AC/DC Medical Power Supply TPP 100 Series, 100 Watt Encased 100 W power supply with screw connection in 2.44 x 3.6 package Certification according to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP Low leakage current <75 A rated for BF applications Risk management process according to ISO 14971 incl. risk management file Acceptance criteria for electronic assemblies acc. to IPC-A-610 Level 3 Active power factor correction >0.95 Protection class l and ll prepared ES 60601-1 IEC 60601-1 Operating up to 5000 m altitude UL 62368-1 IEC 62368-1 Ready to meet ErP directive, <0.3 W no The TPP 100 Series of 100 Watt AC/DC encased power supplies feature a re- load power consumption inforced double I/O isolation system according to latest medical safety stan- dards (60601-1 3rd edition, 2 x MOPP). The earth leakage current is below 75 5-year product warranty A which makes the units suitable for BF (body floating) applications. The ex- cellent efficiency of up to 92% allows a high power density for the standard 2.44 x 3.6 packaging format. The full load operating temperature range is 25C to +60C while it goes up to 80C with 50% load derating. The EMC characteristic is dedicated for applications in industrial and medical fields. High reliability is provided by the use of industrial quality grade components and an excellent thermal management. It makes the products an ideal solution for medical devices and for demanding safety and space critical applications. Models Order Code Output Power Output Voltage Output Current Efficiency max. nom. (adjustable) max. typ. TPP 100-112 12 VDC (10.8 - 13.2 VDC) 8 340 mA 91 % TPP 100-115 15 VDC (13.5 - 16.5 VDC) 6 670 mA 92 % TPP 100-124 24 VDC (21.6 - 26.4 VDC) 4 170 mA 92 % 100 W 28 VDC (25.2 - 30.8 VDC) 3 580 mA 92 % TPP 100-128 TPP 100-136 36 VDC (32.4 - 39.6 VDC) 2 780 mA 91 % TPP 100-148 48 VDC (43.2 - 52.8 VDC) 2 090 mA 91 % Page 1 / 4 www.tracopower.com December 18, 2020TPP 100 Series, 100 Watt Input Specifications Input Voltage - AC Range 85 - 264 VAC (Full Range) - DC Range 120 - 370 VDC (Designed for, no certification) Input Frequency 47 - 63 Hz Input Current - Full Load & Vin = 230 VAC 550 mA max. - Full Load & Vin = 115 VAC 1 150 mA max. Power Consumption - At no load 300 mW max. (Ready to meet ErP directive) Input Inrush Current - At 230 VAC 60 A max. Power Factor - At 230 VAC 0.95 min. (Active Power Factor Correction) - At 115 VAC 0.95 min. (Active Power Factor Correction) Input Protection T 3.15 A / 250 VAC (Internal Fuse in L & N) Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Output Specifications Output Voltage Adjustment 10% (By trim potentiometer) Output power must not exceed rated power Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) 0.2% max. - Load Variation (0 - 100%) 0.5% max. Ripple and Noise 12 VDC model: 120 mVp-p typ. (w/ 10 F X7R) (20 MHz Bandwidth) 15 VDC model: 150 mVp-p typ. (w/ 10 F X7R) 24 VDC model: 160 mVp-p typ. (w/ 1 F X7R) 28 VDC model: 180 mVp-p typ. (w/ 1 F X7R) 36 VDC model: 190 mVp-p typ. (w/ 1 F X7R) 48 VDC model: 340 mVp-p typ. (w/ 0.1 F X7R) Capacitive Load 12 VDC model: 6 950 F max. 15 VDC model: 4 450 F max. 24 VDC model: 1 750 F max. 28 VDC model: 1 280 F max. 36 VDC model: 770 F max. 48 VDC model: 430 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Hold-up Time - At 230 VAC 16 ms min. - At 115 VAC 16 ms min. Start-up Time - At 230 VAC 1 000 ms max. - At 115 VAC 1 000 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 115 - 150% of Iout max. Overvoltage Protection 115 - 135% of Vout nom. Transient Response - Response Deviation 3% max. (50% to 75% Load Step) - Response Time 500 s typ. (50% to 75% Load Step) All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 4 www.tracopower.com December 18, 2020