Data sheet Weidmller Interface GmbH & Co. KG TERMOPTO Klingenbergstrae 16 TOP 120VAC/230VAC 0,1A D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com TERMOPTO solid-state relay 230 VAC 0.1 A output version, with AC or DC input, available in different versions: With PUSH IN connection In 6.1 mm width With various input protection circuits (free-wheel diode, varistor) Pluggable cross-connections Enclosed design General ordering data Type TOP 120VAC/230VAC 0,1A Order No. 8951280000 Version TERMOPTO, solid-state relais, 1 NO contact (Triac (zero-cross switch)), Rated control voltage: 120 V AC 20 % , Rated switching voltage: 24...230 V AC, Continuous current: 100 mA, PUSH IN GTIN (EAN) 4032248742059 Qty. 10 pc(s). Creation date June 13, 2017 10:54:00 AM CEST Catalogue status 02.06.2017 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG TERMOPTO Klingenbergstrae 16 TOP 120VAC/230VAC 0,1A D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com Technical data Dimensions and weights Width 6.1 mm Width (inches) 0.24 inch Height 79.4 mm Height (inches) 3.126 inch Depth 55 mm Depth (inches) 2.165 inch Net weight 19.8 g Temperatures Humidity 595% rel. humidity, T = Operating temperature u 40C, no condensation -20 C...60 C Storage temperature -40 C...80 C Probability of failure MTTF 2,500 Years Control side Rated control voltage 120 V AC 20 % Nominal control current 8.5 mA AC Power rating 1 VA Cut-in / dropout voltage 96 V / 48 V AC Status indicator Green LED Protective circuit Varistor Load side Rated switching voltage 24...230 V AC Continuous current 100 mA Rated switching current 100 mA Load category AC1 Switch-on delay < 22 ms Switch-off delay < 18 ms Voltage drop at max. load < 1.8 V Leakage current < 1 mA Short-circuit-proof No Protective circuit, load side Varistor, RC element max. switching frequency (AC control voltage) 10 Hz Contact data Contact type 1 NO contact (Triac (zero- cross switch)) General data UL 94 flammability rating V-0 Insulation coordination Rated voltage 300 V Pollution severity 2 Surge voltage category Clearance and creepage distances for III control side - load side > 3 mm Dielectric strength for control side - load Impulse withstand voltage 1.2 kV / 1 min. side eff 4 kV (1.2/50 s) Protection degree IP20 Further details of approvals / standards Standards DIN EN 50178, IEC Certificate no. (cULus) 62314, UL508 E223474 Creation date June 13, 2017 10:54:00 AM CEST Catalogue status 02.06.2017 / We reserve the right to make technical changes. 2