AC/DC Industrial Power Supply TIB 120 Series, 120 Watt Slim profile, for DIN-rail mounting Alternative side-mounting for flat panels High power factor by active power correction Very high efficiency up to 94% Back power immunity 150% peak current for 4 s Operating temperature range: 40C to +70C max. Adjustable output voltage Short circuit and overload protection 3 year product warranty UL 508 UL 60950-1 IEC 60950-1 This generation of DIN-rail power supplies combines the most efficient circuit topology with optimized cost/performance ratio for industrial environments and for electrical control cabinets. They have a very high efficiency of up to 94.0% which allows a very slim package design. The output voltage is adjustable from 2% to +17%. The case offers the potentially useful feature to fix the DIN-rail clip to the side wall for the mounting inside flat panels. Over a period of mini- mum 4 seconds they can operate with a boost power of 150%. The boost pow- er facilitates the activation of stepper motors, solenoids or actuators. The units operate with a high power factor of up to 97% by active power factor correc- tion which also keeps the input inrush current low. The TIB series are also avail- able with other nominal power of 80, 240 or 480 Watt (+50% boost power). They come with the safety standard approvals for IEC/EN 60950-1, UL 60950-1 and UL 508. Models Order Code Output Power Output Voltage Output Current Output Current Efficiency max. nom. (adjustable) max. peak typ. TIB 120-112 12 VDC (11.8 - 15.0 VDC) 10 000 mA 15 000 mA 94 % TIB 120-124 120 W 24 VDC (23.5 - 28.0 VDC) 5 000 mA 7 500 mA 94 % TIB 120-148 48 VDC (47.0 - 56.0 VDC) 2 500 mA 3 750 mA 94 % Page 1 / 6 www.tracopower.com April 9, 2019TIB 120 Series, 120 Watt Input Specifications Input Voltage 85 - 264 VAC (Full Range) Input Frequency 45 - 65 Hz Power Consumption - at no Load 2 200 mW typ. Input Inrush Current - at 230 VAC 30 A max. - at 115 VAC 15 A max. Power Factor - at 230 VAC 0.8 min. (Active Power Factor Correction) - at 115 VAC 0.97 min. (Active Power Factor Correction) Output Specifications Output Voltage Adjustment 12 VDC model: 11.8 - 15.0 VDC 24 VDC model: 23.5 - 28.0 VDC 48 VDC model: 47.0 - 56.0 VDC By trim potentiometer Output power must no exceed rated power Regulation - Input Variation (Vmin - Vmax) 0.1% max. 0.5% max. - Load Variation (10 - 90%) Output Current peak Peak Power: 105 - 150% of Iout max. Peak Operation Time: 4 s max. (switch off) Off Time: 10 s typ. In peak power mode, the unit continuously switches off the output voltage after 4 s and restarts after approx. 10 s. Ripple and Noise 12 VDC model: 100 mVp-p max. (20 MHz Bandwidth) 24 VDC model: 100 mVp-p max. 48 VDC model: 200 mVp-p max. Capacitive Load Infinite Minimum Load not required Temperature Coefficient 0.02 %/K max. Hold-up Time - at 230 VAC 20 ms min. - at 115 VAC 20 ms min. Start-up Time - at 230 VAC 2 000 ms max. - at 115 VAC 2 000 ms max. Overload Protection CC-Mode Output Current Limitation 155% min. of Iout max. Short Circuit Protection Switch off after 4 s delay, automatic restart Overvoltage Protection 117 - 158% of Vout nom. (depending on model) 16 - 19 VDC (12 VDC model) 32 - 35 VDC (24 VDC model) 56 - 60 VDC (48 VDC model) (In case of an internal error a second voltage reg- ulation loop keeps the output voltage at a save level, the power supply turnes off and tries to restart after 10 s.) Transient Response - Peak Variation 800 mV max. (10% to 90% Load Step) - Response Time 2000 s typ. (10% to 90% Load Step) Safety Specifications Safety Standards - IT / Multimedia Equipment IEC 60950-1 EN 60950-1 UL 60950-1 CSA-C22.2, 60950-1-07 - Industrial Control Equipment UL 508 www.tracopower.com/overview/tib120 - Certification Documents Protection Class Class I Prepared: Connection to PE All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 6 www.tracopower.com April 9, 2019