DC/DC Converter TEN 6WIN Series, 6 Watt Wide 4:1 input voltage range High efficiency Operating temperature range 40C to +85C Models with 1500 VDC and 3000 VDC I/O isolation (functional insulation) UL 62368-1 IEC 62368-1 Input filter meets EN 55022, class A The TEN 6WIN series is designed for an optimized cost/performance ratio of Overload protection DC/DC converters with output power of 6 Watt. General features like no minimum load requirement, overload protection, inter- DIP-24 plastic package nal filter for EN55022 class A and high efficiency make these converters easy Industry standard pinout to design in. With the popular DIP-24 standard package they are also a drop in replacement for many cost critical applications. 3-year product warranty Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TEN 6-2410WIN 3.3 VDC 1 200 mA 77 % TEN 6-2411WIN 5 VDC 1 200 mA 80 % TEN 6-2412WIN 12 VDC 500 mA 84 % TEN 6-2413WIN 9 - 36 VDC 15 VDC 400 mA 84 % (24 VDC nom.) TEN 6-2415WIN 24 VDC 250 mA 84 % TEN 6-2421WIN +5 VDC 500 mA 5 VDC 500 mA 80 % TEN 6-2422WIN +12 VDC 250 mA 12 VDC 250 mA 84 % TEN 6-2423WIN +15 VDC 200 mA 15 VDC 200 mA 84 % TEN 6-4810WIN 3.3 VDC 1 200 mA 77 % TEN 6-4811WIN 5 VDC 1 200 mA 80 % TEN 6-4812WIN 12 VDC 500 mA 84 % TEN 6-4813WIN 18 - 75 VDC 15 VDC 400 mA 84 % (48 VDC nom.) TEN 6-4815WIN 24 VDC 250 mA 84 % TEN 6-4821WIN +5 VDC 500 mA 5 VDC 500 mA 80 % TEN 6-4822WIN +12 VDC 250 mA 12 VDC 250 mA 84 % TEN 6-4823WIN +15 VDC 200 mA 15 VDC 200 mA 84 % Options Suffix -HI - Models with high isolation (3000 VDC) Page 1 / 4 www.tracopower.com December 16, 2021TEN 6WIN Series, 6 Watt Input Specifications Input Current - At no load 24 Vin models: 20 mA typ. 48 Vin models: 10 mA typ. - At full load 24 Vin models: 215 mA max. (3.3 Vout model) 300 mA max. (5 Vout model) 300 mA max. (12 Vout model) 300 mA max. (15 Vout model) 300 mA max. (24 Vout model) 260 mA max. (5 / -5 Vout model) 300 mA max. (12 / -12 Vout model) 300 mA max. (15 / -15 Vout model) 48 Vin models: 110 mA max. (3.3 Vout model) 150 mA max. (5 Vout model) 150 mA max. (12 Vout model) 150 mA max. (15 Vout model) 150 mA max. (24 Vout model) 130 mA max. (5 / -5 Vout model) 150 mA max. (12 / -12 Vout model) 150 mA max. (15 / -15 Vout model) Surge Voltage 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) Start-up Voltage 24 Vin models: 7 VDC min. / 8 VDC typ. / 9 VDC max. 48 Vin models: 14 VDC min. / 16 VDC typ. / 18 VDC max. Under Voltage Lockout 8.5 VDC max. 24 Vin models: 48 Vin models: 16 VDC max. Reflected Ripple Current 24 Vin models: 20 mA typ. 48 Vin models: 15 mA typ. Recommended Input Fuse 24 Vin models: 1 500 mA (slow blow) 48 Vin models: 800 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Pi-Type Short Circuit Input Power 3 W max. Output Specifications Voltage Set Accuracy 2% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.5% max. dual output models: 0.5% max. - Load Variation (0 - 100%) single output models: 1.2% max. dual output models: 1.2% max. (Output 1) 1.2% max. (Output 2) - Voltage Balance dual output models: 2% max. (symmetrical load) Ripple and Noise - 20 MHz Bandwidth 80 mVp-p max. Capacitive Load - single output 3.3 Vout models: 470 F max. 5 Vout models: 470 F max. 12 Vout models: 100 F max. 15 Vout models: 100 F max. 24 Vout models: 47 F max. - dual output 5 / -5 Vout models: 100 / 100 F max. 12 / -12 Vout models: 100 / 100 F max. 15 / -15 Vout models: 100 / 100 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Short Circuit Protection Continuous, Automatic recovery Overload Protection Foldback Mode All specifications valid at nominal voltage, resistive full load and +25C after warm-up time, unless otherwise stated. Page 2 / 4 www.tracopower.com December 16, 2021