUGH (lb) (kg) (minimum) PART NUMBER MANDREL DIAMETER WEIGHT 1/ AFTER (inch) (mm) ( 3%) (lb) (kg) ( 3%) INITIAL IMMERSION ATFC0311-22-* .750 (19.1) .375 (.170) TBD TBD ATFC0311-20-* .750 (19.1) .375 (.170) 20 (9.07) 20 (9.07) ATFC0311-18-* .750 (19.1) .375 (.170) TBD TBD ATFC0311-16-* .750 (19.1) .375 (.170) TBD TBD ATFC0311-14-* .750 (19.1) .375 (.170) TBD TBD ATFD0311-16-* 1.00 (25.4) .500 (.227) TBD TBD ATFD0311-14-* 1.00 (25.4) .500 (.227) TBD TBD CABLE RATINGS AND ADDITIONAL REQUIREMENTS VOLTAGE RATING: 600 volts (dc) at sea level THERMAL STABILITY: Short Term, 200 3C for 168 hours CONCENTRICITY: 70% (minimum) Elongation Retention, 80% (minimum) CROSSLINK PROOF TEST: Per QC/3/117 Tensile Strength Retention, 80% (minimum) FLAMMABILITY: 70 seconds (maximum) afterburn TRANSMISSION FLUID RESISTANCE: Dexron VI, 150 2C for 720 hours HEAT RESISTANCE: 150 2C for 1 hour Diameter Swell, 5% (maximum) no cracking, no dielectric breakdown Mandrel Wrap, 1x diameter mandrel, no dielectric breakdown INSULATION ELONGATION AND TENSILE STRENGTH: Dynamic Cut-Through, see Table II (Pulled at 2 inches (51 mm) per minute) VOLTAGE WITHSTAND (Post Environmental): Elongation, 150% (minimum) 1000 volts (rms), 60 Hz, 1 minute 2 2 Tensile Strength, 3000 lbf/in (20.7 N/mm ) (minimum) INSULATION FLAWS: 1/ PART NUMBER: Impulse Dielectric, The in the part number in the upper right hand corner of pages 1 and 2 ATFC0311, 14 AWG and smaller, 5.0 kV (peak) shall be replaced with a letter designator to define conductor stranding ATFD0311-16, 5.0 kV (peak) (see part numbers in table). ATFD0311-14, 6.0 kV (peak) C = 19 Strands D = 37 Strands INSULATION RESISTANCE: 1000 kohms for 1000 ft. (305 kohms for 1 km) (minimum) The in the part numbers in Tables I and II shall be replaced by a color LOW TEMPERATURE-COLD BEND: -55 3C for 4 hours code designator. SHRINKAGE: 0.050 inch (1.27 mm) (maximum) Example: AWG 20, 19 strands, dark blue: ATFC0311-20-6D STRIP FORCE: 4.5 lbs (2.04 kg) (minimum) 1/ See footer section on page 1