Data sheet Weidmller Interface GmbH & Co. KG CP DC UPS 24V 20A/10A Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com The UPS control unit together with the associated battery General ordering data module and the power supply unit form a complete DC UPS system. In normal operation, the input voltage from Version UPS control unit the UPS control unit is connected directly to the load. In Order No. 1370050010 Type CP DC UPS 24V 20A/10A the event of a mains failure (drop of the DC input voltage) GTIN (EAN) 4050118202335 the system switches instantly to battery operation. Qty. 1 pc(s). Once the mains supply has been restored, the system switches back to normal operation and the battery is fully recharged by the integrated charger. Three relay outputs, as well as three additional active transistor outputs and a control input to lock battery operation, provide full remote control by means of SPS or DCS control. Numerous modes of operation and an easy- to-use status display provide rapid fault diagnosis and optimum customisation to the application. Creation date September 29, 2021 10:59:32 AM CEST Catalogue status 27.09.2021 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG CP DC UPS 24V 20A/10A Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Technical data Dimensions and weights Depth 150 mm Depth (inches) 5.905 inch Height 130 mm Height (inches) 5.118 inch Width 66 mm Width (inches) 2.598 inch Net weight 1,139 g Temperatures Storage temperature -40 C...85 C Operating temperature -25 C...70 C Humidity 5...95 %, no condensation Probability of failure SIL in compliance with IEC 61508 None Environmental Product Compliance REACH SVHC Lead 7439-92-1 Battery module Parallel connection option Yes, max. 2 Rated voltage 24 V Storage medium 1.3 Ah, 3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah, Selectable with rotary switch Integrated battery charger Battery availability test every minute Charging current 0.15 CA Charging feature Charging voltage (temperature IU characteristic curve compensated) 27, 48 V 20C Temperature coefficient - 48 mV / C Operating interfaces and control inputs Function DIP switch Inversion of transistor Output current selector switch outputs, Operation without temperature probe 20 A, 10 A Remote disconnection (Interlock) Selector switch battery 1.3 Ah, 3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah, No Battery, Yes Service Selector switch buffer times 0.5 min, 1 min, 3 min, 5 Temperature probe min, 10 min, 20 min, 30 min, 45 min, , w/0 NTC 100 k Input DC current consumption max. 200 mA (without DC input voltage range battery), max. 0.5 A (with fully charged battery) 20...30 V DC Input current 13A (for 10A), 23A (for Input fuse (internal) 20A) Yes Max. approved input current 28 A Rated input voltage 24 V DC Wire connection method Screw connection Creation date September 29, 2021 10:59:32 AM CEST Catalogue status 27.09.2021 / We reserve the right to make technical changes. 2