Maxi Family 110V Input Actual size: 4.6 x 2.2 x 0.5in S 117 x 56 x 12,7mm CUNRTL S C US DC-DC Converter Module Features & Benefits Applications Railway/Transportation system applications including communications systems, DC input range: 66 154V (continuous) information display, lighting, control systems, ticket machines, passenger Isolated output entertainment, public address systems, door control, industrial power systems and power Encapsulated circuitry for shock and generation systems. vibration resistance For details on proper operation please refer to the: Extended temperature range Design Guide & Applications Manual for Maxi, Mini, Micro Family. (55 to +100C) Input surge withstand: 250V for 100ms DC output: 3.3 48V Absolute Maximum Ratings Programmable output: 10 to 110% Regulation: 0.2% no load to full load Parameter Rating Unit Notes Efficiency: Up to 90% +IN to IN voltage 0.5 to +260 V DC Maximum operating temp: 100C, PC to IN voltage 0.5 to +7.0 V full load DC PR to IN voltage 0.5 to +7.0 V Power density: up to 80W per cubic inch DC SC to OUT voltage 0.5 to +1.5 V Height above board: 0.43in. (10,9mm) DC Sense to OUT voltage 1.0 V Parallelable, with N+M fault tolerance DC Isolation voltage Low noise ZCS/ZVS architecture IN to OUT 3000 V Test voltage RMS RoHS Compliant (with F or G pin option) IN to base 1500 V Test voltage RMS OUT to base 500 V Test voltage Product Overview RMS Operating Temperature 55 to +100 C M-Grade These DC-DC converter modules use advanced power processing, control and Storage Temperature 65 to +125 C M-Grade packaging technologies to provide the 500 (260) F (C) <5 sec wave solder Pin soldering temperature performance, flexibility, reliability and cost 750 (390) F (C) <7 sec hand solder effectiveness of a mature power component. Mounting torque 5 (0.57) in-lbs (N-m) 6 each High frequency ZCS/ZVS switching provides high power density with low noise and high efficiency. Part Numbering V110A B e.g. V110A24C400BL Product Grade Temperatures (C) Output Power Pin Style Finish Baseplate Product Type Output Voltage Grade Operating Storage V P Blank: Short Tin/Lead Blank: Slotted OUT OUT 3V3 = 3.3V V = Standard E = - 10 to +100 - 20 to +125 L: Long Tin/Lead 2: Threaded 3.3V 150W, 200W 5 = 5V S = Enhanced C = - 20 to +100 - 40 to +125 S: Short ModuMate Gold 3: Through-hole 5V 200W, 300W efficiency 8 = 8V T = - 40 to +100 - 40 to +125 N: Long ModuMate Gold (avail. 12 8V 200W, 300W 12 = 12V V only) OUT H = - 40 to +100 - 55 to +125 F: Short RoHS Gold 12V 300W, 400W 15 = 15V M = - 55 to +100 - 65 to +125 G: Long RoHS Gold 15V 300W, 400W 24 = 24V K: Extra Long RoHS Gold 24V 300W, 400W 28 = 28V 28V 300W, 400W 36 = 36V 36V 300W, 400W 48 = 48V 48V 300W, 400W 110V Maxi Family Rev 3.2 vicorpower.com Page 1 of 14 06/2017 800 927.9474110V Input Module Family Electrical Characteristics Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. MODULE INPUT SPECIFICATIONS Parameter Min Typ Max Unit Notes Operating input voltage 66 110 154 V Per EN50155 and GBT-25119 DC Input surge withstand 250 V <100ms DC Undervoltage turn-on 64 65.4 V DC Undervoltage turn-off 54 56 V DC Overvoltage turn-off/on 155.5 161.7 169.4 V DC Disabled input current 1.3 mA PC pin low MODULE OUTPUT SPECIFICATIONS Parameter Min Typ Max Unit Notes Output voltage setpoint 1 % Of nominal output voltage. Nominal input full load 25C Line regulation 0.02 0.20 % Low line to high line full load Temperature regulation 0.002 0.005 % / C Over operating temperature range Power sharing accuracy 2 5 % 10 to 100% of full load Of nominal output voltage. For trimming below 90% Programming range 10 110 % of nominal, a minimum load of 10% of maximum rated power may be required. +OUT to OUT, +Sense to OUT Absolute Maximum Ratings 3.3V 0.5 to 4.7 V Externally applied DC 5V 0.5 to 7.0 V Externally applied DC 8V 0.5 to 10.9 V Externally applied DC 12V 0.5 to 16.1 V Externally applied DC 15V 0.5 to 20.0 V Externally applied DC 24V 0.5 to 31.7 V Externally applied DC 28V 0.5 to 36.9 V Externally applied DC 36V 0.5 to 47.4 V Externally applied DC 48V 0.5 to 62.9 V Externally applied DC Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information, please refer to output connections on page 9. THERMAL RESISTANCE AND CAPACITY Parameter Min Typ Max Unit Baseplate to sink flat, greased surface 0.08 C/Watt Baseplate to sink thermal pad (P/N 20263) 0.07 C/Watt Baseplate to ambient 4.9 C/Watt Baseplate to ambient 1000LFM 1.1 C/Watt Thermal capacity 165 Watt-sec/C 110V Maxi Family Rev 3.2 vicorpower.com Page 2 of 14 06/2017 800 927.9474