9926 Series Branch Rated Circuit BreakersAC Version Circuit Breakers 9926 Series 9926 Series Hydraulic Magnetic Type Single Pole Double Pole Single pole and double pole versions 120/240 VAC, 50/60 Hz Up to 25A Just 13 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering Data Type: Single Pole Type: Double Pole Current Ratings Part No. Current Ratings Part No. (amps) TS 35 Description (amps) TS 35 Description 0.5 9926251000 QL-1-13-DM-KM-0.5 0.5 9926252000 QL-2-13-DM-KM-0.5 1 9926251001 QL-1-13-DM-KM-01 1 9926252001 QL-2-13-DM-KM-01 2 9926251002 QL-1-13-DM-KM-02 2 9926252002 QL-2-13-DM-KM-02 3 9926251003 QL-1-13-DM-KM-03 3 9926252003 QL-2-13-DM-KM-03 4 9926251004 QL-1-13-DM-KM-04 4 9926252004 QL-2-13-DM-KM-04 5 9926251005 QL-1-13-DM-KM-05 5 9926252005 QL-2-13-DM-KM-05 6 9926251006 QL-1-13-DM-KM-06 6 9926252006 QL-2-13-DM-KM-06 7 9926251007 QL-1-13-DM-KM-07 7 9926252007 QL-2-13-DM-KM-07 8 9926251008 QL-1-13-DM-KM-08 8 9926252008 QL-2-13-DM-KM-08 10 9926251010 QL-1-13-DM-KM-10 10 9926252010 QL-2-13-DM-KM-10 13 9926251013 QL-1-13-DM-KM-13 13 9926252013 QL-2-13-DM-KM-13 15 9926251015 QL-1-13-DM-KM-15 15 9926252015 QL-2-13-DM-KM-15 16 9926251016 QL-1-13-DM-KM-16 16 9926252016 QL-2-13-DM-KM-16 20 9926251020 QL-1-13-DM-KM-20 20 9926252020 QL-2-13-DM-KM-20 25 9926251025 QL-1-13-DM-KM-25 25 9926252025 QL-2-13-DM-KM-25 Technical Data 9926 Series AC Version - dimensions in mm (in.) Voltage 120/240 VAC, 50/60Hz 74 Current (2.91) minimum 0.5A 13 26 66 (0.51) (1.02) (2.6) maximum 25A Interrupting capacity 10,000A Dielectric strength 1500V, 50/60Hz Insulation resistance 100MM Operating life 10000 mechanical operations Operating temperature -40+65C Wire size* 0.5-15A: 14AWG min., 10AWG max. 20-25A: 10AWG min. 19 Torque 20 in.-lb (0.75) 13 (0.51) 32 Approval (1.26) UL 489 listed, CSA C22.2 No. 5-02, CE, VDE 5 45 (0.2) (1.77) Accessories Part No. 64.8 Bus-bar (1 pole, insulated, 1 m) 67101904 (2.55) Bus-bar (2 pole, insulated, 1 m) 67101972 9926 SeriesAC version Trip Curve 9926 SeriesAC version Trip Curve Bus-bar end cap, 1 pole 67101973 Bus-bar end cap, 2 pole 67101974 1000 1000 Operating Characteristics Operating Characteristics Power lug, straight 67101960 Curve KM Curve 1 Power lug, 90 67101961 100 100 Ambient Temperature 30C Ambient Temperature 30C Lock-out handle 67101913 *Wire sizes: gauges specified are the minimum allowable as per CSA 10 and UL standards. 10 The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length 1 1 (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). 10 10 The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. 1 1 Trip CurvesHydraulic Magnetic Type Typical time/current characteristics at 30C 0.1 0.1 Sample trip characteristics - KM 125% 150% 200% 400% 600% 800% 1000% 0.01 0.01 minimum 15 8 4 0.7 0.09 0.007 0.005 (sec) 0.001 0.001 maximum 300 90 28 4 1.5 0.6 0.4 (sec) Although the 9926 series uses a magnetic only trip mechanism, CSA (%) Rated Current (%) Rated Current testing indicates a trip characteristic similar to thermal magnetic trip mechanisms. No de-rating is required at elevated temperatures. Trip Curve 1 applies to the following part numbers where Additional trip curves and amp ratings are availableX is the current rating: Single Pole 99262512XX Double Pole 99262522XX upon request. 3 Tripping Time 71.4 Seconds Minutes (2.81) 100 105 28.5 130 (1.12) 150 200 300 400 500 1000 57 17.9 (2.24) (0.7) 1500 2000 2500 3000 4000 5000 92.8 (3.65) Tripping Time Seconds Minutes 100 105 125 150 200 300 400 500 1000 1500 2000 2500 3000 4000 50009926 Series Branch Rated Circuit BreakersAC Version with Contacts Circuit Breakers with 9926 Series 9926 Series 9926 Series Auxiliary switch, Trip alarm, Single Pole Single Pole Trip Single Pole Combination Combination of both w/ Auxiliary Contact (Alarm Contact) (Auxiliary & Alarm Contact) AC voltages (120/240V) Single and double pole versions UL 489 and CSA listed Factory fitted auxiliary or trip alarm Compact 6.5mm width Attached to right hand side of circuit breaker Technical Data Type: Single Pole Aux Type: Single Pole Trip Type: Single Pole Combo Voltage 120/240 VAC, 50/60Hz Current Current Current Current Ratings Ratings Ratings (amps) Part No. Description (amps) Part No. Description (amps) Part No. Description minimum 0.5A maximum 25A 1 9926261001 QL-A-1-13-DM-KM-1 1 9926271001 QL-T-1-13-DM-KM-1 1 9926281001 QL-AT-1-13-DM-KM-1 Interrupting capacity 10,000A 2 9926261002 QL-A-1-13-DM-KM-2 2 9926271002 QL-T-1-13-DM-KM-2 2 9926281002 QL-AT-1-13-DM-KM-2 5 9926261005 QL-A-1-13-DM-KM-5 5 9926271005 QL-T-1-13-DM-KM-5 5 9926281005 QL-AT-1-13-DM-KM-5 Dielectric strength 1500V, 50/60Hz 10 9926261010 QL-A-1-13-DM-KM-10 10 9926271010 QL-T-1-13-DM-KM-10 10 9926281010 QL-AT-1-13-DM-KM-10 Insulation resistance 100MM Operating life 10000 15 9926261015 QL-A-1-13-DM-KM-15 15 9926271015 QL-T-1-13-DM-KM-15 15 9926281015 QL-AT-1-13-DM-KM-15 mechanical operations 20 9926261020 QL-A-1-13-DM-KM-20 20 9926271020 QL-T-1-13-DM-KM-20 20 9926281020 QL-AT-1-13-DM-KM-20 Operating temperature -40+65C 25 9926261025 QL-A-1-13-DM-KM-25 25 9926271025 QL-T-1-13-DM-KM-25 25 9926281025 QL-AT-1-13-DM-KM-25 Wire size* 0.5-15A: 14AWG min., 10AWG max. 20-25A: 10AWG min. 9926 Series 9926 Series 9926 Series Torque 20 in.-lb Double Pole Double Pole Trip Double Pole Combination Approval w/ Auxiliary Contact (Alarm Contact) (Auxiliary & Alarm Contact) UL 489 listed, CSA C22.2 No. 5-02, CE, VDE *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is 1720600000. Type: Double Pole Aux Type: Double Pole Trip Type: Double Pole Combo Current Current Current Ratings Ratings Ratings (amps) Part No. Description (amps) Part No. Description (amps) Part No. Description 1 9926262001 QL-A-2-13-DM-KM-1 1 9926272001 QL-T-2-13-DM-KM-1 1 9926282001 QL-AT-2-13-DM-KM-1 2 9926262002 QL-A-2-13-DM-KM-2 2 9926272002 QL-T-2-13-DM-KM-2 2 9926282002 QL-AT-2-13-DM-KM-2 5 9926262005 QL-A-2-13-DM-KM-5 5 9926272005 QL-T-2-13-DM-KM-5 5 9926282005 QL-AT-2-13-DM-KM-5 10 9926262010 QL-A-2-13-DM-KM-10 10 9926272010 QL-T-2-13-DM-KM-10 10 9926282010 QL-AT-2-13-DM-KM-10 15 9926262015 QL-A-2-13-DM-KM-15 15 9926272015 QL-T-2-13-DM-KM-15 15 9926282015 QL-AT-2-13-DM-KM-15 20 9926262020 QL-A-2-13-DM-KM-20 20 9926272020 QL-T-2-13-DM-KM-20 20 9926282020 QL-AT-2-13-DM-KM-20 25 9926262025 QL-A-2-13-DM-KM-25 25 9926272025 QL-T-2-13-DM-KM-25 25 9926282025 QL-AT-2-13-DM-KM-25 9926 SeriesAC version Trip Curve Dual Mount Dimensions in mm (in.) 1000 31.3 Trip CurvesHydraulic Operating Characteristics TRIP ALARM Q. CONNECTORS (1.23) Curve KM Magnetic Type Typical 26.2 21.1 100 (1.03) time/current characteristics Ambient Temperature 30C (0.83) at 30C 5.5 10 (0.22) Additional trip curves and amp ratings are available 1 upon request. 10 AUX SWITCH Q. CONNECTORS 1 7 0.1 (0.28) 10.7 21.3 0.01 (0.42) 32.9 (0.84) (1.3) 0.001 (%) Rated Current 4 Tripping Time Seconds Minutes 100 105 125 150 200 300 400 500 1000 1500 2000 2500 3000 4000 5000 57.0 (2.24) 11(C) (N/O)16 (N/C)18 12(N/C) (C)15 14(N/O) 2 2.8 (0.11) (0.08) 0.5 0.5 (0.02) (0.02)