Introducing SCHRACK XT Series Interface Plug-in RelaySCHRACK XT Series Interface Plug-in Relays KEY FEATURES DESCRIPTION Slim, compact general purpose relay in one or two pole configurations for Choice of 1 form C (SPDT) plug-in mounting. or 2 form C (DPDT) models APPLICATIONS SPDT rated 16A 240VAC DPDT rated 8A 240VAC Panel interface applications in industrial machinery and other systems. Plugs into same sockets as MECHANICAL our RT series relays Robust terminals withstand plugging, unplugging. Sensitive DC coil (400mW) Optional mechanical test lever which may be customized for momentary or locking operation. or AC coil (.58VA 60Hz) Compact design is only .54 STANDARDS AND SPECS in (13.7 mm) wide UL Recognized for the US and Canada, file number E214025. VDE approved, registration number B758. Test lever, mechanical indica- tor, LED indicator and pro- tection diode options ELECTRICAL Contact Data 4kV (8mm) coil-to-contact Contact Arrangements & Ratings: 1 Form C (SPDT) rated 16A 240VAC isolation 2 Form C (DPDT) rated 8A 240VAC. Contact Material: Silver Nickel 90/10 Expected Life: 50,000 operations with DC coil at rated load Reinforced insulation, pro- 30,000 operations with AC coil at rated load. tection class II (VDE 0700) Coil Data Coil Voltage: 12 to 110VDC and 24 to 230VAC. Others on request. Coil Power: 400mW 0.76VA 50 Hz. / 0.58VA 60 Hz Initial Dielectric Strength Coil-to-Contacts: 5,000Vrms, when used with socket RT78726 4,000Vrms, when used with socket RT78725. Between Open Contacts: 1,000Vrms. Between Poles: 2,500Vrms. ENVIRONMENTAL RoHS Operating Temperature Range: -40C to +70C. Vibration Resistance (functional): 20G, 30-500Hz for NO contact Ready 5G, 30-500 Hz for NC contact. Shock Resistance (destructive): 100G. Tyco Electronics I XT Series Relay