General Purpose Relays Industrial Relays Potter & Brumfield W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers n Designed for the international market. UL Recognzied (UL1077 and UL1500), CSA Accepted and VDE approved. n Ratings to 50 amps. n Heavy duty 10-32 stud connections. (W9) n Quick-connect or screw terminals. (W6) n Several delay curve options. n Trip-free operation. Agency Approvals UL: Recognized as Supplementary Protector under UL 1077. Available Mechanical/Environmental Data (continued) models meet Ignition Protection requirements in accordance with Fungus and Moisture Resistance: UL1500. File E69543 Special moisture resistant finish applied to all ferrous parts. CSA: Accepted as a Supplementary Protector. File LR15734. Plastic parts are made of inherently fungus resistant material. VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment) Marking: License No. 73782 International 1 and 0 symbols are marked on the toggle for both W6 and Users should thoroughly review the technical data before selecting a product part number. W9. W9 units have ON and OFF molded into the area at the base of the It is recommended that users also seek out the pertinent approvals files of the agencies/ toggle. laboratories and review them to confirm the product meets the requirements for a given Mounting: application. Units are mounted with two 6-32 screws from the front of the panel. Metric models for use with M3 x 0.5 screws are available. To maintain Electrical Data published performance specifications, units should not be mounted more Calibration: than 90 from their normal upright position. Breakers will hold 100% of rated current. Weight: Approximately 2.5 ounces per pole. Breakers may trip between 101% and 124% of rated load (134% for AC/ DC units). Breakers must trip at 125% of rated load and above (135% for AC/DC Approvals and Ratings Table 1 units). Dielectric Strength: 50/60 Hz., 1500V: DC, 1100V Insulation Resistance: 100 Megaohms at 500VDC W6 Series UL1077/CSA (All Circuit Functions) Endurance: Current Interrupting 10,000 on/off cycles - 6000 at rated load, 4000 at no load. Maximum Frequency Phase Rating Capacity Units tested at six cycles per minute, 1 second on and 9 seconds off at Voltage (Hz) (Amps) (Amps) 25C ambient. 65 DC - 0.2 - 50 2,000 277 50/60 1 0.2 - 20 5,000 Typical Resistance and Impedance 277 50/60 1 21 - 50 2,500 Current DC 50/60 277/480 50/60 3-Wye 0.2 - 20 5,000 (Amps.) Resistance Impedance (Ohms) (Ohms) W9 Series UL1077/CSA (All Circuit Functions) 0.2 90 90 1.0 1.2 1.2 Current Interrupting Maximum Frequency 2.0 0.28 0.28 Phase Rating Capacity Voltage (Hz) 5.0 0.04 0.04 (Amps) (Amps) 10.0 0.013 0.013 65 DC - 0.2 - 50 2,000 20.0 0.004 0.005 277 50/60 1 0.2 - 50 5,000 30.0 0.0027 0.004 277/480 50/60 3-Wye 0.2 - 20 5,000 40.0 0.002 0.002 50.0 0.0015 0.0015 W6 or W9 Series VDE (Circuit Function X) Tolerance: 0.1 - 4.99 15% 5 - 9.99 20% 10 - 15 25% 16 - 30 50%. Current Interrupting Maximum Frequency Phase Rating Capacity Voltage (Hz) (Amps) (Amps) Mechanical/Environmental Data Operating Temperature: -40C to +85C. 65 DC - 0.2 - 50 2,000 Humidity: Meets requirements of Mil-STD-202 method 103. 250 50/60 1 0.2 - 30 5,000 Shock: Tested per Mil-STD-202, method 213, test condition C 250 50/60 1 31 - 50 2,000 (100g 6 ms) 415/240 50/60 3 0.2 - 30 5,000 Vibration: Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06 (1.52mm) total excursion in 2 planes. W6 or W9 Series UL1500 (Circuit Function X) Current Interrupting Maximum Frequency Phase Rating Capacity Voltage (Hz) (Amps) (Amps) 48 DC - 0.2 - 50 3,000 125/250 50/60 1 0.2 - 50 1,000 250 50/60 3-Wye 0.2 - 50 1,000 1 11-2015, Rev. 1115 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2014 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company General Purpose Relays Industrial Relays Potter & Brumfield W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers (Continued) Time vs Current Trip Curves For W6 Series and W9 Series AC 50/60 Hz. DC & 50/60 Hz. 400 Hz. CURVE 3 SHORT DELAY 50/60 Hz. CURVE 0 INSTANTANEOUS CURVE 2 STANDARD DELAY 50/60 Hz. 10,000 10,000 TRIP TIMES 10,000 OVERLOAD TRIP TIMES OVERLOAD TRIP TIMES (SEC.) OVERLOAD 50/60 Hz. & DC 400 Hz. 1000 (SEC.) 1000 1000 125% 1 - 15 125% 100 ms max. May Trip 125% 10 - 150 200% .15 - 1.5 150% 55 ms max. 100 ms max. 100 200% 2.2 - 20 100 100 400% .03 - .25 200% 30 ms max. 30 ms max. 400% .2 - 2 600% .007 - .15 400% 15 ms max. 15 ms max. 10 600% .03 - .75 10 800% .003 - .08 600% 12 ms max. 12 ms max. 10 800% .007 - .15 1000% .003 - .04 800% 12 ms max. 12 ms max. 1000% .005 - .04 1 1 1 .1 .1 .1 .01 .01 .01 .001 .001 .001 100 200 300 400 500 600 700 800 900 1000 1100 1200 100 200 300 400 500 600 700 800 900 1000 1100 1200 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 0 125 150 LOAD CURRENT AS A PERCENT 125 150 0 LOAD CURRENT AS A PERCENT 125 150 LOAD CURRENT AS A PERCENT OF BREAKER RATING OF BREAKER RATING OF BREAKER RATING MOTOR START / LONG DELAY CURVE 12 HIGH INRUSH 50/60 Hz. CURVE 13 HIGH INRUSH 50/60 Hz. 10,000 CURVE 10 HIGH INRUSH 50/60 Hz. AC 10,000 10,000 OVERLOAD TRIP TIMES OVERLOAD TRIP TIMES OVERLOAD TRIP TIMES (SEC.) (SEC.) (SEC.) 1000 1000 125% 10 - 150 1000 125% 40 - 500 125% .8 - 30 200% 9 - 100 200% 3 - 25 100 200% .15 - 2.5 400% 2 - 20 100 400% .5 - 2.5 100 400% .03 - .3 600% .8 - 10 600% .15 - 1 800% .1 - 4.5 600% .02 - .15 10 1000% .009 - 2 800% .015 - .7 10 800% .009 - .12 10 1000% .009 - .35 1000% .009 - .09 1 1 1 .1 .1 .1 .01 .01 .01 .001 100 200 300 400 500 600 700 800 900 1000 1100.0 011200 .001 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 100 200 300 400 500 600 700 800 900 1000 1100 1200 125 150 0 LOAD CURRENT AS A PERCENT 125 150 0 LOAD CURRENT AS A PERCENT 125 150 OF BREAKER RATING LOAD CURRENT AS A PERCENT OF BREAKER RATING OF BREAKER RATING DC CURVE 3 SHORT DELAY DC CURVE 2 STANDARD DELAY DC CURVE 53 DC HIGH INRUSH 10,000 10,000 10,000 OVERLOAD TRIP TIMES OVERLOAD TRIP TIMES OVERLOAD TRIP TIMES (SEC.) (SEC.) (SEC.) 1000 1000 1000 125% .6 - 7 125% 80 - 700 125% 2 - 55 200% 15 - 150 200% .16 - 1.5 200% .60 - 8 100 100 400% 2 - 20 400% .03 - .25 100 400% .1 - 1.5 600% .70 - 10 600% .01 - .13 600% .02 - .5 800% .10 - 3 10 10 800% .004 - .05 1000% .01 - .1 800% .004 - .05 10 1000% .003 - .015 1000% .004 - .025 1 1 1 .1 .1 .1 .01 .01 .01 .001 .001 100 200 300 400 500 600 700 800 900 1000 1100 1200 100 200 300 400 500 600 700 800 900 1000 1100 1200 .001 0 0 125 150 125 150 LOAD CURRENT AS A PERCENT 100 200 300 400 500 600 700 800 900 1000 1100 1200 LOAD CURRENT AS A PERCENT 0 OF BREAKER RATING 125 150 OF BREAKER RATING LOAD CURRENT AS A PERCENT OF BREAKER RATING AC/DC CURVE 34 DC, 50/60 Hz. STANDARD DELAY 10,000 OVERLOAD TRIP TIMES (SEC.) 1000 135% 1 - 90 200% .60 - 20 100 400% .095 - 2 600% .02 - .95 10 800% .002 - .45 1000% .002 - .09 1 .1 .01 .001 100 200 300 400 500 600 700 800 900 1000 1100 1200 0 125 150 LOAD CURRENT AS A PERCENT 135 OF BREAKER RATING Note: For instantaneous curves for all voltages refer to Curve 0 instananeous under the AC 50/60 Hz. heading 2 11-2015, Rev. 1115 Datasheets and product specification Datasheets and product data is subject to the Datasheets, product data, Definitions sec - www.te.com according to IEC 61810-1 and to be used terms of the disclaimer and all chapters of tion, application notes and all specifications 2014 Tyco Electronics Corporation, only together with the Definitions section. the Definitions section, available at are subject to change. a TE Connectivity Ltd. company