I gather a 2.5 mm flat-bladed screwdriver, a stranded or solid wire with the specifications below, and a tool to strip the wire. I strip the end of the wire on 7 mm typically (4 mm at least). 2.1 mm maxi.. Specifications of the wire. 1.50 mm maxi. (approximately 16 AWG). 19 28 mm. Strands. 7 mm typically (4 mm mini.). 5.1 mm maxi.. Jacket(s). If the plastic part is screwed on the metal part then I unscrew it and Cross-section of the plastic part, separate them. depth of the wire strain-relief : 15 mm. With the screwdriver I unscrew the screw without removing it. I slip the stripped end of the wire into the hole of the metal part until it abuts. Metal part. Plastic part. With the screwdriver I screw and tighten (2.3 N.m maxi. torque) the screw on the end of the wire. I insert the metal part into the plastic part I push the metal until it abuts 11 against the plastic part. I hold the metal part, I hold the plastic part, I rotate to screw until the metal part abuts against the plastic part (2.3 N.m maxi. torque). The 4 mm banana male The design and the Screw to attach Hole to slip the connection complies material of the the wire to the strands of the with the 4 mm banana lantern contact metal part. wire into. sockets of the spring meet the worldwide most need of low famous manufacturers. resistance and reliability. Fichier DataSheet TENMA 1060 . 17/10/2016. Indice A. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. 2016. Dimensions in millimeters. ACCESSIBLE. Able to be touched with a standard test finger or test pin. BASIC INSULATION. Insulation of HAZARDOUS LIVE parts which provides basic protection. CAT II. Measurement or overvoltage category II. For measurement per- formed on / equipment connected to the building wiring. CAT III. Measurement or overvoltage category III. For measurement performed on / equipment connected to part of a building wiring installation. CAT IV. Measurement or overvoltage category IV. For measurement performed on / equipment connected to the origin of the electrical supply to a building. CLEARANCE. Shortest distance in air between two conductive parts. CREEPAGE DISTANCE. Shortest distance along the surface of a solid insulating material between two conductive parts. CTI. Comparative Tracking Index of the insulating material in accordance with IEC 60112. DOUBLE INSULATION. Insulation comprising both BASIC INSULATION and SUPPLEMENTARY INSULATION. Very low voltages only : EN / IEC 60529:2001. The 2001 version of the European / international 33 V AC / 70 V DC, standard regarding the degrees of protection provided by enclosures. 36 A (at +40 C). EN / IEC 61010-1:2010. The latest version (in February 2012) of the European / international standard regarding the safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements. Version year 2010. -20 C mini., +80 C maxi. (please see above too). EN / IEC 61010-031:2008. The latest version (in February 2012) of the European / international standard regarding the safety requirements for European DirectiveRoH 2011/65/EU. electrical equipment for measurement, control and laboratory use Part 031: Safety requirements for hand-held probe assemblies for electrical measure- European REACH regulation n1907 / 2006. ment and test. Version year 2008. LV. European Directive 2006/95/EC on the harmonisation of the laws of RoH compliant, Pb 4 % in conductor, Pb 0.1 % in insulator, Hg 0.1 %, Cr VI 0.1 %, Member States relating to electrical equipment designed for use within Cd 0.01 %, PBB 0.1 %, and PBDE 0.1 %. certain voltage limits. (Usually called the Low Voltage Directive.) REACH compliant, no substances from the candidate list of SVHC for authorisation at mass MAINS. Low-voltage electricity supply system to which the equipment concerned is designed to be connected for the purpose of powering the concentrations greater than 0.1 %. equipment. Conductors : nickel-coated brass and brass. MAINS CIRCUIT. Circuit which is intended to be directly connected to the MAINS for the purpose of powering the equipment. Insulators and lantern contact spring, please contact us OVERVOLTAGE CATEGORY. Numeral defining a TRANSIENT OVER- VOLTAGE condition. Black Red POLLUTION. Addition of foreign matter, solid, liquid or gaseous (ionized gases), that may produce a reduction of dielectric strength or surface 0.005 kg. resistivity. POLLUTION DEGREE. Numeral indicating the level of POLLUTION that Designed and manufactured in France. may be present in the environment. POLLUTION DEGREE 1. No POLLUTION or only dry, non-conductive Year of 1st placing on the market 1993. POLLUTION occurs, which has no influence. POLLUTION DEGREE 2. Only non-conductive POLLUTION occurs except One piece per bag (in one bag : 1 metal part including 1 screw + 1 plastic part). that occasionally a temporary conductivity caused by condensation is expected. REINFORCED INSULATION. Insulation which provides protection against electric shock not less than that provided by DOUBLE INSULATION. RoH. European Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment. SOLID INSULATION. Insulating materials. SUPPLEMENTARY INSULATION. Independent insulation applied in addition to BASIC INSULATION in order to provide protection against electric shock in the event of a failure of BASIC INSULATION. TRANSIENT OVERVOLTAGE. Short duration overvoltage of a few milliseconds or less, oscillatory or non-oscillatory, usually highly damped. WORKING VOLTAGE. Highest r.m.s. value of the a.c. or d.c. voltage across any particular insulation which can occur when the equipment is supplied at rated voltage. Fichier DataSheet TENMA 1060 . 17/10/2016. Indice A. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. 2016. Dimensions in millimeters.