AC/DC Industrial Power Supply TIB 240-EX Series, 240 Watt UL Hazloc Class I, division 2 approval and ATEX certification SEMI F47 compliant for voltage sag immunity Rugged metal case with optional side-mounting Back power immunity 150% peak current for 4 s Operating Temp 40C to +70C (full load up to 60C) Adjustable output voltage High Reliability: MTBF 1 mill hrs per IEC 61709 UL 508 UL 60950-1 IEC 60950-1 Short circuit and overload protection The TIB 240-EX family of next generation of 240 Watt din rail power supplies feature high efficiency operation of up to 95% enabling a slim design with al- 5 year product warranty ternative side-mounting for flat panels (DC OK Indicator on both front and side panel). These products certified to UL Hazloc Class 1 / Div 2, and ATEX (EN 60079-0, EN 60079-7. EN 600079-15) for operation in hazardous locations. These convection cooled power supplies have a -40C to +60C full load oper- ating temperature range. 150% peak power for up to 4 seconds which is ideal for stepper motors, solenoids or actuators. The TIB 240-EX series has an im- portant Back Power Immunity feature that helps protect against shut-down or malfunction with loads such as inductors and decelerating motors that can feed voltage back to the power supply. Outputs are radio-interference-suppressed to impede radiation at long output lines which reduces the common mode current to within limits of telecommunication ports. The series operate with a high pow- er factor of up to 99% which also minimizes inrush current. Additional qualifi- cations include IEC/EN/UL 60950-1, UL 508 and CB Report with EMC compli- ance to IEC/EN 61000-6-2 and IEC/EN 61000-6-3. Models Order Code Output Power Output Voltage Output Current Output Current Efficiency max. nom. (adjustable) max. peak typ. TIB 240-124EX 24 VDC (23.5 - 28.0 VDC) 10 000 mA 15 000 mA 95 % 240 W TIB 240-148EX 48 VDC (47.0 - 56.0 VDC) 5 000 mA 7 500 mA 95 % Page 1 / 6 www.tracopower.com April 9, 2019TIB 240-EX Series, 240 Watt Input Specifications Input Voltage 85 - 264 VAC (Full Range) Input Frequency 45 - 65 Hz Power Consumption - at no Load 2 300 mW typ. Input Inrush Current - at 230 VAC 30 A max. - at 115 VAC 15 A max. Power Factor - at 230 VAC 0.92 min. (Active Power Factor Correction) - at 115 VAC 0.98 min. (Active Power Factor Correction) Output Specifications Output Voltage Adjustment 24 VDC model: 23.5 - 28.0 VDC 48 VDC model: 47.0 - 56.0 VDC By trim potentiometer Output power must no exceed rated power Regulation - Input Variation (Vmin - Vmax) 0.1% max. - Load Variation (10 - 90%) 0.5% max. Output Current peak Peak Power: 105 - 150% of Iout max. Peak Operation Time: 4 s max. (switch off) Off Time: 10 s typ. In peak power mode, the unit continuously switches off the output voltage after 4 s and restarts after approx. 10 s. Ripple and Noise 24 VDC model: 100 mVp-p max. (20 MHz Bandwidth) 48 VDC model: 200 mVp-p max. Capacitive Load Infinite Minimum Load not required Temperature Coefficient 0.02 %/K max. Hold-up Time - at 230 VAC 20 ms min. - at 115 VAC 20 ms min. Start-up Time - at 230 VAC 2 000 ms max. - at 115 VAC 2 000 ms max. Overload Protection CC-Mode Output Current Limitation 155% min. of Iout max. Short Circuit Protection Switch off after 4 s delay, automatic restart Overvoltage Protection 117 - 146% of Vout nom. (depending on model) 32 - 35 VDC (24 VDC model) 56 - 60 VDC (48 VDC model) (In case of an internal error a second voltage reg- ulation loop keeps the output voltage at a save level, the power supply turnes off and tries to restart after 10 s.) Transient Response - Peak Variation 600 mV max. (10% to 90% Load Step) - Response Time 2000 s typ. (10% to 90% Load Step) All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 6 www.tracopower.com April 9, 2019