Rev. B EV202 SERIES DPST-NO CONTACTOR (2 form X) With option of 2 SPDT (form C) Auxiliary Switch Outputs. 2 Pole Single-Throw Contactor 400Vdc/ 350A per Pole 12 or 24 VDC Coil Optional 2-SPDT auxiliary switch outputs: o 30Vdc/ 2A max switching, or o 6V/ 5mA min signal Hermetically Sealed Integrated Coil Economizer with Coil Suppression EMC Compliant No radiated coil emission -55C to + 85C Operating Range Bidirectional Switching Main contacts not polarity sensitive EV202MSAND Shown (2 Aux Switches) Mount in any orientation not position sensitive RoHS Compliant TITLE EV202 CONTACTOR SERIES 550 Linden Ave. Carpinteria, CA US 93013 SD- EV202 Internet: www.te.com CAGE CODE SCALE SHEET 18741 NONE CD CUSTOMER DRAWING 1 of 6 Rev. 3310 Form 13.10 Rev. B General Specifications Physical Data Units Contact Arrangement: Power Contacts - DPST-NO (2 form X) Auxiliary Switches SPDT (form C) Number of Switches per Contactor Type: EV202AS None EV202MS Two Dimensions - See drawing Weight, Nominal (not including hardware) Kg 0.77 Environmental Data Gpeak 20 Shock, 11ms sine (operating) Hz 10-2000 Sine Vibration, 10 G peak Random Vibration, 14 Grms Hz 15 100 300 900 2000 .01 .01 .2 .2 .01 2 G /Hz Operating Temperature Range -55 to +85 C Electrical Data Voltage Rating: Main Contacts (max) Vdc 600 Auxiliary contacts Vdc 30 Current Rating: Continuous: Main Contacts (1) A/Pole 350 Auxiliary contacts A 3 Contact Resistance: Main Contacts (2) m 100 max 1 amp 0.3 max 200A after 3 minutes Auxiliary Contacts m 200 max Hot Switching performance 400Vdc (3) cycles 100A make/ break 10,000 250A make/ break 2,500 700A break only 10 Hot Switching performance 270Vdc (4) cycles 100A make/ break 40,000 250A make/ break 7,500 2000A break only 370Vdc (5) 2 Maximum Closing Into (Make) Current A 700 Mechanical Life cycles 100,000 Dielectric Withstand Voltage over life: Terminal to Terminal/ Terminals to Coil 1mA max 2,200Vrms Insulation Resistance over life: Terminal to Terminal/ Terminals to Coil 50M min 500Vdc (1) Using 4/0 conductor. Current rating is affected by attached conductor size and design. Keep terminals below 150C max continuous, 175C for 2 hours max, and 200C for 1 minute max. For mounting large conductors, request terminal adapter PN 3-1618396-7. (2) Operational contact resistance is measured by millivolt drop across contacts a >100A current. Initial contact resistance may be higher than 0.3m, but will drop below within 30 minutes maximum. (3) Voltage applied to each contact set separately. (4) Voltage applied across both contact sets in series (5) Dielectric Withstand Voltage may be degraded following 2000A interrupts at 370Vdc. CUSTOMER DRAWING SD- EV202 THIRD ANGLE PROJECTION THIS DRAWING CAGE CODE SCALE SHEET PREPARED IN ACCORDANCE WITH 18741 NONE 2 of 6 ANSI/ASME Y14.5M-1982 Rev. 3310 Form 13.10