DC/DC Medical Converter TRV 1M Series, 1 Watt I/O isolation 5000 VAC (reinforced) Short circuit protection Semi-regulated outputs ES 60601-1 IEC 60601-1 Input voltage ranges (10%): UL 62368-1 IEC 62368-1 5, 12, 15, 24 VDC The TRV 1M is a series of 1 Watt DC/DC converters in a compact SIP-9 pack- Operating temperature range age with reinforced isolation of 5000 VAC for medical and industrial applica- -40 to +85 C without derating tions. The series offers models with different input voltages (10%) between 5 Certification according to IEC/EN/ES and 24 VDC. With a continuous short circuit protection and a low leakage cur- 60601-1 3rd edition for 2xMOPP and rent of less than 2 A, this converter series is especially suited to protect any IEC/EN/UL 62368-1 connected interfaces or applied parts to patients. Featuring semi-regulated out- puts this series provides a good level of regulation without affecting the cost ef- Low leakage current < 2 A ficiency. It is an ideal solution for applications where a completely unregulated Efficiency up to 85% DC/DC converter would not meet you regulation requirements and therefore opens up the overall application range of this series. Together with an operat- Operation up to 5000 m altitude ing temperature range from -40 to +85C without derating and certifications according to IEC/EN/ES 60601-1 3rd ed. for 2xMOPP and IEC/EN/UL 5-year product warranty 62368-1 this series is suitable for many different applications where a medical isolation system and short circuit protection is needed. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TRV 1-0510M 3.3 VDC 303 mA 80 % TRV 1-0511M 5 VDC 200 mA 82 % TRV 1-0512M 12 VDC 83 mA 85 % 4.5 - 5.5 VDC TRV 1-0513M 15 VDC 67 mA 84 % (5 VDC nom.) TRV 1-0521M +5 VDC 100 mA 5 VDC 100 mA 85 % TRV 1-0522M +12 VDC 42 mA 12 VDC 42 mA 85 % TRV 1-0523M +15 VDC 34 mA 15 VDC 34 mA 84 % TRV 1-1210M 3.3 VDC 303 mA 80 % TRV 1-1211M 5 VDC 200 mA 82 % TRV 1-1212M 12 VDC 83 mA 84 % 9.6 - 14.4 VDC TRV 1-1213M 15 VDC 67 mA 83 % (12 VDC nom.) TRV 1-1221M +5 VDC 100 mA 5 VDC 100 mA 82 % TRV 1-1222M +12 VDC 42 mA 12 VDC 42 mA 83 % TRV 1-1223M +15 VDC 34 mA 15 VDC 34 mA 83 % TRV 1-1510M 3.3 VDC 303 mA 79 % TRV 1-1511M 5 VDC 200 mA 83 % TRV 1-1512M 12 VDC 83 mA 84 % 12 - 18 VDC TRV 1-1513M 15 VDC 67 mA 84 % (15 VDC nom.) +5 VDC 100 mA 5 VDC 100 mA 82 % TRV 1-1521M TRV 1-1522M +12 VDC 42 mA 12 VDC 42 mA 83 % TRV 1-1523M +15 VDC 34 mA 15 VDC 34 mA 83 % TRV 1-2410M 3.3 VDC 303 mA 78 % TRV 1-2411M 5 VDC 200 mA 82 % TRV 1-2412M 12 VDC 83 mA 83 % 19.2 - 28.8 VDC TRV 1-2413M 15 VDC 67 mA 83 % (24 VDC nom.) TRV 1-2421M +5 VDC 100 mA 5 VDC 100 mA 80 % TRV 1-2422M +12 VDC 42 mA 12 VDC 42 mA 81 % TRV 1-2423M +15 VDC 34 mA 15 VDC 34 mA 81 % Note - 5 Vin models: If the input will be switched electromechanically, use an external 100 F/10 V E/C. to avoid voltage transient. Page 1 / 4 www.tracopower.com February 12, 2021TRV 1M Series, 1 Watt Input Specifications Input Current - At no load 5 Vin models: 30 mA typ. 12 Vin models: 30 mA typ. 15 Vin models: 15 mA typ. 24 Vin models: 10 mA typ. Surge Voltage 5 Vin models: 6 VDC max. (1 s max.) 12 Vin models: 25 VDC max. (1 s max.) 15 Vin models: 25 VDC max. (1 s max.) 24 Vin models: 40 VDC max. (1 s max.) Recommended Input Fuse 5 Vin models: 500 mA (slow blow) 12 Vin models: 315 mA (slow blow) 15 Vin models: 315 mA (slow blow) 24 Vin models: 160 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Output Specifications Voltage Set Accuracy 3.5% max. (60% load: 3.3, 5, 5 Vout models) 3.5% max. (90% load: other models) Regulation - Input Variation (1% Vin step) single output models: 0.2% max. dual output models: 0.2% max. - Load Variation (10 - 100%) single output models: 10% max. (3.3, 5 Vout models) 7% max. (other models) dual output models: 7% max. (Output 1) 7% max. (Output 2) (10% max. for 5 Vout model) - Cross Regulation dual output models: 6% max. (25% / 100% asym. load) Ripple and Noise - 20 MHz Bandwidth 75 mVp-p typ. 100 mVp-p max. Capacitive Load - single output 3.3 Vout models: 2 000 F max. 5 Vout models: 820 F max. 12 Vout models: 470 F max. 15 Vout models: 470 F max. - dual output 5 / -5 Vout models: 470 / 470 F max. 12 / -12 Vout models: 220 / 220 F max. 15 / -15 Vout models: 220 / 220 F max. Minimum Load Not required Temperature Coefficient 0.03 %/K max. Short Circuit Protection Continuous, Automatic recovery Safety Specifications Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 - Medical Equipment EN 60601-1 IEC 60601-1 ANSI/AAMI ES 60601-1 2 x MOPP (Means Of Patient Protection) www.tracopower.com/overview/trv1m - Certification Documents All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 4 www.tracopower.com February 12, 2021