Series 858, Relay Sockets with Industrial Relay Relay socket with industrial relay Relay socket with industrial relay Coil voltage: 24 V DC Coil voltage: 24 V DC 4 changeover contacts 4 changeover contacts (gold contacts) 14 14 11 11 12 12 24 24 A1 A1 21 21 - - 22 22 * In order to prevent the gold layer from being dam- 34 34 aged, these values shall not be exceeded. Higher 31 31 A2 A2 32 32 + + switching power leads to evaporation of the gold layer. 44 44 The resulting deposits in the enclosure may cause 41 41 42 42 sparkovers between the coil and the contact. Description Item No. Pack. Unit Item No. Pack. Unit Relay socket with industrial relay, for DIN 35 rail 858-304 1 858-314 1 Technical Data Coil Coil voltage 24 V DC 24 V DC Rated Power 0.9 W 0.9 W Coil Current 36.9 mA 36.9 mA Operating Range 0.8 - 1.1 x V 0.8 - 1.1 x V Holding Voltage 50% of V 50% of V N N Release Voltage 0.1 x V 0.1 x V Contacts Contact Material AgCe AgCe + 5 m Au Continuous Current 5 A 50 mA* Inrush Current 15 A/4 s 15 A/4 s Max. Switching Voltage 250 V AC/ 30 V DC 30 V DC * Switching Power (Max.) AC1/AC15 1250 VA/300 VA 1250 VA/300 VA 1-Phase Motor Load AC3 0.12 kW 0.12 kW Switching Current (Max.) DC1 5 A at 30 V DC 5 A at 30 V DC Min. Switching Load 12 V/100 mA 12 V/100 mA Switching Frequency Under Load 20 cycles/min. 20 cycles/min. General Specifications 6 6 Mechanical Life 20 x 10 switching operations 20 x 10 switching operations 5 5 Electrical Life 1 x 10 switching operations 1 x 10 switching operations Response Time/Drop-Out Time/Bounce Time (typ.) 25 ms/25 ms/4 ms 25 ms/25 ms/4 ms Nominal Voltage Acc. to VDE 0110 Part 1/4.97, 250 V/2.5 kV/2 250 V/2.5 kV/2 IEC 60664-1 Dielectric Strength Contact-Coil (1.2/50 s) 4 kV 4 kV Dielectric Strength Contact-Coil (AC, 1 min) 1.5 kV 1.5 kV Dielectric Strength Open Contact 1 kV 1 kV Dielectric Strength Contact-Contact 1.5 kV 1.5 kV o o o o Ambient Operating Temperature -25 C - +70 C -25 C - +70 C o o o o Storage Temperature -40 C - +80 C -40 C - +80 C Dimensions (mm) W x H x L 31 x 73 x 97, Height from upper-edge of DIN 35 rail 31 x 73 x 97, Height from upper-edge of DIN 35 rail Wire Connecion CAGE CLAMP S CAGE CLAMP S 2 2 2 2 2 2 Cross Sections 2 x 0.34 mm - 2 x 1.5 mm /1 x 2.5 mm /22 - 16 AWG 2 x 0.34 mm - 2 x 1.5 mm /1 x 2.5 mm /22 - 16 AWG Stripped Lengths 9 - 10 mm/0.37 in 9 - 10 mm/0.37 inSeries 858, Relay Sockets with Industrial Relay Relay socket with industrial relay Relay socket with industrial relay Coil voltage: 120 V AC Coil voltage: 120 V AC 4 changeover contacts 4 changeover contacts (gold contacts) 14 14 11 11 12 12 24 24 A1 A1 21 21 ~ ~ 22 22 * In order to prevent the gold layer from being dam- 34 34 aged, these values shall not be exceeded. Higher 31 31 A2 A2 32 32 ~ ~ switching power leads to evaporation of the gold layer. 44 44 The resulting deposits in the enclosure may cause 41 41 42 42 sparkovers between the coil and the contact. Description Item No. Pack. Unit Item No. Pack. Unit Relay socket with industrial relay, for DIN 35 rail 858-507 1 858-517 1 Technical Data Coil Coil voltage 120 V AC 120 V AC Rated Power 1.2 VA 1.2 VA Coil Current 15 mA 15 mA Operating Range 0.8 - 1.1 x V 0.8 - 1.1 x V Holding Voltage 80% of V 80% of V N N Release Voltage 0.3 x V 0.3 x V Contacts Contact Material AgCe AgCe + 5 m Au Continuous Current 5 A 50 mA* Inrush Current 15 A/4 s 15 A/4 s Max. Switching Voltage 250 V AC/ 30 V DC 30 V DC * Switching Power (Max.) AC1/AC15 1250 VA/300 VA 1250 VA/300 VA 1-Phase Motor Load AC3 0.12 kW 0.12 kW Switching Current (Max.) DC1 5 A at 30 V DC 5 A at 30 V DC Min. Switching Load 12 V/100 mA 12 V/100 mA Switching Frequency Under Load 20 cycles/min. 20 cycles/min. General Specifications 6 6 Mechanical Life 20 x 10 switching operations 20 x 10 switching operations 5 5 Electrical Life 1 x 10 switching operations 1 x 10 switching operations Response Time/Drop-Out Time/Bounce Time (typ.) 25 ms/25 ms/4 ms 25 ms/25 ms/4 ms Nominal Voltage Acc. to VDE 0110 Part 1/4.97, 250 V/2.5 kV/2 250 V/2.5 kV/2 IEC 60664-1 Dielectric Strength Contact-Coil (1.2/50 s) 4 kV 4 kV Dielectric Strength Contact-Coil (AC, 1 min) 1.5 kV 1.5 kV Dielectric Strength Open Contact 1 kV 1 kV Dielectric Strength Contact-Contact 1.5 kV 1.5 kV o o o o Ambient Operating Temperature -25 C - +70 C -25 C - +70 C o o o o Storage Temperature -40 C - +80 C -40 C - +80 C Dimensions (mm) W x H x L 31 x 73 x 97, Height from upper-edge of DIN 35 rail 31 x 73 x 97, Height from upper-edge of DIN 35 rail Wire Connecion CAGE CLAMP S CAGE CLAMP S 2 2 2 2 2 2 Cross Sections 2 x 0.34 mm - 2 x 1.5 mm /1 x 2.5 mm /22 - 16 AWG 2 x 0.34 mm - 2 x 1.5 mm /1 x 2.5 mm /22 - 16 AWG Stripped Lengths 9 - 10 mm/0.37 in 9 - 10 mm/0.37 in