PRODUCT FAMILY DESCRIPTION SEMI ISOLATED OUTLET : TSO-200 INDOOR RF PASSIVES FEATURES >> Frequency range 5-1006 MHz >> Class A screening effectiveness >> Outstanding RF performance >> R/TV and Data ports >> Low loss diplex filters SPECIFICATIONS INSERTION LOSS (dB, Max.) - IN to R/TV Frequency (MHz) Typ. 85 - 1006 4.3 4.8 INSERTION LOSS (dB, Max.) DATA to IN 5 - 65 0.8 1.3 INSERTION LOSS (dB, Max.) IN to DATA 85 - 1006 4.3 4.8 RETURN LOSS (dB, Min.) IN Port 5 - 65 18.0 (1) 85 - 1006 18.0 RETURN LOSS (dB, Min.) DATA Port 5 - 65 18.0 (1) 85 - 1006 18.0 RETURN LOSS (dB, Min.) R/TV Port (1) 85 - 1006 18.0 ISOLATION (dB, Min.) R/TV to DATA 5 65 45.0 85 862 22.0 862 1006 20.0 Teleste reserves the rights to alter specifications, features, manufacturing released and even the general availability of the product at any time. Rev.: TSO 200 SPEC 150827 1 www.teleste.com SPECIFICATIONS GENERAL SPECIFICATIONS Frequency range 5 1006 MHz Nominal impedance 75 Ohm Connectors Input Cable clamp R/TV outp ut IEC male DATA input/output IEC female Dimensions 69 x 64,5 x 29 mm Weight 0,094 kg (2) Electromagnetic compatibility (dB, Min.) 5 - 300 85.0 300 - 470 80.0 470 - 950 75.0 This terminal outlet has been 950 - 1006 55.0 designed to fit with the typical (3) (a) Intermodulation f1 + f2 110.0 (b) frames and covers. Combining (dBc, Min. ) 110.0 (c) 110.0 the high screening with the easy frontal cable connection Safety Isolation Inner conductor input to inner conductor output results in reliable and swift (4) installation. It features a R/TV 2120 VDC 0.7 mA, 1 minute port with downstream only and (4) 230 VAC RMS, 50/60 Hz 8.0 mA RMS a DATA port with both up and (5) Surge immunity 1 kV, 1.2/50S downstream. Housing (material/plating) Zinc die-cast / nickel plated Steel back lid / tin plated Connectors (material/plating) (6) Pin of IEC male Brass/Nickel Spring of IEC female Phosphor/Bronze Product approval CE EMC compatibility EN 50083-2 Notes (1) * F > 40 MHz -1.5 dB/oct (2) Class A, according to IEC 60728-2 2010, EMC (3) Two carriers (60 & 65 MHz), applied to (each)output port, 120dBV (a) No surge (b) Measured after 10 pulses 25V(1,2/500S applied to each port (c) Measured after 1 pulse 1kV (1,2/50S) applied to each port (4) According to IEC-60728-11 2007, Safety (5) Surge voltage according to IEC 61000-4-5, EMC (class 2, level 2) applied between the inner and outer conductor of each port (6) Dim ensions in accordance with IEC 61169-2, Coaxial connectors of type 9,52 Teleste reserves the rights to alter specifications, features, manufacturing released and even the general availability of the product at any time. Rev.: TSO 200 SPEC 150827 2 www.teleste.com