DC/DC Converter THR 10WI Series, 10 Watt Reinforced I/O-isolation 3000 VAC Shock and vibration resistance according to EN 61373 Wide 4:1 input voltage range: 9-36, 18-75, 40-160 VDC Operating temperature range -40 to +90C UL 62368-1 IEC 62368-1 Internal EN 55032 class A filter The THR 10WI is 10 Watt DC/DC converters series with reinforced isolation (3000 VAC). These regulated DC/DC converters come in either a 2 x1 pack- High efficiency up to 89% age and also feature increased resistance against shock and vibration accord- ing to EN 61373. The THR 3WI offers an internal input filter to comply with EN Protection against overload, overvoltage 55032 class A. High efficiencies up to 89% allow safe operation from 40C to and short circuit +90C (with derating). All models have a wide 4:1 input voltage range and pre- 3-year product warranty cisely regulated, isolated output voltages. With the latest IT safety certifications (IEC/EN/UL 62368-1) the THR 10WI series is the perfect choice for many de- manding applications in the industrial, transportation and instrumentation sec- tors. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. THR 10-2411WI 5 VDC 2 000 mA 84 % THR 10-2412WI 12 VDC 835 mA 86 % THR 10-2413WI 9 - 36 VDC 15 VDC 670 mA 87 % (24 VDC nom.) THR 10-2415WI 24 VDC 417 mA 88 % THR 10-2422WI +12 VDC 417 mA 12 VDC 417 mA 86 % THR 10-2423WI +15 VDC 335 mA 15 VDC 335 mA 87 % THR 10-4811WI 5 VDC 2 000 mA 85 % THR 10-4812WI 12 VDC 835 mA 87 % 18 - 75 VDC THR 10-4813WI 15 VDC 670 mA 87 % (48 VDC nom.) THR 10-4815WI 24 VDC 417 mA 86 % THR 10-4822WI +12 VDC 417 mA 12 VDC 417 mA 89 % THR 10-4823WI +15 VDC 335 mA 15 VDC 335 mA 88 % THR 10-7211WI 5 VDC 2 000 mA 82 % THR 10-7212WI 12 VDC 835 mA 85 % THR 10-7213WI 40 - 160 VDC 15 VDC 670 mA 85 % (110 VDC nom.) THR 10-7215WI 24 VDC 417 mA 85 % THR 10-7222WI +12 VDC 417 mA 12 VDC 417 mA 86 % THR 10-7223WI +15 VDC 335 mA 15 VDC 335 mA 86 % Options on demand - Optional models with alternative pinning (backorder with MOQ - Optional models with heatsink non stocking item) Page 1 / 5 www.tracopower.com July 21, 2021THR 10WI Series, 10 Watt Input Specifications Input Current - At no load 24 Vin models: 25 mA typ. 48 Vin models: 15 mA typ. 110 Vin models: 10 mA typ. - At full load 24 Vin models: 484 mA typ. 48 Vin models: 240 mA typ. 110 Vin models: 107 mA typ. Surge Voltage 24 Vin models: 50 VDC max. (100 ms max.) 48 Vin models: 100 VDC max. (100 ms max.) 110 Vin models: 170 VDC max. (100 ms max.) Under Voltage Lockout 24 Vin models: 7.5 VDC typ. 48 Vin models: 16 VDC typ. 110 Vin models: 37 VDC typ. Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Pi-Type Output Specifications Output Voltage Adjustment 10% (single output models only) (By external trim resistor) See application note: www.tracopower.com/overview/thr10wi Output power must not exceed rated power Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.2% max. dual output models: 0.2% max. - Load Variation (0 - 100%) single output models: 0.5% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) - Voltage Balance dual output models: 2% max. (symmetrical load) Ripple and Noise - single output 5 Vout models: 50 mVp-p typ. (w/ 10 F, 25 V MLCC) (20 MHz Bandwidth) 12 Vout models: 100 mVp-p typ. (w/ 10 F, 25 V MLCC) 15 Vout models: 100 mVp-p typ. (w/ 10 F, 25 V MLCC) 24 Vout models: 150 mVp-p typ. (w/ 4.7 F, 50 V MLCC) - dual output 12 / -12 Vout models: 100 / 100 mVp-p typ. (w/ 10 F, 25 V MLCC) 15 / -15 Vout models: 100 / 100 mVp-p typ. (w/ 10 F, 25 V MLCC) Capacitive Load - single output 5 Vout models: 2 200 F max. 12 Vout models: 330 F max. 15 Vout models: 220 F max. 24 Vout models: 100 F max. - dual output 12 / -12 Vout models: 150 / 150 F max. 15 / -15 Vout models: 100 / 100 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Start-up Time 50 ms typ. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 150% typ. of Iout max. Overvoltage Protection 125% typ. of Vout nom. Transient Response - Response Deviation 3% typ. / 5% max. (75% to 100% Load Step) - Response Time 300 s max. (75% to 100% Load Step) Safety Specifications Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 www.tracopower.com/overview/thr10wi - Certification Documents All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 5 www.tracopower.com July 21, 2021