Specification Control EPD-MPP-10150
R
Drawing 3 conductor cable
Issue C - 12/18/2013
Identification, colors & marks Cross section
A
9
A A
6 3
Components
ID Quantity Part number Description
A 3 55PC0113-22 Primary Wire
Cable
Outer Description Thickness OD
Inches mm Inches mm
Core 0.089 2.27
Shield Round tinned copper 38 awg regular 0.009 0.22 0.106 2.70
Jacket Thermorad FL blue 0.005 0.13 0.116 2.96
Shield Round tinned copper 38 awg optimized 0.009 0.22 0.133 3.39
Jacket Thermorad FL white 0.010 0.25 0.153 3.90
Cable OD tolerance + 0.008 + 0.20
Raychem WCD 3313
Specification
25.23 lb/kft 37.62 Kg/Km
Weight
Page 1 of 2
This specification sheet takes precedence over documents referenced herein.
Referenced documents shall be of the issue in effect on date of invitation to bid.
Proposed specification control drawings may be altered prior to final issue.
RCD Version 1.2 Level 1 Ser #5 RWC 8/7/95Specification Control EPD-MPP-10150
R
Drawing 3 conductor cable
Issue C - 12/18/2013
Continued
Physical properties
Component Sequence The placing of the components in the cross sectional view of the cable is for
reference only and is not a requirement
Shield Coverage First Shield: 85% coverage minimum
Outer Shield: 95% coverage nominal
Electrical properties
Optimized shield Maximum surface transfer impedance of 100 milli ohms / meter at 30 Mhz.
Notes
Colors Color code designators shall be in accordance with MIL-STD-681.
Dimensions Dimensions are in inches, and unless otherwise designated, are nominal.
Export License Note The information contained on this drawing may be subject to International Traffic in
Arms Regulations (ITAR) or Export Administration Regulations (EAR) controls and
may not be disclosed to any foreign person or firm, including foreign persons
employed by or associated with your firm, without first complying with all
requirements for obtaining an export license if applicable.
Identification, Colors & Marks Primary wire colors: White, Blue and Orange.
Inner jacket color: Blue
Outer jacket color: White with marking as shown below.
Minimum length Cable will be supplied in 50 ft. minimum lengths unless otherwise specified.
Part Number Note Other codes and suffixes may be added to the Part Number as necessary, to
capture any additional requirements imposed by the purchase order
Specification Information This drawing is the property of Tyco Electronics Corporation and may not be used
for any purpose other than for that which it is supplied without the express written
authority of Tyco Electronics Corporation.
Raychem, Thermorad , TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks.
Trademarks
Jacket identification Mark: RAYCHEM - EPD-MPP-10150 - 06090 - Year of Manufacture.
Page 2 of 2
This specification sheet takes precedence over documents referenced herein.
Referenced documents shall be of the issue in effect on date of invitation to bid.
Proposed specification control drawings may be altered prior to final issue.
RCD Version 1.2 Level 1 Ser #5 RWC 8/7/95