xx Operating Information Standard Accessories Item Description The P5100A Probe is a high impedance probe with Theprobe includes the accessories shown below. Crocodile clip 100X attenuation that is designed for use with Tektronix Attach the clip to the banana WARNING. Do not substitute accessories from other ground-referenced oscilloscopes. end of the common lead and products for use with this probe. Only use the then to your circuit common. Connect theprobeasshownintheillustrationsbelow. accessories that are included with this probe. To avoid electric shock when using the probe or Reorder Tektronix part number accessories, keep your ngers behind the nger guard 344-0461-xx oftheprobebodyandawayfromtheshadedareashown in the accessory illustrations below. Common spring(TACS) Item Description Use this accessory to limit aberrations on high frequency Small hook tip (TASH) signals caused by common Use this tip to access test lead path inductance. points in tight spaces. Screw Bend the spring to reach the hook tip onto the probe tip nearby connections (~1 in). and then clamp the hook onto the circuit. Rating: 1000 V CAT II Reorder Tektronix part number 214-5299-xx Note: Only the 1000 V CAT II P5100A rating is applicable when used 500 MHz 100X High Voltage Probe Color bands with the P5100A probe Compensating the Probe Use these bands to identify Instructions the oscilloscope channel at the Due to variations in oscilloscope input characteristics, Reorder Tektronix part number probe head. the low-frequency compensation of the probe may need 013-0388-xx adjustmentafteryoumovetheprobefromoneoscilloscope Large hook tip (TALH) channel to another. Screw the hook tip onto the 1. Connecttheprobetotheoscilloscopechannelthatyou probe tip and then clamp the plan to use for your measurements. Reorder Tektronix part number hook onto the circuit. 016-1886-xx (5 pairs) 2. Connect the probe to the probe compensation output Rating: 1000 V CAT II terminals on the oscilloscope front panel. Note: Only the 1000 V CAT II Adjustment tool rating is applicable when used WARNING. To avoid electric shock, only connect to the Use only this insulated tool for with the P5100A probe Probe Comp signal on the oscilloscope when making compensation adjustments. this adjustment. To avoid electric shock, only use the Reorder Tektronix part number insulated adjustment tool when making compensation 003-1433-xx adjustments. Reorder Tektronix part number 013-0389-xx Optional Accessories 3. PushAUTOSETorotherwiseadjustyouroscilloscope to display a stable waveform. Commonleads The accessories shown below are available for the probe (6 in and 18 in) (TACL) and are rated 30 Vunlessindicated otherwise. Slide the lead over the probe head and snap it into place. Accessory Partnumber Connect the banana plug BNC toTipAdapter, 013-0291-xx end directly to your circuit Unterminated common, or use the crocodile clip included with the probe. Rubber Spring Tip 206-0060-xx Reorder Tektronix part 4. Adjustthetrimmerintheprobeuntilyouseeaperfectly numbers: Probe Holder TPH1000 at-topsquarewaveonthedisplay. (Seeillustration.) 6 inch: 196-3526-xx 18 inch: 196-3527-xx *P071288203* x 071-2882-03Service Information Avoid Exposed Circuitry and Do Not Operate Without Characteristics Description Covers. Donottouchexposedconnectionsandcomponents Performance verication and adjustment procedures Additional UL61010-031 2010 when power is present. are available on the Tektronix Web site. Go to Safety CAN/CSA C22.2 No. 61010-031:07/A1:2010 www.tektronix.com/manuals and enter P5100A in the Standards IEC61010-031 IEC 61010-031/A1:2008 Inspect The Probe and Accessories. Before each use, search eld. This product complies EquipmentRecycling. inspect probe and accessories for damage (cuts, tears, with the European Unions requirements defects in the probe body, accessories, cable jacket, etc.). Specications according to Directive 2002/96/EC on waste Do not use if damaged. electrical and electronic equipment (WEEE). Table 1: Electrical and mechanical specications For more information about recycling options, Do Not Operate in Wet/Damp Conditions. System bandwidth (3 dB, typical) 500 MHz check the Support/Service section of the Do Not Operate in an Explosive Atmosphere. Tektronix Web site (www.tektronix.com). System rise time (typical) <700 ps Keep Product Surfaces Clean and Dry. 2.5 pF System input capacitance Safety Terms and Symbols Terms inThis Manual. Table 2: Environmental specications Safety Summary Compensation range 730 pF These terms may appear in this manual: Reviewthefollowingsafetyprecautionstoavoidinjuryand Characteristics Description Propagation delay ~6.1 ns prevent damage to this product or any products connected WARNING. Warning statements identify conditions or Temperature to it. To avoid potential hazards, use this product only as practices that could result in injury or loss of life. System attenuation accuracy 100:1 1.75% specied. Using the probe or accessories in a manner not Operating 0Cto+50C(+32Fto+122F) System input resistance (typical) 40 M 1% CAUTION. Caution statements identify conditions or specied could result in a shock orre hazard. Nonoperating 40 C to +71 C (40 F to +159.8 F) Cable length 2m practices that could result in damage to this product or Humidity other property. To Avoid Fire or Personal Injury Maximum inputvoltage 1000 VRMS CAT II, Operating 5% to 95% relative humidity (%RH) up to (see Performance Graphs) 2500 V pk Ground-Referenced Oscilloscope Use. Do not oat the Symbols on the Product. These symbols may appear on +30 C, 5% to 75% RH above +30 C up reference lead of this probe when using with ground the product: to +50 C. Noncondensing referenced oscilloscopes (for example, DPO, MSO, and Performance Graphs Nonoperating 5% to 95% RH up to+30 C TDS series oscilloscopes). The reference lead must be 5% to 75% RH above+30 C to +65 C connected to earth potential (0 V). 5%to45%RHabove+65Cupto+71C. Noncondensing ConnectandDisconnectProperly. Connecttheprobeoutput tothemeasurementinstrumentbeforeconnectingtheprobe Altitude Operating: up to 3000 m (9842 ft) to the circuit under test. Disconnect the probe input and Nonoperating: up to 15420 m (50,000 ft) Contacting Tektronix the probe reference lead from the circuit under test before Web site: www.tektronix.com disconnectingtheprobefromthemeasurementinstrument. Table 3: Certications and compliances Phone: 1-800-833-9200 AvoidElectric Shock. To avoidinjuryorlossoflife,do not Address: Tektronix, Inc. connect or disconnect probes or test leads while they are Characteristics Description Department or name (if known) connected to a voltage source. EC Compliance wasdemonstrated to the following 14200 SW Karl Braun Drive Declaration specication as listed in the Ofcial Journal of ObserveAllTerminalRatings. Toavoidreorshockhazard, P.O. Box 500 of the European Communities: Beaverton, OR 97077 USA observe all ratings and markings on the product. Consult Conformity the product manual for further ratings information before Low Voltage Directive 2006/95/EC: Email: techsupport tektronix.com making connections to the product. EN61010-031/A1: 2008 Measurement CAT III: Distribution-level mains, xed AvoidElectricShock. Whenusing probeaccessories,never Warranty Information Category installation exceed the lowest rating of the probe or its accessory, For warranty information, go to Product CAT II: Local-level mains, appliances, portable whichever is less,includingthemeasurement category and www.tektronix.com/warranty. Examples equipment voltage rating. CATI:Circuits notdirectlyconnectedtomains. To avoid injury orre hazard, do Avoid Electric Overload. Pollution Donotoperate in environments wherecond- not apply potential to any input, including the reference Degree 2 uctive pollutantsmaybe present (asdened in inputs,that variesfrom groundby morethan the maximum IEC 61010-1). Rated for indoor use only. rating for that input. CopyrightTektronix,Inc. Allrightsreserved. www.tektronix.com