Non-Isolated DC/DC Converter (POL) TSR 1WI Series, 1 A Ultra wide 8:1 input voltage range: 9-72 VDC Covers a majority of standard bus- and battery voltages Up to 93% efficiency - No heatsink required The TSR 1WI is a non-isolated POL converter series with an ultra wide 8:1 input Pin compatible with LMxx linear voltage range which comes in a standard SIP-3 package. Covering the majority regulators (SIP-3) of standard bus- and battery voltages this POL converter is a versatile solution Operating temperature range for many applications in distributed power systems where different input volt- -40 to +80C ages have to be handled. Being able to use the same converter in many differ- ent situations effectively reduces the bill of material (BOM) of a given applica- Low standby current tion. A high efficiency of up to 93% allows for an operating temperature range Excellent line/load regulation of -40 to +80C (up to 50C without derating) and makes them excellent drop-in replacements for less efficient LMxx linear regulators. With 1.0 A max. Protection against short circuit, output current and standard features such as low standby current, precise reg- overvoltage and overtemperature ulation and protection against short circuit, overvoltage and overload the TSR 3-year product warranty 1WI is suitable for many battery and distributed power applications. Models Order Code Output Current Input Voltage Output Voltage Efficiency max. Range nom. typ. TSR 1-4833WI 3.3 VDC 83 % (at 24 Vin) 87 % (at 24 Vin) TSR 1-4850WI 9 - 72 VDC (48 VDC nom.) 5 VDC 6.5 VDC 88 % (at 24 Vin) TSR 1-4865WI 1 000 mA TSR 1-4890WI 14 - 72 VDC (48 VDC nom.) 9 VDC 90 % (at 24 Vin) TSR 1-48120WI 17 - 72 VDC (48 VDC nom.) 12 VDC 93 % (at 24 Vin) TSR 1-48150WI 21 - 72 VDC (48 VDC nom.) 15 VDC 93 % (at 24 Vin) 700 mA 33 - 72 VDC (48 VDC nom.) 24 VDC 92 % (at 48 Vin) TSR 1-48240WI Options on demand (backorder with MOQ - Horizontal mounting (see outline dimensions) non stocking item) Note - It is recommended to use an external input filter, please refer to application note: www.tracopower.com/overview/tsr1wi Page 1 / 4 www.tracopower.com April 7, 2021TSR 1WI Series, 1 A Input Specifications Input Current - At no load 12 mA typ. Recommended Input Fuse 3.3 Vout models: 1 000 mA (slow blow) 5 Vout models: 1 250 mA (slow blow) 6.5 Vout models: 1 600 mA (slow blow) 9 Vout models: 1 600 mA (slow blow) 12 Vout models: 1 600 mA (slow blow) 15 Vout models: 1 600 mA (slow blow) 24 Vout models: 1 250 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) www.tracopower.com/overview/tsr1wi Input Filter See application note: (Recommended external input filter proposal) Output Specifications Voltage Set Accuracy 2% max. Regulation - Input Variation (Vmin - Vmax) 0.5% max. - Load Variation (0 - 100%) 0.6% max. Ripple and Noise 3.3 Vout models: 50 mVp-p typ. (w/ 10 F X7R) (20 MHz Bandwidth) 5 Vout models: 50 mVp-p typ. (w/ 10 F X7R) 6.5 Vout models: 50 mVp-p typ. (w/ 10 F X7R) 9 Vout models: 50 mVp-p typ. (w/ 10 F X7R) 12 Vout models: 50 mVp-p typ. (w/ 10 F X7R) 15 Vout models: 50 mVp-p typ. (w/ 10 F X7R) 24 Vout models: 75 mVp-p typ. (w/ 4.7 F X7R) Capacitive Load 3.3 Vout models: 2 400 F max. 5 Vout models: 1 580 F max. 6.5 Vout models: 1 200 F max. 9 Vout models: 880 F max. 12 Vout models: 660 F max. 15 Vout models: 530 F max. 24 Vout models: 330 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Start-up Time 25 ms typ. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 180% typ. of Iout max. Transient Response - Peak Variation 125 mV typ. / 250 mV max. (50% Load Step) (24 Vout model, with external 4.7 F X7R) 90 mV typ. / 180 mV max. (50% Load Step) (other models, with external 10 F X7R) - Response Time 150 s typ. / 250 s max. (50% Load Step) EMC Specifications EMI Emissions - Conducted Emissions EN 55032 class A (with external filter) EN 55032 class B (with external filter) - Radiated Emissions EN 55032 class A (with external filter) EN 55032 class B (with external filter) External filter proposal: www.tracopower.com/overview/tsr1wi General Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature 40C to +80C - Case Temperature +105C max. - Storage Temperature 55C to +125C All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 4 www.tracopower.com April 7, 2021