AC/DC Industrial Power Supply TPI 100A Series, 100 Watt Highest power density 100 W open frame power supply in 2 x 3 package I/O reinforced isolation 3000 VDC Ready to meet ErP directive, < 0.3 W no load power consumption Highest efficiency 91% - 92% across 10% - 100% load range Active power factor correction > 95 Protection class II prepared Operating up to 5000 m altitude Adjustable output voltage UL 62368-1 IEC 62368-1 3-year product warranty The TPI 100A Series of 100 Watt AC/DC power supplies features a 3000 VAC I/O reinforced isolation. Excellent efficiency of up to 92% allows a high power density for the standard 2.0 x 3.0 packaging format. The full load operating temperature range is 40C to +50C while it goes up to 80C with load derat- ing. The power supplies are designed to meet the ErP directive (< 0.3 W no load power consumption). They come with an active power factor correction and the EMC characteristic is dedicated for applications in industrial and do- mestic fields. High reliability is provided by use of industrial quality grade com- ponents and an excellent thermal management. It makes the products an ideal solution for any demanding industrial devices and space critical applications. Models Order Code Output Power Output Voltage Output Current Efficiency max. nom. (adjustable) max. typ. TPI 100-112A-J 12 VDC (10.8 - 13.2 VDC) 8 340 mA 91 % TPI 100-115A-J 15 VDC (13.5 - 16.5 VDC) 6 670 mA 92 % TPI 100-124A-J 24 VDC (21.6 - 26.4 VDC) 4 170 mA 92 % 100 W TPI 100-128A-J 28 VDC (25.2 - 30.8 VDC) 3 580 mA 92 % TPI 100-136A-J 36 VDC (32.4 - 39.6 VDC) 2 780 mA 91 % TPI 100-148A-J 48 VDC (43.2 - 52.8 VDC) 2 090 mA 91 % Page 1 / 4 www.tracopower.com December 18, 2020TPI 100A Series, 100 Watt Input Specifications Input Voltage - AC Range 85 - 264 VAC (Full Range) - DC Range 120 - 370 VDC (Designed for, no certification) Input Frequency 47 - 63 Hz Input Current - Full Load & Vin = 230 VAC 550 mA max. - Full Load & Vin = 115 VAC 1 150 mA max. Power Consumption - At no load 300 mW max. (Ready to meet ErP directive) Input Inrush Current - At 230 VAC 100 A max. Power Factor - At 230 VAC 0.95 min. - At 115 VAC 0.95 min. Input Protection T 3.15 A / 250 VAC (Internal Fuse in L & N) Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Output Specifications Output Voltage Adjustment 10% (By trim potentiometer) Output power must not exceed rated power Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) 0.2% max. - Load Variation (0 - 100%) 0.5% max. Ripple and Noise 12 VDC model: 120 mVp-p typ. (w/ 10 F X7R) (20 MHz Bandwidth) 15 VDC model: 150 mVp-p typ. (w/ 10 F X7R) 24 VDC model: 160 mVp-p typ. (w/ 1 F X7R) 28 VDC model: 180 mVp-p typ. (w/ 1 F X7R) 36 VDC model: 190 mVp-p typ. (w/ 1 F X7R) 48 VDC model: 340 mVp-p typ. (w/ 0.1 F X7R) Capacitive Load 12 VDC model: 6 950 F max. 15 VDC model: 4 450 F max. 24 VDC model: 1 750 F max. 28 VDC model: 1 280 F max. 36 VDC model: 770 F max. 48 VDC model: 430 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Hold-up Time - At 230 VAC 22 ms min. - At 115 VAC 22 ms min. Start-up Time - At 230 VAC 1 000 ms max. - At 115 VAC 1 000 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 115 - 150% of Iout max. Overvoltage Protection 115 - 135% of Vout nom. Transient Response - Response Deviation 3% max. (50% to 75% Load Step) - Response Time 500 s typ. (50% to 75% Load Step) Safety Specifications Safety Standards - IT / Multimedia Equipment EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 www.tracopower.com/overview/tpi100a - Certification Documents Protection Class Class I & II (Prepared): Reinforced Insulation Pollution Degree PD 2 Over Voltage Category OVC II All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 4 www.tracopower.com December 18, 2020