Data sheet Weidmller Interface GmbH & Co. KG AMG ELM-6 Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Similar to illustration Efficient machine and facility operation calls for fail-safe and maintenance-friendly control voltage distribution that can be installed in a time and space-saving manner. With the new maxGUARD system, the terminal blocks (previously installed separately) for distributing potential to the outputs of the electronic load monitors become an integral part of a 24 V DC control voltage distribution system. The innovative combination of load monitoring and potential distribution saves time during installation, increases safety against failure and reduces the amount of space required on the terminal rail by 50%. General ordering data Version Electronic load monitoring, 6 A, 24 V DC Order No. 2080360000 Type AMG ELM-6 GTIN (EAN) 4050118419306 Qty. 1 pc(s). Creation date March 26, 2022 1:36:34 AM CET Catalogue status 11.03.2022 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG AMG ELM-6 Klingenbergstrae 26 D-32758 Detmold Germany www.weidmueller.com Technical data Dimensions and weights Depth 96.5 mm Depth (inches) 3.799 inch Height 125 mm Height (inches) 4.921 inch Width 6.1 mm Width (inches) 0.24 inch Net weight 43 g Temperatures Storage temperature -40 C...85 C Operating temperature -25 C...55 C Environmental Product Compliance REACH SVHC Lead 7439-92-1 Input Current consumption (full load) I +30 mA Current consumption (idle) OUT 25 mA DC input voltage range 1830 V DC Input fuse (internal) Yes Rated input voltage 24 V DC Surge protection Suppressor diode max. admissible residual ripple at the input 100 mVpp Output Capacitive load 15,000 F Connection system PUSH IN Rated current 6 A Surge protection Suppressor diode Switch-on delay 1 s Triggering characteristic see characteristic curve adjustable rated current Yes General data Conformal coating No Function key Activation time < 3s, Reset, ON MTTF According to Standard SN 29500 Operating time (hours), min. 2.49 Mh Ambient temperature 40 C Input voltage 24 V Output power 144 W Duty cycle 100 % Operating temperature -25 C...55 C Power loss, idling 492 mW Relay to activate the output No Surge voltage category III Insulation coordination Surge voltage category III Connection data (output) Conductor cross-section, AWG/kcmil , Conductor cross-section, AWG/kcmil , max. 12 min. 26 Conductor cross-section, flexible , max. 2.5 mm Conductor cross-section, flexible , min. 0.14 mm Conductor cross-section, rigid , max. 2.5 mm Conductor cross-section, rigid , min. 0.14 mm Connection system PUSH IN Number of terminals 2 (+ / -) Creation date March 26, 2022 1:36:34 AM CET Catalogue status 11.03.2022 / We reserve the right to make technical changes. 2