Highlights TAA SmartPro 120V 2.2kVA 1.92kW Line-Interactive Federal Trade Agreements Act / Sine Wave UPS, 3U, 120/230V input, Network Card TAA Compliant for GSA Options, USB, DB9 Schedule purchases 2200VA / 2.2kVA / 1920W line MODEL NUMBER: SM2200RMDVTAA interactive 3U rack/tower UPS 0.9 power factor Maintains 120V output with 120V or 230V input, Sine wave output USB port, RS232, EPO and optional network management card slot Detailed status LEDs 95% line-mode efficiency, 2 switched load banks C20 inlet & 4 international input line cords, 4 5-15R & 4 5-15/20R outlets Package Includes SM2200RMDVTAA UPS system Description 5 international input power cables Tripp Lite s dual input voltage SM2200RMDVTAA line interactive UPS system maintains 120V nominal output USB, DB9, EPO cabling when powered by North American 120V or International 230V input. Protects a variety of computer, networking 2-9USTAND tower stand kit and other sensitive equipment types from blackouts, voltage fluctuations and transient surges. 3U rack / tower 2POSTRMKITHD two-post form factor with an installed depth of only 22.5 inches. Expandable battery runtime with optional BP48V24-2U rackmount kit and BP48V60RT3U external battery packs. Uninterruptible Power Supply (UPS) switches to battery-derived AC 4POSTRAILKIT output during power failures and extreme voltage variations. Line interactive Automatic Voltage Regulation (AVR) Owner s manual offers voltage boost during brownouts and voltage cut during overvoltages to maintain regulated 120v output over an input range of 89 to 148V or 212 to 286V. Includes C20 power inlet with set of 4 international cord sets and both NEMA 5-15R and 5-15/20R output receptacles. Network-grade AC surge and noise suppression. Communications interfaces support communications via USB, DB9 serial and slot for optional network management card. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. PowerAlert monitoring software is available via free download. Emergency Power Off (EPO) interface. Integrated 2-bank programmable PDU switching supports load shedding and remote-reboot of up to 2 individual connected devices. 3-stage metered current monitoring and battery charge status LEDs. 95% efficiency in line power mode reduces energy cost and BTU emissions. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Installation accessories for rackmount and upright tower form factors included. Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. Features SmartPro SM2200RMDVTAA dual-voltage line interactive UPS system maintains 120V nominal output with either 120V or 230V input power Ideal for voice, data and networking applications requiring 120V output from worldwide power sources Line interactive Automatic Voltage Regulation (AVR) offers voltage boost during brownouts and voltage cut during overvoltages Maintains continuous operation through blackouts, voltage fluctuations and surges Corrects line voltage conditions between 89 to 148V or 212 to 286V to 120V nominal output Standard internal battery set offers 30 minutes runtime at half load (960 watts) and 12 minutes at full load (1920 watts) 1 / 6 Extended runtime is available with optional BP48V24-2U / BP48V242UTAA (limit 1) OR BP48V60RT3U / BP48V60RT3UTAA (no limit) Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software (see manual) Following an extended power outage, the UPS will automatically restart into line-power mode, begin powering connected equipment and recharge the battery system, all without user interaction Includes C20 power inlet with set of 4 international cord sets to support 5-20P, Schuko, CEE 7 / EU1-16P, British BS1363A and Italian CEI 23-16 plug types Includes NEMA 5-15R and 5-15/20R output receptacles Network-grade AC surge and noise suppression Compatible with Tripp Lite UPS management card options WEBCARDLX and SNMPWEBCARD USB and DB9 ports enable data-saving unattended shutdown when used with Tripp Lite s PowerAlert software, available via FREE download from www.tripplite.com/poweralert HID-compliant USB port enables integration with built-in power management and auto shutdown features of Windows and Mac OS X Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces Emergency Power Off (EPO) interface Integrated 2-bank PDU switching supports load shedding and remote-reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs 95% efficiency in line power mode reduces energy cost and BTU emissions Utility power and voltage regulation LEDs Installation accessories for rackmount and upright tower form factors included Field-replaceable, hot-swappable internal batteries and external battery packs Specifications OUTPUT Output Volt Amp Capacity (VA) 2200 Output kVA Capacity (kVA) 2.2 Output Watt Capacity (Watts) 1920 Output kW Capacity (kW) 1.92 Power Factor 0.87 Nominal Output Voltage(s) 120V Supported Frequency Compatibility 50 / 60 Hz Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Battery +/- 5% Mode) Output Receptacles (4) 5-15R (4) 5-15/20R Load Management Receptacles Two switchable single-outlet 5-15R load banks Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) Pure Sine wave 2 / 6