DC/DC Railway Converter TEN 10WIRH Series, 10 Watt Fully encapsulated DIP-24 package 3000 VAC I/O isolation (reinforced) 4:1 input voltage range: 36 160 VDC EN 50155 and EN 61373 certified Internal class A EMI filter UL 62368-1 IEC 62368-1 -40C up to +75C without derating The TEN 10WIRH is a series of 10 watt railway-certified DC/DC converters with EN 45545-2 fire behavior reinforced I/O isolation for highest reliability in harsh environments. The proven Remote on/off function and certified design guarantees highest resistance against thermal shocks, moisture, mechanical shocks, and vibration. The TEN 10WIRH comes with ad- Undervoltage lockout (UVLO), ditional EN 62368-1 safety approvals for IT equipment and EN 45545-2 certifi- short-circuit protection (SCP), cation for fire behavior. Thanks to its favorable operating temperature range of overtemperature protection (OTP), and -40C to +75C without derating (depending on the model), the TEN 10WIRH overvoltage protection (OVP) presents a first choice for demanding applications. 3-year product warranty Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TEN 10-11010WIRH 3.3 VDC 2 500 mA 83 % TEN 10-11011WIRH 5.1 VDC 2 000 mA 87 % TEN 10-11012WIRH 12 VDC 830 mA 88 % TEN 10-11013WIRH 36 - 160 VDC 15 VDC 670 mA 88 % (110 VDC nom.) TEN 10-11015WIRH 24 VDC 416 mA 88 % TEN 10-11021WIRH +5 VDC 1 000 mA 5 VDC 1 000 mA 84 % TEN 10-11022WIRH +12 VDC 416 mA 12 VDC 416 mA 87 % TEN 10-11023WIRH +15 VDC 333 mA 15 VDC 333 mA 87 % Options on demand (backorder with MOQ - Optional models with adjustable output voltage non stocking item) Page 1 / 5 www.tracopower.com January 6, 2022TEN 10WIRH Series, 10 Watt Input Specifications Input Current - At no load 6 mA typ. Surge Voltage 200 VDC max. (1 s max.) Input Inrush Current 35 A typ. Under Voltage Lockout 32 VDC min. / 34 VDC typ. / 35.8 VDC max. Recommended Input Fuse 630 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Pi-Type Output Specifications Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.2% max. dual output models: 0.5% max. - Load Variation (0 - 100%) single output models: 0.2% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) - Voltage Balance dual output models: 2% max. (symmetrical load) - Cross Regulation dual output models: 5% max. (25% / 100% asym. load) Ripple and Noise - single output 3.3 Vout models: 50 mVp-p typ. (w/ 10F) (20 MHz Bandwidth) 5.1 Vout models: 50 mVp-p typ. (w/ 10F) 12 Vout models: 75 mVp-p typ. (w/ 10F) 15 Vout models: 75 mVp-p typ. (w/ 10F) 24 Vout models: 75 mVp-p typ. (w/ 4.7F) - dual output 5 / -5 Vout models: 75 / 75 mVp-p typ. (w/ 10F) 12 / -12 Vout models: 75 / 75 mVp-p typ. (w/ 10F) 15 / -15 Vout models: 75 / 75 mVp-p typ. (w/ 10F) Capacitive Load - single output 3.3 Vout models: 3 000 F max. 5.1 Vout models: 2 500 F max. 12 Vout models: 430 F max. 15 Vout models: 350 F max. 24 Vout models: 125 F max. - dual output 5 / -5 Vout models: 1 440 / 1 440 F max. 12 / -12 Vout models: 250 / 250 F max. 15 / -15 Vout models: 180 / 180 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Start-up Time 30 ms typ. / 60 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 150% typ. of Iout max. Overvoltage Protection 112 - 151% of Vout nom. (depending on model) 3.7 - 5 VDC (3.3 VDC model) 5.6 - 7 VDC (5 VDC model) 13.5 - 16 VDC (12 VDC model) 18.3 - 22 VDC (15 VDC model) 29.1 - 34.5 VDC (24 VDC model) 5.6 - 7 VDC (5 VDC model) 13.5 - 18.2 VDC (12 VDC model) 17 - 22 VDC (15 VDC model) Transient Response - Peak Variation 320 mV typ. / 400 mV max. (75% to 100% Load Step) - Response Time 250 s typ. / 300 s max. (75% to 100% Load Step) All specifications valid at nominal voltage, resistive full load and +25C after warm-up time, unless otherwise stated. Page 2 / 5 www.tracopower.com January 6, 2022