Catalog 1308242 Issued 3-03 (PDF Rev 4-04) AGASTAT STA series Specification Grade Discrete Plug-in Time Delay Relay With QC Terminals On-Delay, Off-Delay, Interval and Accumulating On-Delay timing modes 13 timing ranges from 0.1 sec. to 48 hr. 10A DPDT output contacts Knob, fixed or external timing adjustment. QC plug-in terminals save space, two LEDs show status File E60363 File LR51332 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Input Data 25C On-Delay, Off-Delay, Interval and Accumulating On-Delay. Voltage: See Ordering Information section for details. Power Requirement: 3W, max. Transient Protection: Non-repetitive transients of the following magni- Timing Specifications tudes will not cause spurious operation of affect function and accuracy. Timing Ranges: 6 to 180 cycles 0.1 to 3 / 0.5 to 15 / 1 to 30 / 2 to 60 / Operating Voltage <0.1 ms <1 ms 4 to 120 / 6 to 180 / 10 to 300 sec. 0.33 to 10 / 0.5 to 15 / All except 12 & 24 3,000V 2,500 1 to 30 min. 1 to 6 / 2 to 48 hr. (All are +5%, 0% of 12 & 24 Consult Factory maximum values). Timing Adjustment: Knob or fixed time (internal fixed resistor) all models Environmental Data customer supplied external potentiometer or resistor On-Delay and Interval models only. Temperature Range: Storage: -40C to +85C. Accuracy: Repeat Accuracy: .5% 0.004 sec.. Operating: -30C to +65C. Overall Accuracy: 2% throughout operating temperature and voltage ranges. Mechanical Data Reset Time: 30 ms. min. (between deenergization and reenergization Mounting/Termination: Quick connect terminals fit either 27E121 or without affecting accuracy.) 27E893 (snap-on) socket (order separately). Relay Operate Time: Off-Delay mode: 35 ms. Interval mode: 20 ms. Status Indication: Power On LED and Output Contacts LED (optional). Relay Release Time: On-Delay and Accumulating On-Delay modes: 20 ms. Weight: 4.2 oz. (119g) approximately. Ordering Information (AllX must be included to complete part number) Contact Data 25C Arrangements: 2 Form C (DPDT). RX S STA 01 2X A A XA Rating: 10A 28VDC or 120VAC, resistive 1/3 HP 120/240VAC 345VA. Same polarity. Expected Mechanical Life: 10 million operations. Status Series STA Operating Mode Timing Range Expected Electrical Life: 500,000 operations, min., at rated resistive load. Discrete 01 = On-Delay Indication A =0 .1 to 3 sec. S = LEDs Industrial 02 = Off-Delay B = 0.5 to 15 sec. Timer 03 = Interval X = No LEDs C = 1 to 30 sec. Initial Dielectric Strength With 09 = Accumulating D = 2 to 60 sec. Between Terminals and Case: 1,000VAC plus twice the nominal voltage Tab-type On-Delay E = 4 to 120 sec. for one minute. Terms. F = 6 to 180 sec. Output G = 10 to 300 sec. Outline Dimensions 2X = DPDT I = 2 to 60 min. Relay J = 1 to 6 hr. Mounting Series RX = 11-pin tab-type K = 3 to 180 cycles 1.500 MAX. L = 0.33 to 10 min. header (order (38) socket M = 0.5 to 15 min. N = 1 to 30 min. separately) .281 REF660 MAX. 3.045 1.390 MAX. R = 2 to 48 hr. (7) (17) (77) (35) Operating Voltage Timing Adjustment (+10%, 15%) XA = Knob Adjust Wiring Diagrams (Bottom Views) A = 120VAC, 50/60 XB = External Hz. / 120VDC Potentiometer or Insulated, shielded two-conductor E = 24VAC, 50/60 resistor (Operating cable similar to Belden 8719, 8720 or 8769 required for leads longer Hz. / 24VDC modes 1 and 3 than 6 inches. Maximum F = 48VAC, 50/60 only). permissble length is 50 feet. Hz. / 48VDC XF =Fixed Times Q = 12VDC Specify time delay in seconds per the following examples: XF9.000 = 9 sec. XF99.00 = 99 sec. XF999.0 = 9999 sec. XF1000 = 1000 sec. Off-Delay & On-Delay On-Delay Accumulating & & Authorized distributors are likely to stock the following: On-Delay Interval Interval Fixed or Knob Fixed or Knob External Potentiomer None at present. Adjust Adjust or Resistor Adjust Dimensions are shown for Dimensions are in inches over Specifications and availability www.tycoelectronics.com reference purposes only. (millimeters) unless otherwise subject to change. Technical support: 1236 specified. Refer to inside back cover.