S 1 Fuse Terminal Blocks for Blade-Type Fuses 29 acc. to DIN 72581-3f, ISO 8820-3, Series 2002 2 2 0.25 2.5 (4) mm AWG 22 12 0.25 2.5 (4) mm AWG 22 12 400 V/6 kV/3 400 V/6 kV/3 I 10 A I 10 A N N Terminal block width 5.2 mm / 0.205 in Terminal block width 5.2 mm / 0.205 in L 10 12 mm / 0.43 in L 10 12 mm / 0.43 in 2 2 can be connected: 0.25 mm 4 mms+f-s 2 2 can be pushed in directly: 0.75 mm 4 mm and 2 2 0,75 mm 2,5 mminsulated ferrule, 12 mm/0.472 i < > < 66,5 mm /2.61 in > < 87,5 mm /3.45 in > Item no. Pack. unit Item no. Pack. unit 2-conductor fuse terminal blocks 4-conductor fuse terminal blocks gray 2002-1681 gray 2002-1881 - Individual arrangement: 10 A - Individual arrangement: 10 A - Block arrangement: 5 A - Block arrangement: 5 A Please note touchproof protection from 42 V Please note touchproof protection from 42 V Article-specific accessories End and intermediate plate, 1 mm/0.039 in thick End and intermediate plate, 1 mm/0.039 in thick orange 2002-1692 100 (4 x 25) orange 2002-1892 100 (4 x 25) gray 2002-1691 100 (4 x 25) gray 2002-1891 100 (4 x 25) Accessories Series 2002 Appropriate marker systems: WMB/Marker Strips/WMB Inline (see Full Line Catalog W4, Vol. 1, Sec. 14) Insulation stop, 5 pcs/strip 200 strips Protective warning marker, with high voltage symbol, black, The rated currents of the fuse cartridges are 2 light gray 2002-171 0.25-0.5 mm for 5 terminal blocks defined differently in international standards. 2 dark gray 2002-172 0.75-1 mm yellow 2002-115 100 (4 x 25) Due to the different current rating definitions, the recommended current-carrying permanent Push-in type jumper bars, light gray, insulated, I 25 A Staggered jumpers, light gray, insulated, I 25 A N N capacity of the fuses is max. 80% of their rated 2-way 2002-402 200 (8 x 25) 2-way 2002-472 100 (4 x 25) current according to DIN 72581 part 3 (for an 3-way 2002-403 200 (8 x 25) 3-way 2002-473 100 (4 x 25) ambient operating temperature of 23C). 4-way 2002-404 200 (8 x 25) 4-way 2002-474 100 (4 x 25) Selecting the correct fuse cartrigde is important 5-way 2002-405 100 (4 x 25) 5-way 2002-475 50 (2 x 25) for product safety within applications as well as : : : : the service life/operational reliability of the fuse 10-way 2002-410 100 (4 x 25) 12-way 2002-482 50 (2 x 25) cartrigdes. Fuse cartrigdes can operate perfectly as protection (break-off point) if they are properly Push-in type jumper bars, light gray, insulated, I 25 A Test plug adapter, for test plug 4 mm/0.157 in N selected and are used in accordance with 2009-174 100 (4 x 25) the manufacturers specifications. 1 - 3 2002-433 200 (8 x 25) In general it is necessary to test fuse cartridges 1 - 4 2002-434 200 (8 x 25) under normal conditions and operational failures 1 - 5 2002-435 100 (4 x 25) within your application. : : 2 1 - 10 2002-440 100 (4 x 25) Testing tap, for max. 2.5 mm /AWG 14 2009-182 100 (4 x 25) Modular TOPJOB S connector, Two-way marking adapter, for jumper contact slot pivotable 1 pole 2002-511 100 (4 x 25) 2002-121 50 (2 x 25) Spacer, modular 2002-549 100 (4 x 25) Test plug, with cable 500mm/17.7, 2 mm/0.079 in Blade-type fuses acc. to DIN 72581-3f / With regard to the product safety, it is in red 210-136 50 (5 x 10) ISO 8820-3 (not offered by WAGO) general necessary to test the fuse in the appliance under normal conditions and operational failures. 33 mm / < > 1.29 in < 38 mm /1.49 in > 33 mm / < > 1.29 in VOLUME 1 1 Fuse Disconnect Terminal Blocks with Pivotable Fuse Holder, 2 34 2.5 (4) mm /AWG 12, for Miniature Metric Fuses 5 x 20 mm, Series 2002 2 2 0.25 2.5 (4) mm AWG 22 12 0.25 2.5 (4) mm AWG 22 12 250 V/6 kV/3 250 V/6 kV/3 6.3 A 6.3 A Terminal block width 6.2 mm / 0.244 in Terminal block width 6.2 mm / 0.244 in L 10 12 mm / 0.43 in L 10 12 mm / 0.43 in 800 V = rated voltage 8 kV = rated surge voltage 3 = pollution degree (see also Full Line Catalog W4, Volume 1, Section 15) Nominal voltage and current are given by the LED or fuse Leakage current in case of blown fuse: < 66,5mm /2.62in > < 66,5mm /2.62in > LED 6 mA Item no. Pack. unit Item no. Pack. unit Description Fuse disconnect terminal block 2-conductor fuse terminal block with end plate, 2-conductor fuse terminal blocks with end plate, with pivotable fuse holder, without blown fuse indication with blown fuse indication by LED for DIN 35 rail, for miniature metric fuses 5 x 20 mm gray 2002-1611 50 gray 12 30 V 2002-1611/1000-541 50 5 x 20 mm gray 30 65 V 2002-1611/1000-542 50 5 x 20 mm gray 110 250 V 2002-1611/1000-836 50 Article-specific accessories End plate for fuse terminal blocks, 2 mm/0.079 in thick End plate for fuse terminal blocks, 2 mm/0.079 in thick gray 2002-991 100 (4x25) gray 2002-991 100 (4x25) orange 2002-992 100 (4x25) orange 2002-992 100 (4x25) Accessories Appropriate marker systems: WMB/Marker Strips/WMB Inline (see Full Line Catalog W4, Volume 1, Section 14) Insulation stop, 5 pcs/strip 200 strips Insulation stop, 5 pcs/strip 200 strips 2 2 light gray 2002-171 0.25-0.5 mm light gray 2002-171 0.25-0.5 mm 2 2 dark gray 2002-172 0.75-1 mm dark gray 2002-172 0.75-1 mm must be singularized must be singularized Protective warning marker, with high voltage symbol, black, Protective warning marker, with high voltage symbol, black, for 5 terminal blocks for 5 terminal blocks yellow 2002-115 100 (4 x 25) yellow 2002-115 100 (4 x 25) must be singularized must be singularized Push-in type jumper bars, light gray, insulated, I 25 A Push-in type jumper bars, light gray, insulated, I 25 A N N 2-way 2004-402 200 (8 x 25) 2-way 2004-402 200 (8 x 25) 3-way 2004-403 200 (8 x 25) 3-way 2004-403 200 (8 x 25) 4-way 2004-404 200 (8 x 25) 4-way 2004-404 200 (8 x 25) 5-way 2004-405 100 (4 x 25) 5-way 2004-405 100 (4 x 25) : : : : 10-way 2004-410 100 (4 x 25) 10-way 2004-410 100 (4 x 25) Push-in type jumper bars, light gray, insulated, I 25 A Push-in type jumper bars, light gray, insulated, I 25 A N N 1 - 3 2004-433 200 (8 x 25) 1 - 3 2004-433 200 (8 x 25) 1 - 4 2004-434 200 (8 x 25) 1 - 4 2004-434 200 (8 x 25) 1 - 5 2004-435 100 (4 x 25) 1 - 5 2004-435 100 (4 x 25) : : : : 1 - 10 2004-440 100 (4 x 25) 1 - 10 2004-440 100 (4 x 25) Test plug, with cable 500 mm/17.7, 2 mm/0.079 in Test plug, with cable 500 mm/17.7, 2 mm/0.079 in red 210-136 50 (5 x 10) red 210-136 50 (5 x 10) VOLUME 1 < 57,2mm /2.26in > < 57,2mm /2.26in >