DESCO INDUSTRIES INC. Technical Bulletin TB-7005 Reztore Topical Antistat Application Instructions Made in the United States of America Directions Surfaces: Apply Reztore Topical Antistat to the entire surface to be treated using either the pump or trigger spray bottle. Use a lint-free cloth to wipe the surface evenly. For rough or porous surfaces two coats may be needed to obtain proper protection. Figure 1. Reztore Topical Antistat 1 quart (1 litre) spray bottle 2.5 Gallon (10 litre) Bag-in-Box Figure 2. Applying Reztore Topical Antistat to the Description mat. Reztore Topical Antistat is a topical antistatic solution for use on dissipative and non-ESD surfaces. Other Surfaces - Keyboards: After Reztore Topical Antistat has been applied and Dampen a lint-free cloth or a lint-free swab with the surface dries, an antistatic and protective static Reztore Topical Antistat. Wipe surface to be dissipative coating is left behind. The static dissipative protected using either the cloth or swab. The swab will coating will allow charges to drain off when grounded. work best for tight spots like between keyboard keys. The antistatic properties will reduce triboelectric voltage Use the cloth to wipe the remaining surfaces of the to under 200 volts. Reztore Topical Antistat will keyboard or surface to be protected. enhance existing electrical properties of ESD surfaces and give non-ESD surfaces electrical properties until the hard coat is worn away. Reztore Topical Antistat does not leave behind any harmful insulative barriers. General Guidelines Reztore Topical Antistat can be used on a variety of surfaces, especially surfaces used in a static sensitive environment. Surfaces include but are not limited to: rubber, vinyl and polyethylene table and floor mats, field service kits, laminated table tops, tote boxes, epoxy, painted surfaces, plexiglass, glass, metal, 3-ring binders, computer screens, computer keyboards, shelving, push carts, conveyor belts, etc. Figure 3. Cleaning a keyboard with Reztore Topical Antistat When dry, Reztore Topical Antistat will leave a thin protective antistatic, as well as static dissipative coating on the surface. This enhances existing ESD surfaces and will give temporary electrical properties to insulative surfaces. DESCO INDUSTRIES INC. 3651 Walnut Avenue, Chino, CA 91710 (909) 627-8178 Web Site: DescoIndustries.com 2012 DESCO INDUSTRIES, INC. TB-7005 June 2012 Page 1 of 6 Employee OwnedSpecifications Limited Warranty Reztore Topical Antistat has zero ionic contamination, Desco Industries, Inc. expressly warrants that for a which will neither contaminate nor corrode sensitive period of one (1) year from the date of purchase, our components and assemblies. Reztore Topical Antistat will be free of defects in material. Within the warranty period, the material will Ion Level Limit of Detection be replaced at our option, free of charge. Call our (mg/l) (mg/l) Customer Service Department at 781-821-8370 or Bromide <3 3 00 44 (0) 1892-665313 in Europe for a Return Material Chloride <1 3 Authorization (RMA) and proper shipping instructions Fluoride <0.5 0.5 and address. You should include a copy of your original Nitrate 0.5 0.5 packing slip, invoice, or other proof of purchase date. Any Nitrite <0.5 0.5 material under warranty should be shipped prepaid to the Ortho-phosphate <5 5 Desco Industries, Inc. factory. Warranty replacements will Sulfate <3 3 take approximately two weeks. Meets conditions of clean room class 1 for above listed Warranty Exclusions ion contaminants per FED-STD-209C. THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES, Electrical Properties EXPRESSED AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A Surface Resistance 10E6 ohms to < 1 x 10E9 ohms PARTICULAR PURPOSE WHICH ARE SPECIFICALLY per ANSI/ESD S4.1 DISCLAIMED. The express warranty will not apply to defects or damage due to accidents, neglect, misuse, Triboelectric Charge <200 volts alterations, operator error, or failure to properly maintain, Charge Decay .02 sec. FTMS 101C, clean or repair products. Method 4046 Limit of Liability Testing In no event will Desco Industries, Inc. or any seller be It is recommended to test the surfaces after applying responsible or liable for any injury, loss or damage, to ensure that all insulative areas have been coated. direct or consequential, arising out of the use of or the Desco Industries recommends Reztore Surface & Mat inability to use the product. Before using, users shall Cleaner to thoroughly clean the surface before applying determine the suitability of the product for their intended Reztore Topical Antistat. Reztore Topical Antistat use, and users assume all risk and liability whatsoever in is specifically designed to leave behind an antistatic connection therewith. 9 as well as static dissipative coating of 10 ohms, to enhance and provide the static safe properties of the surface. Testing for either surface resistance point to point (RTT) or resistance to ground (RTG) will indicate if the surface is coated properly. FIELD TEST: For quick and easy verification of surface resistance we recommend the use of a megohmmeter. These are available from many Desco Industries companies. For testing of static fields, we recommend the use of a static field meter. These instruments are also available from many Desco Industries companies. NOTE: Reztore Topical Antistat does not have a set life span. The chemicals are not known to degrade over time when stored at the proper temperature conditions as stated in the Material Safety Data Sheet. We also recommend that the product be stored in its original container and be sealed when not in use. DESCO INDUSTRIES INC. 3651 Walnut Avenue, Chino, CA 91710 (909) 627-8178 Web Site: DescoIndustries.com 2012 DESCO INDUSTRIES, INC. TB-7005 Page 2 of 6 Employee Owned