Catalog 1308242 Issued 3-03 (PDF Rev. 5-05) P&B P25 series Definite Purpose Magnetic Contactor 25 Ampere Full Load 30 Ampere Resistive AC & DC Coils File E22575 File LR15734 P25 with DC coil P25 with AC coil Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Coil Data Features AC and DC coils. Nominal Resistance Must Maximum Nominal Coil For controlling motors, power supplies, heating elements and lighting. VDC (Ohms 10% Operate* Operating Current (ma) Dust cover available. 25C) Volts Volts Nominal Voltage Auxiliary switch available. 12 34 9 15 353 24 133 18 30 180 AC Voltage Nominal Must Operate Contact Data 25C Rating 60 Hz. 50 Hz. 60 Hz. 50 Hz. Arrangements: Up to 3 Form X (3PST-NO-DM). 24 24 24 20.4 20.4 Ratings: See contact rating table. 120 120 110 102 94 Material: Silver-cadmium oxide. 240 208/240 208/220 177 177 Expected Life: 200,000 operations at full load. AC coil: 2 million operations, mechanical. DC coil: 5 million operations, mechanical. Consult factory for other voltages. Minimum Contact Load: 3A 120VAC. *Must operate is 75% of nominal voltage for any mounting position, applicable for vertical or horizontal mounting, but not for upside-down mounting. **Units requiring less power can be provided for some applications. Consult factory for details. Note: Coil suppression is recommended for all DC coil units, particularly 120 and 240VDC coils. Main Contact Ratings +25C, 60 Hz. Motor Rating in Amps, 33P or 12P Resistive Rating Type Full Load Locked Rotor (Electric Heat) 600V 240V 480V 600V 600V P25 25A 150A 125A 100A 30A Operate Data 25C Motor Rating in Horsepower Must-Operate Voltage: See coil data tables. Type 120V 240V 440-600V 12P 1.5HP 3HP 33P 3HP 7.5HP 10HP Notes: Models utilizing box lug terminals are restricted to the following ratings: 25 FLA, 150 LRA 250VAC 30A 277VAC Resistive Horsepower ratings shown in the table are valid up to 240VAC. Tungsten Lamp Rating: 30A, 277VAC. Environmental Data Electric Discharge Lamp Rating: 30A, 277VAC. Temperature Range: AC: 55C to +65C Heavy Duty Pilot Ratings 120V through 600V: 720VA max. (Box lug nut units limited to 277VAC.) DC: 55C to +55C Contact sales representative for higher Auxiliary Snap-Action Switch Arrangements: Up to 2 Form C (DPDT). temperature ratings. Rating: 10 amps at 120VAC, 60 Hz. 25C. Material: Silver. Initial Dielectric Strength Initial Breakdown Voltage: 2,200V rms. minimum between all elements Mechanical Data and between all elements and ground. Mounting: No. 10 screws on 2.125 (53.98mm) centers or universal mounting bracket. Termination: Contacts: 8-32 screw for No. 16 to No. 8 wire, dual .250 (6.35mm) Coil Data 25C quick connect, box lug or captive pressure plate. Coil: Combination 8-32 screw and .250 (6.35mm) or .187 (4.75mm) Voltage: From 6 to 240VDC and 24 to 600VAC, 50/60 Hz. quick connect, combination captive pressure plate and .250 Power: DC, 4-8W AC, 40VA inrush 10VA, sealed. (6.35mm) quick connect, or .250 (6.35mm) quick connect. Duty Cycle: Continuous. Aux. Switch: .187 (4.75mm) quick connect. Insulation Class: Class A, standard. Class B available. Weight: 14 oz. (397g). Initial Insulation Resistance: 100 megohms, minimum. Dimensions are shown for Dimensions are in inches over Specifications and availability www.tycoelectronics.com reference purposes only. (millimeters) unless otherwise subject to change. Technical support: 820 specified. Refer to inside back cover.Catalog 1308242 Issued 3-03 (PDF Rev. 5-05) P&B Ordering Information Typical Part No. B P25 P 42 A 1 4 P 1 -240 1. Type: P25 Definite Purpose Contactor 2. Auxiliary Switch: P = No Aux Switch C = 1 Form C (SPDT), silver contacts F = 2 Form C (DPDT), silver contacts Double pole contact forms require two switches. 3. Main Contact Arrangement: 42 = 3 Form X (3PST-NO-DM) 43 = 2 Form X (DPST-NO-DM) & 1 Form Y (SPST-NC-DB) Other contact arrangements are available. 4. Coil Control Input: A = Alternating Current, 50/60 Hz. D = Direct Current 5. Mounting and Installed Accessories: 1 = Without Mounting Plate* 2 = With Mounting Plate * Order separately any mounting hardware which is to be bulk packed. 6. Main Contact Terminals: 2 = 8-32 Screw Terminals 3 = Dual .250 (6.35mm) Quick Connect 5 = 8-32 Screw with Captive Pressure Plate 7. Auxiliary Contact Terminals: P = No Auxiliary Switch C = .187 (4.75mm) Quick Connect 8. Coil Terminals: 1 = Combination 8-32 Screw Terminal and .250 (6.35mm) Quick Connect 6-32 Screw Terminal available on DC Coils only. 9. Coil Voltage: 24, 120 or 240VAC 12 or 24VDC See Coil Data table. Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. P25P42A12P1-120 P25P42A12P1-240 P25P42A22P1-120 P25P42A22P1-240 P25P42D22P1-12 P25P42D22P1-24 Dimensions are shown for Dimensions are in inches over Specifications and availability www.tycoelectronics.com reference purposes only. (millimeters) unless otherwise subject to change. Technical support: 821 specified. Refer to inside back cover.