AC/DC Medical Power Supply TPP 180A-M Series, 180 Watt High power-density: 180 Watt in 3x2 package (open frame) I/O isolation 3000 VAC rated for 250 VAC working voltage Certification according to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP Risk management process according to ISO 14971 incl. risk management file Acceptance criteria for electronic assemblies acc. to IPC-A-610 Level 3 Peak power operation up to 220 Watt for 5s ES 60601-1 IEC 60601-1 Operating temperature 40C to 85C UL 62368-1 IEC 62368-1 Active power factor correction >0.9 The TPP 180A-M is series of encapsulated AC/DC power supplies coming in an open frame package. They feature a reinforced double I/O isolation (3000 Operating up to 5000m altitude VAC) system according to latest medical safety standards (60601-1 3rd edition, 5-year product warranty 2 x MOPP). The leakage current is below 300 A and makes the units suitable for BF (body floating) applications. The excellent efficiency of up to 94% allows a high power-density and compact design (3 x 2). The operating temperature range is 40C to +85C with derating above 50C. In natural convection oper- ation these power supplies deliver 150 Watt going up to 180 Watt with forced air cooling. Additionally, they can deliver 220 Watt peak power for 5s. The EMC characteristic is dedicated for applications in industrial and medical fields. High reliability is provided by using high quality components and an excellent ther- mal management making the TPP 180A-M an ideal solution for industrial and medical devices and for demanding safety and space critical applications. Models Order Code Output Power Output Voltage Output Current max. Output Current max. Output Current Efficiency max. nom. (adjustable) (Forced air cooling) (Natural convection) peak typ. TPP 180-112A-M 12 VDC (11.0 - 13.0 VDC) 15 000 mA 12 500 mA 18 334 mA 92 % TPP 180-115A-M 15 VDC (13.8 - 16.2 VDC) 12 000 mA 10 000 mA 14 667 mA 92 % TPP 180-124A-M 24 VDC (22.1 - 25.9 VDC) 7 500 mA 6 250 mA 9 167 mA 94 % 180 W TPP 180-136A-M 36 VDC (33.1 - 38.9 VDC) 5 000 mA 4 170 mA 6 111 mA 93 % TPP 180-148A-M 48 VDC (44.2 - 51.8 VDC) 3 750 mA 3 130 mA 4 583 mA 93 % TPP 180-153A-M 53 VDC (48.8 - 57.2 VDC) 3 400 mA 2 830 mA 4 151 mA 93 % Options on demand - Optional model with 18 VDC / 10 000 mA (backorder with MOQ - Optional model with 28 VDC / 6 430 mA non stocking item) Page 1 / 5 www.tracopower.com December 16, 2021TPP 180A-M Series, 180 Watt Input Specifications Input Voltage - AC Range Operational Range: 85 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) - DC Range Operational Range: 120 - 370 VDC (Designed for, no certification) Polarity: +DC: L / DC: N Input Frequency 47 - 63 Hz Input Current - Full Load & Vin = 230 VAC 1 500 mA max. - Full Load & Vin = 115 VAC 2 550 mA max. Power Consumption - At no load 200 mW max. (Ready to meet ErP directive) - At no load 150 mW typ. (Ready to meet ErP directive) Input Inrush Current - At 230 VAC 100 A max. - At 115 VAC 50 A max. Power Factor - At 230 VAC 0.9 min. (Active Power Factor Correction) - At 115 VAC 0.9 min. (Active Power Factor Correction) Input Protection T 4 A / 250 VAC Recommended Input Fuse 4 000 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Output Specifications Output Voltage Adjustment 8% (By trim potentiometer) Output power must not exceed rated power Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) 0.2% max. - Load Variation (0 - 100%) 0.5% max. Boost Power Output Current peak: See model table Peak power time: 5 s max. Peak power duty cycle: 20% max. Average operation power: 99 W max. (at natural convection) Ripple and Noise 12 VDC model: 200 mVp-p max. (w/ 1 F) (20 MHz Bandwidth) 15 VDC model: 200 mVp-p max. (w/ 1 F) 18 VDC model: 220 mVp-p max. (w/ 1 F) 24 VDC model: 220 mVp-p max. (w/ 1 F) 28 VDC model: 220 mVp-p max. (w/ 1 F) 36 VDC model: 220 mVp-p max. (w/ 1 F) 48 VDC model: 350 mVp-p max. (w/ 0.1 F) 53 VDC model: 350 mVp-p max. (w/ 0.1 F) Capacitive Load 12 VDC model: 10 000 F max. 15 VDC model: 6 800 F max. 18 VDC model: 4 700 F max. 24 VDC model: 2 700 F max. 28 VDC model: 1 800 F max. 36 VDC model: 1 200 F max. 48 VDC model: 680 F max. 53 VDC model: 560 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Hold-up Time - At 230 VAC 10 ms min. - At 115 VAC 10 ms min. Start-up Time - At 230 VAC 1 500 ms max. - At 115 VAC 1 500 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 130 - 175% of Iout max. 150% typ. of Iout max. All specifications valid at nominal voltage, resistive full load and +25C after warm-up time, unless otherwise stated. Page 2 / 5 www.tracopower.com December 16, 2021