AC/DC Power Supplies TOP 60 Series, 60 Watt CB Scheme Features 60 W power supply in 2.0x 4.0 footprint Single-, dual- and triple output models Highest efcfi iency of 88% typ. Operating temperature range 10C to +70C EMI filter meets EN 55022, level B Compliance with EN 61000-3-2 3-year product warranty The new TOP-60 series AC/DC open frame power supplies with Industry standard 2.0 x 4.0 (50.8 x 101.6 mm) footprint feature single-, dual- and triple output models with up to 60 Watt continuous output power. The high efcfi iency alouds an operation up to 70C with convection cooling. Compliance with global safety and EMC standards qualify these power supplies for industrial and IT applications. Models 1) 1) Order Code Output Power Output 1 Output 2 Output 3 nominal TOP 60105 55 W 5.0 VDC / 11.0 A TOP 60112 60 W 12 VDC / 5.0 A TOP 60115 64 W 15 VDC / 4.3 A TOP 60124 64 W 24 VDC / 2.7 A TOP 60148 64 W 48 VDC / 1.35 A 1) TOP 60252 55 W +5.0 VDC / 6.0 A (8.0 A) +12 VDC / 3.0 A 1) TOP 60254 55 W +5.0 VDC / 6.0 A (8.0 A) +24 VDC / 1.5 A 1) 55 W +5.0 VDC / 6.0 A (8.0 A) +12 VDC / 3.0 A 12 VDC / 0.5 A TOP 60522 1) TOP 60533 55 W +5.0 VDC / 6.0 A (8.0 A) +15 VDC / 2.4 A 15 VDC / 0.5 A 1) TOP 60316 38 W +3.3 VDC / 6.0 A (8.0 A) +5.2 VDC / 3.0 A +12 VDC / 0.5 A 1) TOP 60317 38 W +5.0 VDC / 6.0 A (8.0 A) +3.3 VDC / 1.5 A +12 VDC / 0.5 A 1) TOP 60318 55 W +5.0 VDC / 6.0 A (8.0 A) +24 VDC / 1.5 A 12 VDC / 0.5 A 1) Pe ak cur rent fo r m a x. 10 s e c. o r wit h fo rce d air co o ling Total power should not exceed nominal power AC/DC Power Supplies TOP-60 Series 60 Watt Input Specifications Input voltage nominal 100 240 VAC (universal input) AC input range 90 264 VAC (with derating at low input) DC input range 110 370 VDC (max. 40 W output power at input below 120 VDC) Input frequency 47 63 Hz Harmonic limits EN 61000-3-2, class A Earth leakage current 150 A max. 264 VAC, 63 Hz Inrush current 115 VAC 30 A typ. (< 2ms, cold start at 25C) 230 VAC 60 A typ. Input protection T3.15 A internal fuses (line and neutral) Recommended circuit breaker 5 A (characteristic C or slow blow fuse) Output Specifications Voltage set accuracy single output models: 2 % max. multi output models, output 1: 3 % max. multi output models, other outputs: 5 % max. Regulation Input 0.5 % max. Load variation single output models: 2 % max. multi output models, output 1: 3 % max. multi output models, other outputs: 5 % max. Minimum load (to meet regulation specs) multi output models, output 1: 0.5 A multi output models, output 2: 0.1 A (not required for single output models and output 3 of multi output models) Ripple and noise (20Mhz Bandwidth) 3.3 & 5 VDC models: <100 mVp-p other models: 1 % Vout Overvoltage protection (output 1 only) at 110 % 135 % of Vout nominal Short circuit protection foldback (automatic recovery) Capacitive load TOP 60105/60112/60115/60124/60148 models: 3300/2200/1500/470/0 F max. TOP 60252/60254 models: 2200/82 F max. TOP 60522/60316/60317/60533/60318 models: 1500/5600/1200/470/330 F max. Transient response (25 % load step change) 500 s typ. Hold-up time Vin = 110 VAC 12 ms typ. Vin = 230 VAC 15 ms typ. General Specifications Temperature ranges Operating 10C to +70C Storage (non-operating) 40C to +85C Power derating 2.5 %/K above +50C Humidity (non condensing) 0 95 % rel. H max. Efficiency 80 88 % 75 % for TOP 60316 & TOP 60317 Switching frequency 62 kHz typ. (pulse width modulation) Altitude during operation up to 3000 m (10000 ft) approved Start-up time Vin = 115 VAC <3.5s Vin = 230 VAC <2s Electromagnetic compatibility Electrostatic discharge ESD EN 61000-4-2 8 kV / 6 kV RF field susceptibility EN 61000-4-3 3 V/m Electrical fast transient / burst immunity input EN 61000-4-4 2 kV Electrical fast transient / burst immunity output EN 61000-4-4 2 kV Surge immunity line neutral ground EN 61000-4-5, 2 kV Surge immunity output EN 61000-4-5 1 kV Immunity to conducted RF disturbances EN 61000-4-6 3 Vrms Magnetic field immunity EN 61000-4-8 3 A/m Mains voltage dips and interruptions EN 61000-4-11 30 % 500 ms, 60 % 100 ms, >95 % 10 ms