Inductive sensor NI6U-EG08-AP6X Threaded barrel, M8 x 1 Stainless steel, 1.4404 Factor 1 for all metals Protection class IP68 Magnetic field immune High switching distance High switching frequency Integrated predamping protection Limited metal-free spaces DC 3-wire, 1030 VDC NO contact, PNP output Cable connection Type NI6U-EG08-AP6X Wiring diagram Ident-No. 4635800 Rated operating distance Sn 6 mm Mounting condition non-flush Assured sensing range (0,81 x Sn) mm Repeatability 2 % Temperature drift 10 % Hysteresis 315 Ambient temperature 0+70 Functional principle Inductive sensors detect metal objects con- Operating voltage 1030 Residual ripple 10 % U tactless and wear-free. uprox+ sensors have ss DC rated operational current 150 mA considerable advantages due to their patent- No-load currentI 15 mA ed multi-coil system. They excel in highest 0 Residual current 0.1 mA switching distances, maximum flexibility and Rated insulation voltage 0.5 kV operational reliability as well as efficient stan- Short-circuit protection yes/ cyclic dardization. Voltage drop atI 1.8 V e Wire breakage / Reverse polarity protection yes/ complete Output function 3-wire, NO contact, PNP Protection class Switching frequency 1 kHz Design threaded barrel, M8 x 1 Dimensions 41.6 Housing material Metal, V4A (1.4404) Material active face Plastic, PP-GF30 End cap Plastic, PP Tightening torque of housing nut 10 Nm Connection cable Cable quality 4 mm, LifYY-11Y, PUR, 2m Cable cross section 3 x 0.25 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP68 Switching state LED yellow 1 / 3 Hans Turck GmbH & Co.KG D-45472 Mlheim an der Ruhr Witzlebenstrae 7 Tel. 0208 4952-0 Fax 0208 4952-264 more turck.com www.turck.com Edition 2011-07-15T21:43:48+02:00Inductive sensor NI6U-EG08-AP6X Mounting instructions minimum distances Distance D 32 mm Distance W 18 mm Distance T 36 mm Distance S 12 mm Distance G 36 mm Distance N 12 mm Diameter of the active area B 8 mm All non-flush mountable uprox+ threaded barrel sen- sors can be screwed to the upper edge of the bar- rel. Thus safe operation is guaranteed with a reduced switching distance of max. 20 %. 2 / 3 Hans Turck GmbH & Co.KG D-45472 Mlheim an der Ruhr Witzlebenstrae 7 Tel. 0208 4952-0 Fax 0208 4952-264 more turck.com www.turck.com Edition 2011-07-15T21:43:48+02:00