MS5805-02BA01 Miniature Altimeter Module High resolution module, 20 cm Fast conversion down to 0.5 ms Low power, 0.6 A (standby < 0.15 A at 25C) Integrated digital pressure sensor (24 bit ADC) Supply voltage 1.8 to 3.6 V Operating range: 300 to 1200 mbar, -40 to +85 C Extended pressure range: 10 to 2000 mbar 2 I C interface No external components (Internal oscillator) Excellent long term stability Sealing designed for 2.5 x 1mm O-ring DESCRIPTION 2 The MS5805-02BA is a new generation of high-resolution altimeter sensors from MEAS Switzerland with I C bus interface. It is optimized for altimeters and variometers with an altitude resolution of 20 cm. The sensor module includes a high-linearity pressure sensor and an ultra low power 24 bit ADC with internal factory- calibrated coefficients. It provides a precise digital 24 Bit pressure and temperature value and different operation modes that allow the user to optimize for conversion speed and current consumption. A high-resolution temperature output allows the implementation of an altimeter/thermometer function without any additional sensor. The MS5805-02BA can be interfaced to virtually any microcontroller. The communication protocol is simple, without the need of programming internal registers in the device. This new sensor module generation is based on leading MEMS technology and latest benefits from MEAS Switzerland proven experience and know- how in high volume manufacturing of altimeter modules, which have been widely used for over a decade. The sensing principle employed leads to very low hysteresis and high stability of both pressure and temperature signal. FEATURES FIELD OF APPLICATION TECHNICAL DATA Sensor Performances (V = 3 V) Mobile altimeter / barometer systems DD Pressure Min Typ Max Unit Bike computers 10 2000 Adventure or multi-mode watches Range mbar Variometers ADC 24 bit 0.35 / 0.19 / 0.11 / Dataloggers Resolution (1) mbar 0.06 / 0.03 / 0.02 Accuracy 25C, -2 +2 mbar FUNCTIONAL BLOCK DIAGRAM 750 to 1100 mbar Accuracy -20C to + 85C, -4 +4 mbar VDD 300 to 1200 mbar (2) 0.5 / 1.1 / 2.1 / 4.1 / Response time ms 8.22 / 16.44 2 +IN I C Bus SENSOR SDA Interface Long term stability 1 mbar/yr dig. ADC -IN Filter SCL Temperature Min Typ Max Unit Sensor Memory Range -40 +85 C (PROM) Interface IC 112 bits SGND Resolution <0.01 C GND Accuracy -1 +1 C Notes: (1) Oversampling Ratio: 256 / 512 / 1024 / 2048 / 4096/ 8192 (2) With autozero at one pressure point MS580502BA01 003 ww.meas-spec.com July 24, 2014 000058052459 ECN2317 1/17 MS5805-02BA01 Miniature Altimeter Module PERFORMANCE SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS Parameter Symbol Conditions Min. Typ. Max Unit Supply voltage V -0.3 +3.6 V DD Storage temperature T -20 +85 C S Overpressure P 5 bar max Maximum Soldering T 40 sec max 250 C max Temperature Human Body ESD rating -2 +2 kV Model JEDEC standard Latch up -100 +100 mA No 78 ELECTRICAL CHARACTERISTICS Parameter Symbol Conditions Min. Typ. Max Unit Operating Supply voltage V 1.8 3.0 3.6 V DD Operating Temperature T -40 +25 +85 C OSR 8192 20.09 4096 10.05 Supply current 2048 5.02 I A DD (1 sample per sec.) 1024 2.51 512 1.26 256 0.63 Peak supply current during conversion 1.25 mA Standby supply current at 25C (V = 3.0 V) 0.01 0.1 A DD VDD Capacitor From VDD to GND 100 470 nF ANALOG DIGITAL CONVERTER (ADC) Parameter Symbol Conditions Min. Typ. Max Unit Output Word 24 bit OSR 8192 16.44 4096 8.22 2048 4.13 Conversion time t ms c 1024 2.08 512 1.06 256 0.54 MS580502BA01 003 ww.meas-spec.com July 24, 2014 000058052459 ECN2317 2/17