200 W 100 W 50 W 25 W General Purpose Catalog 1308242 Low Power PCB Relays Potter & Brumfield Issued 3-03 (PDF Revised 8-06) P&B Sensitive, Low Profile, Hi-Current Low profile, PCB Relay T75 Series Relay Designed to Meet International Standards T75 series n 1 pole 8A, 1 form C (CO) or 1 form A (NO) contact n 4kV/8mm coil-contact 10 Amp, PC Board n Reinforced insulation (protection classII) Miniature Relay n Ambient temperature up to 85C at 8A File E29244 n Plastic materials according to IEC60335-1 (domestic appliances) File No. 3919 Users should thoroughly review the technical data before selecting a product part number. It Typical applications is recommended that user also seek out the pertinent approvals files of the agencies/ HVAC,security and industrial control, domestic appliances. laboratories and review them to ensure the product meets the requirements for a given application. Z Features Initial Dielectric Strength Approvals Coil Data High sensitivity nominal coil power requirement is as low as 212mW. Between Open Contacts: 1,000V rms. 2 2 Coil voltage range 3 to 60VDC Low profile, .591 in. (15mm) tall case uses only .465 in (3cm ) of area on the Between Contacts and Coil: 4,000V rms, 8mm. VDE Cert. No. 3919, UL E214025 Operative range, IEC 61810 2 Technical data of approved types on request. printed circuit board, permitting high density circuit design. Coil insulation system according UL classA Power switching capability contacts rated 10 amps in 1 Form A (SPST-NO) or 1 Coil versions, DC coil Form C (SPDT) arrangements. Coil Rated Operate Release Coil Rated coil Contact Data Designed to meet UL, CSA, VDE, SEMKO and SEV requirements. code voltage voltage voltage resistance power Contact arrangement 1 form C (CO) or 1 form A (NO) Designed to meet VDE 8mm spacing, 4kV dielectric, coil to contacts. 1) VDC VDC VDC 10% mW Coil Data Rated voltage 250VAC Designed to meet 3 mm creepage between contacts. 03 3 2.1 0.3 40 225 Max. switching voltage 400VAC Conforms to: VDE 0110 Insulation Group C (250V) Voltage: 3 to 60VDC. 05 5 3.4 0.5 118 212 Rated current 8A VDE 435 Part 201 High current applications Maximum Power 23C: 1W. 06 6 4.1 0.6 165 218 Limiting making current, max 4s, df 10% 15A VDE 0804 Telecommunications equipment Nominal Power 23C: 230mW, typ. 09 9 6.1 0.9 364 223 Breaking capacity max. 2000VA VDE 0631 Temperature controllers and limiters Temperature Rise: 85C per Watt. 12 12 8.2 1.2 652 221 Contact material AgCdO VDE 0700 Household appliances Duty Cycle: Continuous. 24 24 16.3 2.4 2270 254 Min. recommended contact load 100mA at 12VDC VDE 0805/5.90 Office machines 48 48 32.6 4.8 8790 262 Minimum switching voltage 5VDC 1) Wash tight (washable). 60 60 40.8 6.0 15265 236 Initial contact resistance 100m at 100mA, 12VDC -1 Well suited for a broad range of applications e.g. HVAC, appliances,1) Coil resistance 15%. Frequency of operation, with/without load 6/1200min Coil Data All figures are given for coil without pre-energization, at ambient temperature +23C. security and industrial control. Operate/release time max. 10/5ms Other coil voltages on request. DC Must Nominal Bounce time max., form A/form B 3/10ms Nominal Resistance Operate Coil Insulation Data Voltage in Ohms Voltage Current Electrical endurance 10% (mA) Contact Ratings 25C with relay properly vented. Type Contact Load Cycles 3 T75 8Arms, 240VAC, resistive 100x10 Remove vent nib after soldering and cleaning. 3 40 2.1 75.0 3 T75 A (NO) 14Arms, 120VAC, resistive 50x10 5 118 3.4 42.4 Arrangements: 1 Form A (SPST-NO) and 1 Form C (SPDT). 3 T75 B (NC) 5Arms, 120VAC, resistive 50x10 6 165 4.1 36.4 Material: Silver-cadmium oxide. 3 T75 7.2 FLA / 45 LRA, 120 VAC 30x10 DC 9 365 6.1 24.7 Expected Mechanical Life: 10 million operations. 3 T75 5 FLA / 30 LRA, 240 VAC 10x10 Coils 12 650 8.2 18.5 Expected Electrical Life: 18 1,455 12.3 12.4 100,000 operations at 8 amps, 240VAC. Contact ratings 24 2,270 16.3 10.6 50,000 operations at 14 amps NO / 5 amps NC, 120VAC Res. Type Contact Load Cycles 36 5,460 24.5 6.4 30,000 operations at 7.2 FLA, 45 LRA, 120VAC. 3 T75 A (NO) TV4, Tungsten, 120VAC, 40C 25x10 48 8,790 32.6 5.5 10,000 operations at 5 FLA, 30 LRA, 240VAC. 3 T75 C (CO) 10A, 240VAC, general purpose, 40C 6x10 60 15,265 40.8 3.9 3 30,000 operations at B300 pilot duty (360VA, 240VAC 470VA, 120VAC). T75 C (CO) 8A, 24VDC, general purpose, 40C 100x10 3 Contact Ratings (See Figure 1): T75 C (CO) 1/3HP, 120VAC, 40C 30x10 3 Maximum Switched Voltage: 380VAC. T75 C (CO) 1/2HP, 240VAC, 40C 30x10 Maximum Switched Current: 14/5 (N.O./N.C.) amps, AC resistive 6 8 amps DC (see Fig. 1) Mechanical endurance, DC coil 10x10 operations Maximum Switched Power: 200W, DC 2,000VA, AC. Operate Data 23C Minimum Required Contact Load: 12V, 100mA. Initial dielectric strength VDE Contact Ratings: 8 amps, 250VAC. Must Operate Voltage: 70% of nom. voltage or less. between open contacts 1000V rms UL Contact Ratings: 10 amps, 240VAC 8 amps 24VDC Must Release Voltage: 10% of nom. voltage or more. between contact and coil 4000V rms 1/3 HP, 120VAC 1/2 HP, 240VAC. Operate Time (Excluding Bounce): 6 ms, typ., at nom. voltage. Clearance/creepage Release Time (Excluding Bounce): 2.5 ms, typ., at nom. voltage. between contact and coil 8/8mm Maximum Switching Rate: 20 operations/second. Material group of insulation parts IIIa Figure 1 - DC Switching Load Limit Curve Maximum Continuous Operating Voltage: 225% of nom. voltage. 300 200 ENVIRONMENTAL DATA Temperature Range 100 Storage: -40C to +130C. Operating: -40C to +85C. 1 50 01-2015, Rev. 0115 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section, 40 www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are 30 2015 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change. a TE Connectivity Ltd. company. General Purpose Low Power PCB Relays Potter & Brumfield Low profile, PCB Relay T75 Series (Continued) Other Data PCB layout / terminal assignment Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at 1 form C, 1 CO contact, 3.2 mm www.te.com/customersupport/rohssupportcenter Ambient temperature - 40 to +85C Category of environmental protection IEC 61810 RTII - flux proof RTIII - wash tight Vibration resistance (functional) form A (NO) / form B (NC) 10/4g Vibration resistance (destructive) form A (NO) / form B (NC) 20/5g Shock resistance (destructive) 100g Terminal type PCB-THT Weight 11g Resistance to soldering heat THT IEC 60068-2-20 RTIII: 260C/5s Packaging/unit tube/20 pcs., box/1000 pcs. 1 form A, 1 NO contact, 5mm Dimensions 1 form C, 1 CO contact, 3.2 mm 1 form A, 1 NO contact, 5 mm 2 01-2015, Rev. 0115 Catalog and product specification according Catalog and product data is subject to the Catalog product data, Definitions section, www.te.com to IEC 61810-1 and to be used only together terms of the disclaimer and all chapters of application notes and all specifications are 2015 Tyco Electronics Corporation, with the Definitions section. the Definitions section, available at subject to change. a TE Connectivity Ltd. company.