DC/DC Converter TRI 10 Series, 10 Watt Reinforced I/O-isolation 5000 VAC rated for 1000 VAC working voltage Ultra-high isolation peak voltage 9000 VDC (1s) Common Mode Transient Immunity (dv/dt) 15 kV/s Operating temperature range -40 to UL 62368-1 IEC 62368-1 +85C The new TRI 10 is a high isolation, regulated 10 Watt DC/DC converter series Low no-load power consumption 144 which comes in a compact DIP-24 package. The core characteristic of the TRI 288 mW 10 series is a sophisticated reinforced isolation system which is able to with- stand high test voltages (9000 VDC for 1s and 5000 VAC for 60s) and working Internal EN 55032 class A filter voltages (1000 VACrms). Complementing this isolation characteristic is a high Common Mode Transient Immunity of 15 kV/s. The new design allows to fully High efficiency up to 88% integrate an EN 55032 class A filter and greatly reduces the no-load power 2:1 input voltage range: 9-18, 18-36, consumption. High efficiencies up to 88% allow safe operation from 40C to 36-75 VDC +65C without derating and up to +85C with derating. All models have a wide 2:1 input voltage range and precisely regulated, isolated output voltages. With Protection against overload, overvoltage the latest IT safety certifications (IEC/EN/UL 62368-1) the TRI 10 series is the and short circuit perfect choice for many demanding applications in the industrial, transportation 3-year product warranty and instrumentation sectors. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TRI 10-1210 3.3 VDC 2 700 mA 81 % TRI 10-1211 5.1 VDC 2 000 mA 83 % TRI 10-1212 12 VDC 833 mA 86 % 9 - 18 VDC TRI 10-1213 15 VDC 666 mA 88 % (12 VDC nom.) TRI 10-1215 24 VDC 416 mA 88 % TRI 10-1222 +12 VDC 416 mA 12 VDC 416 mA 88 % TRI 10-1223 +15 VDC 333 mA 15 VDC 333 mA 87 % TRI 10-2410 3.3 VDC 2 700 mA 81 % 5.1 VDC 2 000 mA 84 % TRI 10-2411 TRI 10-2412 12 VDC 833 mA 87 % 18 - 36 VDC TRI 10-2413 15 VDC 666 mA 88 % (24 VDC nom.) TRI 10-2415 24 VDC 416 mA 88 % TRI 10-2422 +12 VDC 416 mA 12 VDC 416 mA 88 % TRI 10-2423 +15 VDC 333 mA 15 VDC 333 mA 87 % TRI 10-4810 3.3 VDC 2 700 mA 81 % TRI 10-4811 5.1 VDC 2 000 mA 84 % 12 VDC 833 mA 87 % TRI 10-4812 36 - 75 VDC TRI 10-4813 15 VDC 666 mA 88 % (48 VDC nom.) TRI 10-4815 24 VDC 416 mA 87 % TRI 10-4822 +12 VDC 416 mA 12 VDC 416 mA 87 % TRI 10-4823 +15 VDC 333 mA 15 VDC 333 mA 87 % Page 1 / 4 www.tracopower.com January 18, 2021TRI 10 Series, 10 Watt Input Specifications Input Current - At no load 12 Vin models: 12 mA typ. 24 Vin models: 8 mA typ. 48 Vin models: 6 mA typ. - At full load 12 Vin models: 960 mA typ. 24 Vin models: 480 mA typ. 48 Vin models: 240 mA typ. Surge Voltage 12 Vin models: 25 VDC max. (1 s max.) 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) Under Voltage Lockout 12 Vin models: 7 VDC min. / 8 VDC typ. 24 Vin models: 15 VDC min. / 16 VDC typ. 48 Vin models: 31 VDC min. / 33 VDC typ. Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Pi-Type Output Specifications Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.5% max. dual output models: 0.5% max. - Load Variation (0 - 100%) single output models: 0.5% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) - Voltage Balance dual output models: 2% max. (symmetrical load) - Cross Regulation dual output models: 5% max. (25% / 100% asym. load) Ripple and Noise - 20 MHz Bandwidth 50 mVp-p typ. (w/ 10 F MLCC) 70 mVp-p max. (w/ 10 F MLCC) Capacitive Load - single output 3.3 Vout models: 4 700 F max. 5.1 Vout models: 3 300 F max. 12 Vout models: 560 F max. 15 Vout models: 360 F max. 24 Vout models: 140 F max. - dual output 12 / -12 Vout models: 280 / 280 F max. 15 / -15 Vout models: 180 / 180 F max. Minimum Load Not required Start-up Time 30 ms typ. / 60 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 190% max. of Iout max. 150% typ. of Iout max. Overvoltage Protection 125% typ. of Vout nom. Transient Response - Response Deviation 5% max. (75% to 100% Load Step) - Response Time 300 s typ. (75% to 100% Load Step) Safety Specifications Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 - Certification Documents www.tracopower.com/overview/tri10 Pollution Degree PD 2 Over Voltage Category OVC II All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 4 www.tracopower.com January 18, 2021