67 Series - Solar relay 50 A Features 67.22-4300 67.23-4300 Printed circuit mount 50 A Power relay for photovoltaic inverters 2 and 3 pole versions (NO, double break contacts) Contact gap 3 mm, according to VDE 0126-1-1, EN 62109-1, EN 62109-2 DC coils, with only 170 mW holding power Reinforced insulation between coil and contacts 1.5 mm gap between PCB and relay base 2 NO 3 NO Suitable for use at ambient temperatures up to Contact gap 3 mm Contact gap 3 mm 85 C (with energy-saving coil energization) PCB mount PCB mount or 70 C (with standard coil energization) For outline drawing see page 5 Copper side view Copper side view Contact specification Contact configuration 2 NO (DPST-NO) 3 NO (3PST-NO) Contact gap 3 mm 3 mm Rated current/Maximum peak current (for 5 ms) A 50/150 50/150 Rated voltage/Maximum switching voltage V AC 400/690 400/690 Rated load AC1/AC-7a VA 20,000 20,000 Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10) Standard contact material AgSnO AgSnO 2 2 Coil specification Nominal voltage (U )V DC 5 - 6 - 8 - 12 - 24 - 48 - 60 - 110 5 - 6 - 8 - 12 - 24 - 48 - 60 - 110 N Rated power W 1.7 1.7 Operating range (4070C) (0.90 1.1) U (0.90 1.1) U N N for 1 (4085C) (0.952.5) U (0.952.5) U N N Minimum pull-in power W 1.5 1.5 Holding voltage range (4085C) (0.32...0.65) U (0.32...0.65) U N N Minimum holding power W 0.17 0.17 Must drop-out voltage 0.05 U 0.05 U N N Technical data 6 6 Mechanical life cycles 1 10 1 10 3 3 Electrical life at rated load AC-7a cycles 30 10 30 10 Operate/release time ms 35/4 35/4 Ambient temperature range C 40+85 40+85 Environmental protection RTII RTII Overall dimensions mm 33 x 51.5 x 57.5 33 x 51.5 x 57.5 Approvals (according to type) 1 VII-2012, www.findernet.com67 Series - Solar relay 50 A Features 67.22-4500 67.23-4500 Printed circuit mount 50 A Power relay for photovoltaic inverters 2 and 3 pole versions, NO double break contacts Contact gap 5.2 mm (according to VDE 0126-1-1, EN 62109-1, EN 62109-2) Suitable for inverters with DC input up to 1,500 V and AC output up to 690 V, installations up to 4,000 m on sea level DC coils, with only 170 mW holding power 2 NO 3 NO Reinforced insulation between coil and contacts Contact gap 5.2 mm Contact gap 5.2 mm 1.5 mm gap between PCB and relay base PCB mount PCB mount Suitable for use at ambient temperatures up to 85 C (with energy-saving coil energization) or 60 C (with standard coil energization) Copper side view For outline drawing see page 5 Copper side view Contact specification Contact configuration 2 NO (DPST-NO) 3 NO (3PST-NO) Contact gap 5.2 mm 5.2 mm Rated current/Maximum peak current (for 5 ms) A 50/150 50/150 Rated voltage/Maximum switching voltage V AC 400/690 400/690 Rated load AC1/AC-7a VA 20,000 20,000 Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10) Standard contact material AgSnO AgSnO 2 2 Coil specification Nominal voltage (U )V DC 5 - 6 - 8 - 12 - 24 - 48 - 60 - 110 5 - 6 - 8 - 12 - 24 - 48 - 60 - 110 N Rated power W 2.7 2.7 Operating range (4060C) (0.90 1.1) U (0.90 1.1) U N N for 1 (4085C) (0.952.5) U (0.952.5) U N N Minimum pull-in power W 2.4 2.4 Holding voltage range (4085C) (0.25...0.5) U (0.25...0.5) U N N Minimum holding power W 0.17 0.17 Must drop-out voltage 0.05 U 0.05 U N N Technical data 6 6 Mechanical life cycles 1 10 1 10 3 3 Electrical life at rated load AC-7a cycles 30 10 30 10 Operate/release time ms 30/4 30/4 Ambient temperature range C 40+85 40+85 Environmental protection RTII RTII Overall dimensions mm 33 x 51.5 x 57.5 33 x 51.5 x 57.5 Approvals (according to type) 2 VII-2012, www.findernet.com