Series LPD60 250mA, 60Vdc Optically Isolated Dual Relay Part Number Description LPD60 .25A, 60Vdc dual solid-state relay MECHANICAL SPECIFICATION 0.79 0.140 (20.07) .005 (3.556 0.127) TELEDYNE FEATURES/BENEFITS LPD60 0.330 .005 Compact SIP plastic package 0.370 MAX (8.382 0.127) RELAY A RELAY B (9.398) Dual output: two relays in one package 0.020 MIN IN OUT IN OUT (0.508) + + + + Current limiting output - - - - Low voltage drop 0.180 MIN (4.572) DESCRIPTION The LPD60 is a dual-output 60Vdc plastic relay. The 0.025 ( .003) (0.6035 .076) WEIGHT: relay utilizes optical isolation to provide excellent 0.07 oz. (2g) input-to-output isolation. The LPD60 provides a 0.700 (20.32) current limiting output to protect itself and associated 0.025 .003 load circuits from transient current overloads. The (0.635 0.0762) .100 0.045 .005 compact size of the LPD60 occupies minimum board .005 (1.143 0.127) (2.54 0.127) space. The LPD60 is epoxy encapsulated for added ruggedness. Figure 1 LPD60 relay dimensions in inches (mm) APPLICATIONS Interface applications INPUT (CONTROL) SPECIFICATIONS Aircraft flight control systems Min Max Units A.T.E Control Voltage Range 4.0 7.0 Vdc 28Vdc aircraft instrumentation systems (See Note 1) Input Current 5 Vdc (See Figure 2) 12 mA Must Turn-On Voltage 4 Vdc Must Turn-Off Voltage 0.8 Vdc Must Turn-Off Current 50 Adc RELAY A RELAY B Reverse Voltage 7 Vdc IN OUT IN OUT + ++ + 14 23 4 5 6 7 8 PIN 1 12 10 +5Vdc 8 +V 6 4 V supply 2448 Vdc Load Load 2 Typical A B +V 0 012345678 Input Voltage (Vdc) INPUT CURRENT VS. INPUT VOLTAGE TYPICAL WIRING DIAGRAM Figure 2 Figure 3 LPD60 26 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2002 TELEDYNE RELAYS LPD60 072002 Q1 Input Current (mA)Series LPD60 0.250 OUTPUT (LOAD) SPECIFICATION Min Max Units 0.225 Load Voltage Rating 60 Vdc 0.20 Load Current Range (See Figure 6) 0.25 Adc Transient Blocking Voltage 80 Vdc 0.175 Output Capacitance 25Vdc 200 pF 0.150 On-State Voltage Drop (See Figure 4) 0.5 Vdc On Resistance 2.0 Ohm 0.125 Off-State Leakage Current (60 Vdc) 10 Adc 0.10 Turn-On Time 2.5 ms 0.70 Turn-Off Time 1 ms Overload Current Limit (See Figure 5) 0.8 Adc 0.05 Overload Time 30Vdc (See Figure 7) 0.2 sec 0.025 0 ENVIRONMENTAL SPECIFICATION 0 0.08 0.16 0.24 0.32 0.40 0.48 Min Max Units Output Voltage Drop (V) Operating Temperature 40 +85 C LOAD CURRENT VS. OUTPUT VOLTAGE DROP Storage Temperature 55 +100 C OVER TEMPERATURE Junction Temperature 100 C Figure 4 Thermal Resistance (Junction to Ambient) each relay 120 C/W 0.8 0.7 Shock 1500 g 0.6 Vibration 100 g 0.5 Dielectric Strength 500 Vac 0.4 Insulation Resistance 9 0.3 ( 500 Vdc) 10 Ohm 0.2 Isolation 5 pF 40 30 20 10 0 10 2030405060708090 Resistance to Ambient Temperature (C) Soldering Heat MIL STD 202, method 210 OVERLOAD CURRENT VS. TEMPERATURE Solderability MIL STD 202, method 208 Figure 5 Thermal Shock MIL STD 202, method 107 Altitude 55,000 ft HAST JDEC Test Method A110 0.3 130C 85% RH, no power 0.25 applied, 50 hours 0.2 0.15 0.1 0.05 0 40 20 0 20 40 60 80 100 120 Ambient Temperature (C) LOAD CURRENT VS. AMBIENT TEMPERATURE Figure 6 2002 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com LPD60 27 LPD60 072002 Q1 +85C 40C +25C Overload Current Limit (A) Load Current (A) Load Current (A)