Datasheet Weidmller Interface GmbH & Co. KG TERMOPTO Klingenbergstrae 16 TOP 5VDC/48VDC 0,5A D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-2083 www.weidmueller.com The TERMOPTO opto module is used in industrial applications in which electrical isolation and signal conditioning without switching amplification is sufficient. The compact design in terminal-block format saves space on the rail and offers the option of a pluggable cross-connection. The choice between 10 input voltages and 3 output voltages as well as between screw or Push In connection technology gives 60 variations for different applications. The integrated protective circuit ensures sufficient protection in applications with resitive as well as slightly inductive and capacitive loads. For purely inductive, capacitive or comparable loads with high switch-on and switch-off peaks, such as solenoid valves or filament lamps, ensure that the module is dimensioned appropriate or an additional safeguard is used. General ordering data Order No. 8950960000 Part designation TOP 5VDC/48VDC 0,5A Version TERMOPTO, Solid-state relay, 5...48 V DC, 500 mA, PUSH IN spring connection GTIN (EAN) 4032248742325 Qty. 10 pc(s). Creation date October 15, 2010 8:48:17 AM CEST Last update 30.08.2010 / We reserve the right to make technical changes. 1Datasheet Weidmller Interface GmbH & Co. KG TERMOPTO Klingenbergstrae 16 TOP 5VDC/48VDC 0,5A D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-2083 www.weidmueller.com Technical data Dimensions Length 79.5 mm Width 6.1 mm Height 55 mm Temperature Ambient temperature (operational) -20 C...+60 C Storage temperature -40 C...+80 C Approvals Approvals institutes CULUS CE Control side Dropout voltage 2 V DC Input frequency < 200 Hz Power rating Protective circuit, control side Varistor, reverse polarity < 40 mW protection Rated control voltage 5 V DC Status display on control side Green LED making voltage 4 V DC General data Standards Humidity 5...95 % rel. humidity T = 40C, no condensation EN 50178, IEC 62314, UL508 u Flammability class UL 94 V-0 Conductor connection system PUSH IN spring connection DIN Rail compatibility TS 35 Solid-state type Transistor Insulation coordination (EN 50 178) Clearance and creepage distances for Overvoltage category control/load side > 3 mm III Pollution severity 2 Rated impulse withstand voltage 4 kV Rated voltage 300 V Load side Continuous current 500 mA Leakage current < 10 A Load category DC1 Protective circuit, load side Diode Rated switching current 500 mA Rated switching voltage 5...48 V DC Short-circuit-proof No Status indicator load side No Switch-off delay < 200 s Switch-on delay < 20 s Voltage drop at max. load < 1 V Classifications ETIM 3.0 EC001504 eClass 5.1 27-27-09-90 eClass 6.0 27-27-09-90 Creation date October 15, 2010 8:48:17 AM CEST Last update 30.08.2010 / We reserve the right to make technical changes. 2