Data sheet Weidmller Interface GmbH & Co. KG ACT20P Klingenbergstrae 16 ACT20P-CMT-60-RC-S D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com ACT20P: The flexible solution Precise and highly functional signal converters Simple configuration via display (Pro DCDC II), FDT/ DTM software or DIP switch Release levers simplify handling More space in the control cabinet, from 12.5 mm wide for two channels General ordering data Type ACT20P-CMT-60-RC-S Order No. 1510390000 Version Current-measuring transducer, Limit value monitoring, Signal converter/isolator, Current monitoring, Screw connection, Input measurement range: configurable, 040/50/60 A AC or DC GTIN (EAN) 4050118325485 Qty. 1 pc(s). Creation date November 7, 2017 5:39:19 PM CET Catalogue status 20.10.2017 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG ACT20P Klingenbergstrae 16 ACT20P-CMT-60-RC-S D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com Technical data Dimensions and weights Width 22.5 mm Width (inches) 0.886 inch Height 117.2 mm Height (inches) 4.614 inch Depth 113.6 mm Depth (inches) 4.472 inch Weight 180 g Net weight 158 g Temperatures Humidity 0...95 % (no condensation) Operating temperature -25 C...60 C Storage temperature -40 C...85 C Probability of failure MTTF 100 Years Input Number of inputs Input signal Current-carrying cable in feed-through hole, 1 Diameter 10.5 mm Input measurement range Input frequency AC: 15700 Hz (true root configurable, 0 mean square), AC: 50 Hz 40/50/60 A AC or DC (arithmetic average) General data Accuracy < 0.75 % FSR, < 1.5 % FSR Configuration with measurement range DIP switch and 50/60 A AC potentiometer Galvanic isolation 3-way isolator, between Mounting rail input output supply TS 35 Step response time < 300 ms Supply voltage 16,8 V31,2 V Temperature coefficient typ. 0.04 % / K, max. 0.09 % / K Insulation coordination EMC standards Galvanic isolation 3-way isolator, between IEC 61326-1:2012 input output supply Impulse withstand voltage 6.4 kV (1.2/50 s) Pollution severity 2 Rated voltage Standards IEC 61010-1:2010, 3rd Edition, IEC 61010-2-201:2013, 1st 300 V AC eff Edition, EN 61326-1 Surge voltage category III Test voltage 4 kV Output (digital) Alarm function Surge current, Under- Number of digital outputs current, Alarm delay: 010 s, Hysteresis 5% / 10% 1 Type Relay, 1 CO contact, Max. switching voltage, DC normal / inverse adjustment 24 V Max. switching voltage, AC 250 V Rated switching current 6 A Creation date November 7, 2017 5:39:19 PM CET Catalogue status 20.10.2017 / We reserve the right to make technical changes. 2